Description Qty 1 Rod cover 1 2 Head cover 1 3 Cylinder tube 1 4 Piston rod 1 5 Piston 1 6 Cushion ring 1 7 Cushion ring B 1 8 Bushing 1 9 Cushion valve 2 10 Tie-rod 4 11 Retaining ring 2 12 Spring washer 8 13 Tie-rod nut 8 14 Wear ring 1 15 Cushion seal 2 16 Rod seal 1 17 Piston seal 1 18 Cushion valve seal 2 19 Cylinder tube gasket 2 20 Piston gasket 1 21 Rod end nut 1 22 Magnet (1) 25
Part name Qty (1) Electric Actuator / LEF Series 1 (2) Driver / LECS Series 1 (in case with driver) (3) Motor cable 1 (in case with cable) (4) Encoder cable (5) Lock cable (6) I/O Connector 1 (in case with I/O connector) (2) Driver *2 1 (3) Motor cable (4) Encoder cable (5) Lock cable 24VDC Host controller, (1) Electric Actuator etc (6) I/O connector 2 *1 This picture is LECSA *2 The shape
A 1-B 1-C 2-A 2-B 1-C 2-B 1-C 2-B 1-C 2-B 1-C 2-B 1-C 2-B 1-C 2-B 1-C 2-B 1-C 2-B 1-C 2-B 2-B 2-B 1-A 1-B 1-C 2-A 2-B 1-C 2-A 2-B 2-B 2-B 2-B 2-B 1-A 1-B 1-C 2-A 2-B 2-B 2-B 2-B 2-B 2-B CE2 6 1/8, 1/4 1.5 500 0 1,000 2,000 3,000 ML2B Max. speed Vmax (mm/s) 6 1/4, 3/8 3 1000 Graph 3:25 ML1C 10 1/4, 3/8 20 (1/4) 4.5 1500 20 10 1/4, 3/8 REA Composed effective area So (mm2) Composed effective
8 Rc 1/8 Rc 1/4 Rc 1/4 M5 x 0.8 For use in Japan Port size NPT 1/8 NPT 1/8 NPT 1/4 NPT 1/4 For use in U.S.A.
direction 01 1 station Solenoid on same side of A and B port A port: Rc 1/8 B port: Rc 1/8 Nil P port: Rc 1/8 Thread type R port: Rc 1/8 20 Type S42 Solenoid on same side of A and B port 20 stations Type VK334 Nil F N T Rc S Port size Type VK3140 G P port: Rc 1/8 1 8 01 Rc C6 6 cassette NPT R port: Rc 1/8 NPTF B port: Rc 1/8 A port: Rc 1/8 Common SUP/Individual EXH Type 21: Body ported (
ML2B C J G5-S Applicable Auto Switch/Refer to page 10-20-1 for further information on auto switches.
They are all important notes for safety and must be followed in addition to International Standards (ISO/IEC)*1) , and other safety regulations. *1) ISO 4414: Pneumatic fluid power -General rules relating to systems. ISO 4413: Hydraulic fluid power -General rules relating to systems. IEC 60204-1: Safety of machinery -Electrical equipment of machines .
Vacuum pads are excluded from this 1 year warranty. Vacuum pads are excluded from this 1 year warranty. Vacuum pads are excluded from this 1 year warranty. Vacuum pads are excluded from this 1 year warranty. Vacuum pads are excluded from this 1 year warranty. A vacuum pad is a consumable part, so it is warranted for a year after it is delivered.
Modular Type Lubricator Series AL Lubricator Series AL Model Accessory Port size AL10 M5 x 0.8 1/8, 1/4 AL20 1/4, 3/8 AL30 AL40 1/4, 3/8, 1/2 Bracket AL40-06 3/4 AL50 3/4, 1 AL60 Pages 50 through 54 1 49 Lubricator AL10 to 60 How to Order AL 2R 30 03 B F Optional specifications Lubricator Symbol 1 10 11 2 3 6 8 C R 3W Z Description 1000cm3 tank 1000cm3 tank with level switch (lowest limit
Model AM850 AM250 AM350 AM450 AM550 AM650 AM150 Rated flow (l/min (ANR)) 750 1500 2200 3500 6000 12000 300 (1) Port size (Nominal size B) 1/8 ,1/4 ,3/8 1/4 ,3/8 ,1/2 3/8 ,1/2 ,3/4 1/2 ,3/4 ,1 3/4 , 1 1, 11/2 11/2 , 2 0.38 0.55 0.9 1.4 2.1 4.2 10.5 Weight (kg) Note 1) Max. flow capacity at a pressure of 0.7MPa. It varies depending on operating pressure.
