QA [mm] F 13 Tubing O.D. 6 B + Stroke R R 8 QB Stroke Q Bore size QA F Q QB QU QW 1.8 Stroke 20 Tubing O.D. QA F 13 KA KB Tubing O.D. 6 8 QB Stroke Q QU 32 6 7.5 20 13 38 60.5 40 6 8 24.5 13 42 68 50 8 9.5 26 16 50 82 29 1.8 Stroke 20 QW Tubing O.D. QA F 13 Tubing O.D. 6 QU 8 QB Stroke Q 29 1.8 Stroke 20 QW 32 to 50 20 Tubing O.D.
C = coupling, tube to tube L = elbow, barbs at 90 T = tee/ (-3) = (3 way tee) T90 = branches at 90 X = 4 way cross R = reducer RB = reducer bushing RC = reducer coupling RT = reducer tee RX = reducer cross A = adjustable BK = bulkhead F = female thread HN = hex nipple IRM = in-line reducer manifold M = manifold SW = swivel V = outlets at 60 C.
Function number Function name Default setting Page F 0 (Unit) Unit selection [ PA] kPa Page 49 ISA3-F: [ 20] ISA3-G: [ 50] ISA3-H: [ 50] Switch point ISA3-F: [ 3] ISA3-G: [ 20] ISA3-H: [ 20] F 1 (oUt1) OUT1 setting Page 50 Hysteresis Display colour [ SoG] Green when ON, Orange when OFF out2: [ Ewin] Output mode OUT port side pressure detection Window comparator mode Reversed output 2ot:
Pitch moment Yaw moment : Collision speed (mm/s) L1 : Distance to the center of load gravity (m) ME : Dynamic moment (Nm) g : Gravitational acceleration (9.8 m/s2) m : Load mass (kg) F : Load (N) FE : Load equivalent to impact (at impact with stopper) (N) a : Average speed (mm/s) M : Static moment (Nm) M1e = We x L3 x 1 3 M3e = We x L2 x 1 3 M1e M3e We We L3 At collision: = 1.4a a L2
Type of impact Cylinder stroke at load (Horizontal) RE A B Cylinder stroke at load (Horizontal) Cylinder stroke at load (Downward) Cylinder stroke at load (Upward) Conveyor stroke at load (Horizontal) Free dropping impact Rotating impact (With torque) REC Shock absorber 1.
Mounting at the back Mounting at the front Rear single clevis C Rear double clevis D Bore (mm) Z E1 R W MF ZF FB CD EB L XD UB CB EW MR TR AO AT XA SA AH AB L1 TL TD TM UW TF UF E2 48 55 68 80 100 120 32 36 45 50 63 75 16 20 25 25 30 35 10 10 12 12 16 16 130 145 155 170 190 205 7 9 9 9 12 14 10 12 12 16 16 20 65 75 80 90 110 140 12 15 15 20 20 25 142 160 170 190 210 230 45 52 60 70 90 110
Parameter Set value Initial value Note Fixed For the EXW1-RD#, the number is fixed at 16 (16 bits). * Although the number of occupied inputs of EXW1-RDM# is fixed at 16 (16 bits), only the lower 8 bits are available.
A when load is applied F Table deflection due to yaw moment load Displacement at A when load is applied F Table deflection due to roll moment load Displacement at A when load is applied F A A F A F F MX MTS L L L MY L dimension mm L dimension mm L dimension mm MXY6 MXY6 MXY6 100 100 100 CY MXY8 MXY8 MXY8 100 100 100 MXY12 MXY12 MXY12 140 140 140 MG Courtesy of Steven Engineering, Inc.-230
(Not including sensor accuracy), Response speed: 150 ms or less Resistance Weight Analog output 0.6% F .S. or less 1.0% F .S. or less 1.5% F .S. or less Accuracy (To display value) (25C) IS Output current: 4 to 20 mA (Within rated pressure range) Current output Note 2) Maximum load impedance: 300 (at 12 VDC), 600 (at 24 VDC), Minimum load impedance: 50 ZSM Linearity: 0.2% F .S.
Heat proof specification "-X4" 2 Grooves on both sides for auto switch "-X41" 4 Cylinder bore X4 F MHK D 1 L 2 MHK 2 L D 1 F Cylinder bore X41 Finger material Dust cover material Type of actuation Finger material Type of actuation Fluoro-rubber seals and special grease for use at high temperatures of up to 212F (100C). Additional switch mounting positions for installation flexibility.
DC voltage (with surge voltage suppressor) If the polarity is incorrect at DC (surge voltage suppressor), diode or switching element may be damaged.
Accelerating torque calculation (Example) (Example) Friction coefficient Ta = I x (Nm) Mass m F = mg Clamp F F I : Inertial moment Static torque calculation Movement Load Refer to features page 5. : Angular acceleration = (rad/s) Tf = F x l (Nm) g = 9.8m / s F: Pressing force (N) l l Static torque calculation 2 Load t2 Ts = F x l (Nm) Lever : Rotation angle (rad) t : Rotation time
The operation of the actuator should be confirmed at a low speed. Operate it at the prescribed speed only after proper operation is confirmed. 96 100 Series LTF Electric Actuator Precautions 2 Be sure to read before handling. Mounting Power Supply Caution Caution 1. Do not use until you verify that the equipment can operate properly. 2.
Refer to pages starting with 181 for mounting. 30 100 95 95 B 8(4)-6.2 (160) () () 110 95 20 95 A () () (140) A B 100 200 300 400 500 600 700 800 900 1000 1200 Stroke Model LG1H202SC-100-F LG1H202SC-200-F LG1H202SC-300-F LG1H202SC-400-F LG1H202SC-500-F LG1H202SC-600-F LG1H202SC-700-F LG1H202SC-800-F LG1H202SC-900-F LG1H202SC-1000-F LG1H202SC-1200-F 50 150 250 350 450 550 650 750 850 1050
Tubing material Nil Rc Locking direction n L Foot style TN NPT Nil Aluminum tube F Rod side flange style F Steel tube D Both directions G Head side flange style Auto switches are not available with steel tube.