45 17 36 82.6 2 x 3/4, 1, 1 1/4 (IN, OUT port) 95 Note) External pilot port (PA port) 1/4 is processed for threads in external pilot model only.
Vibration resistance allows for normal operation up to 30 m/s2 (45 to 250 Hz), but continuous vibration may cause a decline in durability. Arrange piping to avoid excessive vibrations or shocks. I High-temperature type (H0, H4, H5) 1. For models with a heater, take care not to damage the insulation components of the lead wires and the connector section. 2.
(NA) (NA) Q + Stroke Data d Bore size (mm) Standard stroke (mm) A PA (N) (NA) PB PW Q E F G GP H HG HN HP HT L Slide Ball bushing 32 25, 50, 75, 100 10.5 28 20 45 27 9.5 110 66 26.5 67.6 64 33.5 100 14 53 70 120 160 121 40 25, 50, 75, 100 11.5 36 25 52 31 10.5 130 78 30.5 77.6 74 40.5 136 12 51 90 140 190 159 PA dimension is the center sorted factor of the L dimension.
0.2 stroke 133 36 184 Up to 1400 1401 to 1600 612 0.2 stroke 141 45 204 Up to 1400 1401 to 1600 Not available with auto switches. 9-8-13 14 Series CNS Dimensions Rod side flange style (F): CNSF M Rc BQ plug with breathing hole BC element T GB GA (In the case of NPT port) FA 4-J 4-FD Rc BP Unlocking port 2-Rc P Cylinder port Width across flats KA GL GR G G MM Q D EA E FY BF V FT VA AL A
M1 M2 M3 m1 m2 m3 16 25 40 16 25 40 16 25 40 5 4 3.5 18 16 14 MY2H 13 14 10 35 35 30 45 33 28 68 66 57 7 6 7 15 13 13 MY2H 28 26 26 32 30 30 60 50 60 62 62 62 46 55 46 20 18 18 MY2HT 100 120 100 38 35 35 200 220 200 80 80 80 The above values are the maximum allowable values for moment and load.
Vibration resistance: No malfunction occurred in a test ranging between 45 to 2000 Hz. The test was performed in both an axial direction and a perpendicular direction to the lead screw.
Vibration resistance: No malfunction occurred in a test ranging between 45 to 2000 Hz. Test was performed in both an axial direction and a perpendicular direction to the lead screw. (Test was performed with the actuator in the initial state.) Note 9) The power consumption (including the controller) is for when the actuator is operating.
Before piping this product, exercise caution to prevent particles, water drops, or oil contents from entering the piping. 25 45 30 55 Static Neutralization Equipment 40 65 50 75 Wiring/Piping Warning 1. Confirm if the power supply voltage is enough and that it is within the specifications before wiring.
A B C D E EE F G H J K Applicable size Y200T-D 3.2 67 29 51 24 33 11.5 5.5 15.5 3.5 30 JSXM20 Y300T-D 4.2 85 42.5 67.5 35 14 7 20 6 41 JSXM30 Y400T-D 5.2 115 50 85.5 40 55 18 9 26 7 50 JSXM40 45 JSX10, 20, 30 Series Table of UL-compliant Products * Refer to the table below for UL-compliant products.
45 45 45 Drain guide port size 1/8 1/4 1/4 1/4 1/4 1/4 10-: Fluorine grease Grease 21-: Lithium soap based grease 10-: Class 3 Cleanliness class (ISO class) 21-: Class 3 Note 1) Inlet side pressure: 0.5 MPa, Pressure drop: 0.05 MPa (Representative value).
