M2 M3 m1 m2 m3 16 25 40 16 25 40 7 6 7 15 13 13 MY2H 28 26 26 32 30 30 60 50 60 62 62 62 46 55 46 20 18 18 100 120 100 38 35 35 MY2HT 200 220 200 80 80 80 The above values are the maximum allowable values for moment and load. Refer to each graph regarding the maximum allowable moment and maximum allowable load for a particular piston speed.
52 35 14 9 M10 x 1.5 69 5 24 18 40 5.5 M6 x 1.0 9 Rc1/8 26 14 10 5.5 7 4.5 57 14 40 118.5 96.5 16 35 64 37 14 12 M10 x 1.5 86 7 30 22 50 6.6 M8 x 1.25 11 Rc1/4 30 17 14 3 8 5.5 71 19 50 45 M16 x 2.0 84 130 102 21 77 39.5 16.5 15 103 7 36 28 60 9 M10 x 1.5 14 Rc1/4 36.5 21.5 18 4.5 10.5 6.5 19 63 9 3 Position Cylinder Series RZQ Foot type/RZQL Foot type (mm) B + Full stroke L Bore size (
Note 28) Selected bar (high voltage power supply module) ION/HV to display is turned off. Note 29) Selected bar (high voltage power supply module) stops the ion generation. 2)Changing to the setting mode For IZT41-L/42-L, refer to the IO-Link dedicated instruction manual.
FB G GA GB H J JC K L MM ML NN 12 (10 x 2) 10, 20, 30, 50, 100 33 24.5 6 6.5 2 17 11 5.5 58 8.5 1.5 8.5 11 M3 x 0.5 7.5 M2.5 x 0.45 16 (12 x 2) 33 24.5 6 6.5 2 18 11 5.5 64 9 3 9 11 M4 x 0.7 10 M3 x 0.5 Bore size OA OB OL P PD PE PW Q R S T U VA WA X YY YL Z 12 (10 x 2) 3.4 6.5 2.5 M3 x 0.5 6 16 18.5 8 26 14 49.5 39 52 10.2 23 M4 x 0.7 6 4.2 16 (12 x 2) 3.4 6.5 2 M3 x 0.5 6.5 16 18.5 8 28
Fluid name Applicable element Air (Dry) Lubricating oil (20 mm2/s) Industrial water Fragrances (1 mm2/s) Nominal filtration accuracy (m) Cotton Polypropylene Paper Micromesh Applicable filter model 0.5 Note 1) 10 Note 1) 1 5 10 20 10 5 FGDCA 110 550 11 21 23 26 22 29 03 FGDEA 110 750 12 27 30 36 28 42 04 FGDTA 110 1000 13 32 36 46 32 57 06 FGDFA FGDCB 200 600 17 25 26 28 26 30 03 FGDEB 200
28 28 28 28 Port size Weight (kg) E 47 47 52 58 58 63 G 9 9 9 9 9 9 9 9 Z 2.8 2.8 2.8 5.3 5.3 5.4 1/2B (04) 3/4B (06) 1B (08) 1 1/4B (10) 1 1/2B (12) 2B (16) 2 1/2B (20) 3B (24) 1/2B (04) 3/4B (06) 1B (08) 1 1/4B (10) 1 1/2B (12) 2B (16) 1/2 3/4 1 1 1/4 1 1/2 2 22.2 27.7 34.5 43.9 49.1 61.1 77.1 90.0 2.7 2.7 2.7 5.1 5.1 5.0 10.3 10.3 1/2B (04) 3/4B (06) 1B (08) 1 1/4B (10) 1 1/2B (12) 2B
Carbon steel Carbon steel Chromated 22 Tie-rod nut Sensor case gasket 8 NBR Carbon steel Chromated 23 Seal ring Piston seal 9 NBR Aluminum alloy White anodized 24 Centering location ring Scraper 10 NBR Aluminum alloy White anodized 25 Rod end pin Tube gasket 11 NBR Stainless steel Quenched 26 Sensor unit Rod seal 12 With or without connector NBR 27 Wear ring O-ring 13 NBR Special resin 28
Applicable load Type 2-wire 3-wire Solid state auto switch Auto switch model D-M9B(V) D-M9N(V) Load voltage 24 VDC (10 to 28 VDC) 28 VDC or less 5 to 40 mA 40 mA or less Load current range Indicator light Yes Yes 24 VDC relay, PLC PLC: Programmable Logic Controller Refer to page 946 for the applicable auto switches list.