No.CE*-OMI0063-C / / CE1* Series 1. 16 2. 7 2-1. 7 2-2. 78 2-2-1. 7 2-2-2. 8 2-2-3. 8 2-3. 9 3. 3-1. 10 3-2. 10 3-3. 11 3-3-1. 11 3-3-2. 11 3-3-3. 11 4. 4-1. 12 4-2. 12 4-3. 12 5. 5-1. 13 5-2. 14 5-3. 14 6. 6-1. 1516 6-2. 16 CE1B12 17 CE1B20 18 CE1B32 19 CE1B40 20 CE1B50 21 CE1B63 22 CE1 Series/ 1. 1) (ISO/IEC)(JIS) 2) *1) ISO
Leakage Worn spool packing (5) Intrusion of foreign matter (11) Spool valve has not completely shifted. (1),(7) Poor seal on actuator (cylinder, etc.) side (12) (13) Air leaks throuth gasket. Insufficient bolt tightening Air leaks through EXH.
Nil 6 50, 100, 150, 200 1 pc.
Assembly of Optional parts 11 8. Troubleshooting 12 9. How to Replace the Components 13 to 14 9-1. Bowl assembly Replacement 13 9-2. Element Replacement 14 10. Disassembly Drawing 15 11. Dimensions 16 -1- Activated Carbon Filter Safety Instructions These safety instructions are intended to prevent hazardous situations and/or equipment damage.
Connect no.1 and no.2 terminals with corresponding power side. Caution Ground (2) (1) Ground Terminal No. Internal w iring 1 Sol. A side 2 Sol.
11 K 8.4 8 10.5 10.5 13 13 L 40 53 70 70 90 90 M 2.3 2.3 2.3 2.3 3.2 3.2 AL10 AL20 AL30 AL40 AL40-06 AL50 AL60 M5 x 0.8 1/8, 1/4 1/4, 3/8 1/4, 3/8, 1/2 3/4 3/4, 1 1 25 40 53 70 75 90 95 Optional specifications Metal bowl B 82 121 142 176 176 250 268 Model Metal bowl with level gauge B 162 196 196 270 288 Metal bowl with drain cock & level gauge B 186 220 220 294 312 With drain cock
(UL standard V-0) Applicable model: ASV310F, ASV410F, ASV510F Inch size Note) Elbow: M3, M5 only Port size AS 04 06 08 10 12 03 07 09 11 13 M3 M5 U10/32 01 02 03 04 4 6 8 10 12 5/32" 1/4" 5/16" 3/8" 1/2" M3 x 0.5 M5 x 0.8 10-32 UNF 1/8 1/4 3/8 1/2 With One-touch fitting Thread type ASP Brass parts are all electroless nickel plated.
steel 12 to 40: Quenched/Hard chrome plated Nickel plated Alloyed steel Hexagon socket head set screw Piston seal Spline seal Collar gasket 1 1 Stainless steel 8 to 16 Black zinc chromated Alloyed steel 7 Cushion bolt 1 1 Carbon steel 20 to 40: Zinc chromated NBR 8 9 10 11 12 13 14 End lock bolt Collar Spline nut Cushion needle Cap Lock piston Lock spring 1 1 Carbon steel Quenched/Zinc chromated
Drain outlet One-touch fitting ([Thread symbol: N] 1/2 inch [Thread symbol: Nil] 12 mm) Earth leakage breaker (Inside of front panel) Power cable outlet ( Electric wire diameter: IDFB60/70: 0.35 to 0.43 in (9 to 11) ) IDFB80/90: 0.71 to 0.91 in (18 to 23) IDFB60-11: Power cable with plug [Length: 110 inch (2.8 m)] 8 B IDFB Series Specific Product Precautions 1 Be sure to read this before