SMC Corporation of America
Elite Part Number Search
Search Results "ISE20B-V-P-N01-A2"

Rated Vacuum Range: -100 to 100 kPa, Output Specification: PNP Open Collector 2 Outputs + Analog Current Output, Unit Specification: Unit Selection Function, Initial value psi, Piping Specification: NPT 1/8, Lead Wire: -, Bracket: -, Operation Manual: -

Rated Vacuum Range: -101 to 0 kPa, Output Specification: PNP Open Collector 2 Outputs + Analog Current Output, Unit Specification: Unit Selection Function, Initial value psi, Piping Specification: NPT 1/8, Lead Wire: -, Bracket: -, Operation Manual: -

Output Specification: PNP Open Collector 2 Outputs + Analog Current Output, Unit Specification: Unit Selection Function, Initial value psi, Piping Specification: NPT 1/8, Lead Wire: -, Bracket: -, Operation Manual: -

Rated Pressure Range: -14.50 to 14.50 psi, Piping: NPT1/8, w/M5 Female Thread, Output Specification: PNP Open Collector 2 Outputs+Analog Current/Auto-shift Switching, Unit Specification: Unit Switching Function, Initial Value psi; Not Allowed for Use in Japan, Option: -, Calibration Certificate: -, Lead Wire: -

Rated Pressure Range: 0.00 to -14.69 psi, Piping: NPT1/8, w/M5 Female Thread, Output Specification: PNP Open Collector 2 Outputs+Analog Current/Auto-shift Switching, Unit Specification: Unit Switching Function, Initial Value psi; Not Allowed for Use in Japan, Option: -, Calibration Certificate: -, Lead Wire: -

Piping: NPT1/8, w/M5 Female Thread, Output Specification: PNP Open Collector 2 Outputs+Analog Current/Auto-shift Switching, Unit Specification: Unit Switching Function, Initial Value psi; Not Allowed for Use in Japan, Option: -, Calibration Certificate: -, Lead Wire: -

Blue (DC(-)) 3 Blue (DC(-)) Other Settings Black (OUT: 4 to 20 mA) 4 Black (OUT: 1 to 5 V) Blue (LINE(-)) Auto shift [Default setting] Auto shift zero Mounting and Installation Check that the above preparation has been performed correctly, then part A shown should be pressed in by hand to make temporary connection.

The ISE2 series is a compact, pressure switch (for positive pressure) and can be integrated with ZX or ZR vacuum systems. The ISE2 series pressure switch has a quick response time of 10mS and the plug connector option makes wiring easy and simple., DIGITAL PRESSURE SWITCH, PRESSURE SWITCH, ISE1-6, N59, 75 lb

Bore size (mm) 125 140 160 180 200 250 300 Refer to p.1.10-7 for How to Order Auto Switches Style.

MS-5ALHU-3 MS-5P H/DL L/LL For polyurethane tube 3.18/2 x M5 P.339 KC Extention fitting Solid piece moves fitting up from work piece M5 male x M5 female 4/2.5 x M5 MS-5J MS-5ALHU-4 KK For soft nylon and polyurethane tube P.339 KK130 Nipple Fitting to workpiece and fitting to fitting connection M5 male x M5 male 6/4 x M5 MS-5N MS-5ALHU-6 DM P.338 P.339 KDM Universal nipple Hose nipple Body

Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: P [Units Selection Function (Initial Value psi)], Under New Measurement Act Selection Function not Permitted for use in Japan, Piping Specification: M5 (Female Thread), Lead Wire: W (Lead Wire w/Connector, 5-core, 2m Lead Wire w/Waterproof Cover), Bracket: A2 [Bracket B, Horizontal Mounting (ZS-46-A2)]

Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: P [Units Selection Function (Initial Value psi)], Under New Measurement Act Selection Function not Permitted for use in Japan, Piping Specification: 01 (R1/8), Lead Wire: w/o Lead Wire, Bracket: A2 [Bracket B, Horizontal Mounting (ZS-46-A2)], Operation Manual: T (w/o Operation Manual, Calibration Certificate)

Dimensions/Socket (S) Male thread type A2 A1 T D H L1 L2 (mm) A1 A2 Effective area mm L2 Body size H Width across flats T Connection male thread Minimum bore Model D Weight g When When L1 connected connected KKH3S-01MS R1/8 33.5 20.4 20.4 6 36 18.2 14 1/8 40 37.5 KKH3S-02MS R1/4 31.5 19.5 21.1 9 34 KKH4S-01MS R1/8 54.1 50.4 46.4 48.8 22.9 6 50.1 KKH4S-02MS R1/4 54.7 51 19 45 45.4 38.9 9 48.7

Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: P [Units Selection Function (Initial Value psi)], Under New Measurement Act Selection Function not Permitted for use in Japan, Piping Specification: Female Thread, Lead Wire: Lead Wire w/Connector, 5-core, 2m Lead Wire w/Waterproof Cover, Bracket: A2 [Bracket B, Horizontal Mounting (ZS-46-A2)], Operation Manual

Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: P [Units Selection Function (Initial Value psi)], Under New Measurement Act Selection Function not Permitted for use in Japan, Piping Specification: R1/8, Lead Wire: w/o Lead Wire, Bracket: A2 [Bracket B, Horizontal Mounting (ZS-46-A2)], Operation Manual: w/o Operation Manual, Calibration Certificate

Rated Vacuum Range: -101 to 0 kPa, Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: P [Units Selection Function (Initial Value psi)], Under New Measurement Act Selection Function not Permitted for use in Japan, Piping Specification: NPT1/8, Lead Wire: Lead Wire w/Connector, 5-core, 2m Lead Wire w/Waterproof Cover, Bracket: A2 [Bracket B (ZS-46-A2)], Operation

Rated Vacuum Range: -100.0 to 100.0 kPa, Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: P [Units Selection Function (Initial Value psi)], Under New Measurement Act Selection Function not Permitted for use in Japan, Piping Specification: NPT1/8, Lead Wire: Lead Wire w/Connector, 5-core, 2m Lead Wire w/Waterproof Cover, Bracket: A2 [Bracket B (ZS-46-A2)], Operation

Rated Vacuum Range: -100.0 to 100.0 kPa, Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: P [Units Selection Function (Initial Value psi)], Under New Measurement Act Selection Function not Permitted for use in Japan, Piping Specification: Female Thread, Lead Wire: Lead Wire w/Connector, 5-core, 2m Lead Wire w/Waterproof Cover, Bracket: A2 [Bracket B (ZS-46-A2