30.5 37.5 KK 15 16 17.5 O 69 84 102 PP 56 62.5 77 NN 22 26 37.5 PA Rc 1/8 Rc 1/8 Rc 1/4 MM 16 21.5 24.5 LL 28 30.5 37.5 KK 15 16 17.5 NN 22 26 37.5 Applicable cylinder ML2B25 ML2B32 ML2B40 Applicable cylinder ML2B25 ML2B32 ML2B40 RS H A RZQ MI W S Stroke Adjusting Unit CEP1 With shock absorber: CE1 ML2B Bore size S Stroke L CE2 TT h ML2B EB FF EA Stroke adjusting unit C J G5-S CV ED MVGQ
30.5 37.5 KK 15 16 17.5 O 69 84 102 PP 56 62.5 77 NN 22 26 37.5 PA Rc 1/8 Rc 1/8 Rc 1/4 MM 16 21.5 24.5 LL 28 30.5 37.5 KK 15 16 17.5 NN 22 26 37.5 Applicable cylinder ML2B25 ML2B32 ML2B40 Applicable cylinder ML2B25 ML2B32 ML2B40 RS H A RZQ MI W S Stroke Adjusting Unit CEP1 With shock absorber: CE1 ML2B Bore size S Stroke L CE2 TT h ML2B EB FF EA Stroke adjusting unit C J G5-S CV ED MVGQ
size (mm) A LH LS B L LD LG 32 30 107.7 82.5 18 6.6 4 66.5 Special cap bolt 40 33 92 76 117.2 18 6.6 4 50 39 96.5 73.5 126.7 22 9 5 LY RE A B 63 46 102 76 138.2 28 11 5 LH REC Bore size (mm) LX LY LZ X Y X Y X Y LS Full stroke LG CX LZ LX 4-LD 32 57 57 71 11.2 5.8 A + Full stroke 40 64 64 78 11.2 7 CY 50 79 78 95 14.7 8 63 95 113 16.2 9 91.5 MQQ M Courtesy of Steven Engineering, Inc.-230
(Example) CUJ-M3 x 27l A A C B B D Axial mounting style Lateral mounting style Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Without Auto Switch For Axial Mounting For Lateral Mounting B 21 23 25 27 22 24 26 28 33 22 24 26 28 33 38 22 24 26 28 33 38 Model Mounting
32 L 250 290 LD 11 14 LH 57 65 LL 87 100 LW 168 200 M 15 16 N 47 50 NC 44 60 NE 122 147 NH 60 70 Bore size (mm) 50 63 SS 10 13 NW 118 142 PA 120 140 PB 186 220 PG 10 12 PP 26 42 Q 380 436 QQ 28 30 QW 90 110 RR 35 49 TT 35 43 UU 24 28 VV 28 30 W 200 236 WW 22 25 YW 128 152 Z 424 490 Bore size (mm) 50 63 Hole Size for Centralized Piping on the Bottom (Mounting side should be machined to these
No.PF-OMO0007CN / / PF2A7## 2 10 12 13 15 15 16 17 19 20 21 22 25 F_1 26 F_2 () 27 F_3 28 30 31 32 32 34 35 35 37 38 40 -1No.PF-OMO0007CN (ISO/IEC)(JIS) 1) 2) 1) ISO 4414: Pneumatic fluid power -General rules relating to systems ISO 4413: Hydraulic fluid power -General rules relating to systems IEC 60204-1: Safety of machinery -Electrical equipment of machines (
*2P7t *3P.26 7-3-6 28 ( / MIN50m sec(*2) + + (*1) (*1) END (*1) ) )END *10.2secMax. *2P.26 7-3-6 29 ( / MIN50m sec(*2) + + (*1) (*1) END (*1) () ) RUN *10.2secmax.
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 60
(P.28, 4) Short Long 1 3 5 Appropriate tightening torque for tie-rod nuts Tube I. D. Width across Appropriate tightening torque [Nm] flats 32, 40 6 5.1 50, 63 8 11.0 2 4 80,100 14 15.2 to 21.1 Tie rod tightening order. Fig.10 Tightening of tie-rod nuts 25 - 4-4-2.
(ZS-28-C-1) -13No.D-S-OMG0006-C Installation / Removal of the sensor connector to the amplifier unit When connecting the connector, insert it straight into the socket until the connector clicks.
Hence 28 - External stopper When the kinetic energy where the load is generated exceeds a permissible kinetic energy of the actuator, it is necessary to install the shock-absorbing mechanism outside and to absorb inertia force. There is backlash of the gear because the CRA1 series is a single rack type. (It is within 1 at the r otation end.)
structure and parts description 20 Rotary Actuator with solenoid valve internal structure 20 Mounting 21 Restriction of the load 21 Operation of shaft couplings 21 Piping and operating direction 22 Operating air 22 Setting rotation time 23 Moment of inertia 23 Table fir calculation of Inertia moment 24 Kinetic energy 25 External stopper 26 Calculation of required torque 27 Type of auto switch 28