Terms Precautions SL AP Recommendations Regulators Wetted Parts Material H S Wetted Parts Body Surface finish Diaphragm Seat Hastelloy C-22 Electropolish 316L SS secondary remelt Electropolish + Passivation Elgiloy PCTFE (Option: Vespel) PCTFE Dimensions inch (mm) AP3500 1.37 (34.8) AP3550 1.46 (37.1) AP3540/3580 AP3540 3.49 (88.6) AP3550 3.28 (83.3) AP3580 3.17 (80.5) 0.44 (11.2) A B B 45
Specification 25 Specifications 25 Dimensions 26 End Plate Model Indication and How to Order 27 Summary of Product parts 28 Mounting and Installation 30 Wiring 30 Specification 32 Specifications 32 Dimensions 33 IO-Link Master Unit Model Indication and How to Order 40 Summary of Product parts 40 Mounting and Installation 41 Wiring 41 LED Display 42 Specification 44 Specifications 44 Dimensions 45
Theoretical Output OUT IN [N] Bore size [mm] Rod size [mm] Operating direction Piston area [mm2] Operating pressure [MPa] 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 12 6 OUT 113 23 34 45 57 68 79 90 102 113 IN 85 17 25 34 42 51 59 68 76 85 16 8 OUT 201 40 60 80 101 121 141 161 181 201 IN 151 30 45 60 75 90 106 121 136 151 20 10 OUT 314 63 94 126 157 188 220 251 283 314 IN 236 47 71 94 118 141 165
Applicable cylinder ML2B25 ML2B32 ML2B40 MY-S25A 35 50 8 5 9.5 5.5 M6 x 1 B MY-S32A 45 64 11.7 6 11 6.6 M8 x 1.25 B Guide for Side Support Application For long stroke operation, the cylinder tube may be deflected depending on its own weight and the load. In such a case, use a side support in the middle section.
Wear ring O-ring 13 Special resin 27 NBR Bushing O-ring 14 Lead-bronze casting 28 NBR Since there is a possibility of improper operation, contact SMC regarding the replacement of seals. 4 Series CEP1 12/Dimensions Direct mounting front tapped type CEP1B12 Stroke 4 depth 4 (Positioning pin hole) Cable end +0.05 +0.02 Without connector 40 4 depth 4 (Positioning pin hole) 17 +0.05 +0.02 4 45
MGQ Theoretical Force MGG (N) MGC IN OUT Cylinder bore size (mm) Operating pressure (MPa) Operating direction Piston area (mm2) 0.7 0.5 0.3 MGF 84.8 IN 59 42 25 12 113 OUT 79 57 34 CY1 151 IN 106 75 45 16 201 OUT 141 101 60 MY1 236 IN 165 118 71 20 314 OUT 220 157 94 378 IN 264 189 113 25 491 OUT 344 245 147 603 IN 422 302 181 32 804 OUT 563 402 241 1056 IN 739 528 317 40 1257 OUT 880 628
and MDHR Regardless of auto switch installation, some body dimensions are different. 2-M3 x 0.5 thread depth 6 (Thread for mounting attachment) A 12 12 B A 5 4.7 B 14.5 14.5 15.5 15.5 Model -10R -10E -10R -10E MHR2 MDHR2 4 4 4 4 12-5-11 12 Series MHR2/MDHR2 Nominal Size 15 Without auto switch: MHR2-15R 3-M3 x 0.5 thread depth 6 P.C.D.29 (Mounting thread) 44 42 MHR2-15E Port Location B 45
MHK 5 15.7 4.7 3.5 MHS 2-3 12 41.5 (45) 8 2-4.2 17 MHC2 15.5 8 0 -0.05 2 MHT2 2 3.5 0 -0.03 3.5 0 -0.03 MHY2 Open: 22 Closed: 14 MHW2 2-M3 X 0.5 thread depth 6 (Thread for mounting attachment) MRHQ Auto switch 15 15 6 5 5 6 2.3-12 Series MHR2/MDHR2 20 Without Auto Switch: MHR2-20R 57 54 3-M4 X 0.7 thread depth 8 B MHR2-20E port position P.C.D36 (Mounting thread) 60 120 o 14 120o A C 45 M5
(Value in the initial state) Vibration resistance: No malfunction occurred in one sweep test between 45 and 2000 Hz. Test was performed to axis and right angle directions of the main valve and armature when pilot signal is ON and OFF.
type (Except for 6) Single clevis type (Non-integrated type) Double clevis type 10 15, 30, 45, 60, 75, 100 16 15, 30, 45, 60, 75, 100 20 15, 30, 45, 60, 75, 100 25 15, 30, 45, 60, 75, 100 Strokes are available in 1mm increments by installing spacers in standard stroke cylinders.