Stations: 02 (2 Stations), Piping: D (U Side: Closed; D Side: Open), Thread Type: N (NPT), Supply Unit Components: S (w/Flow Adj. Valve; Stop Valve: None), Return Unit Flow Switch: 7 (Integrated Display), Return Unit Flow Range: 20 (2 to 16 L/min), Return Unit Components: P (w/o Flow Adj.
Body Size: 2 (1/8, 1/4), Type: 2 (Elbow), Control Type: 0 (Meter-out), Control Range: FSM (1 to 50 mm/s), Indicator Window Direction: 2 (90°), Thread: N (NPT), Port Size: 02 (1/4), Width Across Flats [H]: 9mm or None for Body Size 2, Tube Size: 09 (ø5/16), Sealant: S (with Sealant)
fluidDetection typeRated flow rangeOperating pressure rangeProof pressureOperating fluid temperatureLinearity Note 1)Repeatability Note 1)Temperature characteristicsOutput Note 2)specificationsPower supply voltageCurrent consumption (No load)ResistanceWeight Note 3)Port size (Rc, NPT, G)PF2A550Air, NitrogenHeater type5 to 50 l/min?
2% F.S. or less (15 to 35C, based on 25C)?3% F.S. or less (0 to 50C, based on 25C)Analog voltage output (non-linear) output impedance 1 k output for display unit PF2A3Voltage output 1 to 5 V (within the flow rate range)Linearity: ?5% F.S. or less; allowable load resistance: 100 k or more.Current output 4 to 20 mA (within the flow rate range)Linearity: ?
Stations: 10 Stations, Port Size: 02 (Rc1/4), Thread Type: T (NPTF), Kit Name: SDZEN (EtherNet/IP), SI Unit COM: N (-COM), Number of Input Blocks: 2 (Input Block 2 pcs.), Input Block: 2 (M12, 4 Inputs)
Body Size: 2 (1/8, 14), Type: 2 (Elbow), Control Type: 0 (Meter-out), Model: 1FS, Thread: N (NPT), Port Size: 02 (1/4), Width Across Flats: 9 mm (or None: Sizes 2/3/4), Applicable Tubing: 04 (ø4), Seal: S (with Sealant)
Body Size: 2 (1/8, 14), Type: 2 (Elbow), Control Type: 0 (Meter-out), Model: 1FS, Thread: N (NPT), Port Size: 02 (1/4), Width Across Flats: 9 mm (or None: Sizes 2/3/4), Applicable Tubing: 06 (ø6), Seal: S (with Sealant)
Series: 25A-PFM7, Flow Rate Range: 11 [2 to 100 (50) L/min], Port Size: 02 (Rc1/4), Piping Entry Direction: Straight, Output Specification: A (2 NPN Outputs), Unit Specification: M (Fixed SI Unit), Operation Manual: With Instruction Manual, Calibration Certificate: None, Connector: W (Lead Wire w/Connector, 2 m; Rubber Cover for Connector, Silicon Rubber), Option: R (Bracket for w/o Flow
Body Size: 2 (1/8, 1/4), Type: 2 (Elbow), Control Type: 1 (Meter-in), Control Range: FSM (1 to 50 mm/s), Indicator Window Direction: 0° , or None for FC, FM, Thread: R, Port Size: 02 (1/4), Width Across Flats [H]: 9mm or None for Body Size 2, Tube Size: 10 (ø10)
Rated Pressure Range: H (-0.1 to 2 MPa), Output Specification: Y (PNP Open Collector 2 Outputs + Copy Function), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: 02 [R1/4, (M5, Female Threaded)], Piping Direction: L (Bottom Ported), Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof), Bracket: A3 (Bracket C)
Body Size: 2 (1/8, 1/4), Type: 2 (Elbow), Control Type: 0 (Meter-out), Thread Type: N (NPT), Port Size: 02 (1/4), Dimension, Across Flat [H]: Body Size 1: 9mm; Body Size 2, 3, 4 None, Applicable Tubing O.D.: 11 (Ø3/8), Seal Method: S (with Sealant)
: 2 (ø1.0), 1st Selection Supply Valve and Release Valve: K (N.C.
Type of Actuation: 2 (2 Position Double), Manifold Type: 20 (Body Ported), Pilot: Internal Pilot, Specifications: Standard, Voltage: 5 (24VDC), Electrical Entry: WAO [M8 Connector w/o Connector (IEC60947-5-2)], Lead Wire Length: None, Surge Suppressor: Z (Light & Surge Suppressor), Manual Override: Non-locking Push Style, Port Size: 02 (Body Ported 1/4, Base Mounted Sub-plate 1/4), Thread
Type of Actuation: 2 (2 Position Double), Manifold Type: 20 (Body Ported), Pilot: Internal Pilot, Specifications: Standard, Voltage: 5 (24VDC), Electrical Entry: WAO [M8 Connector w/o Connector (IEC60947-5-2)], Lead Wire Length: None, Surge Suppressor: Z (Light & Surge Suppressor), Manual Override: Non-locking Push Style, A, B Port Size: 02 (Body Ported 1/4)
Body Size: 2 (1/8, 14), Type: 2 (Elbow), Control Type: 0 (Meter-out), Model: 1FS, Thread: N (NPT), Port Size: 02 (1/4), Width Across Flats: 9 mm (or None: Sizes 2/3/4), Applicable Tubing: 08 (ø8), Seal: S (with Sealant)
Flow Rate Range: 11 [2 to 100 (50 for CO2) â„“/min], Flow Adjustment Valve: None, Port Size: 02 (Rc1/4), Piping Entry Direction: Straight, Output Specification: 2 [Analog Output (4 to 20 mA)], Instruction Manual: With Instruction Manual, Calibration Certificate: A (w/Calibration Certificate), Connector: Lead Wire w/Connector (2 m), Option: R (Bracket for w/o Flow Adjustment Valve: ZS-33-M
Speed controller with one-touch fittings , Body sizes: M3, M5, 1/8, 1/4, 3/8, 1/2 , Maximum operating pressure 1MPa, Meter in or meter out control , Port sizes: M3, M5, U10/32, 01, 02, 03, 04 , Various tube O.D. in both metric and inch, FLOW CONTROL W/FITTING *LQA, AIRLINE EQUIPMENT, AS***F 1/2INCHSTANDARD (NPT), .21958 lb
6)2 to 10 stations: W = 22n + 11811 to 20 stations: W = 22n + 140
6)2 to 10 stations: W = 22n + 11811 to 20 stations: W = 22n + 140
6)2 to 10 stations: W = 22n + 11811 to 20 stations: W = 22n + 140