F A A Lr MXF8 Lr = 20 mm 0.08 0.04 0.03 MXF8-30 Table displacement amount (mm) Table displacement amount (mm) Table displacement amount (mm) MXF8-30 0.06 MXF8-10 MXF8-20 MXF8-30 0.03 0.02 MXF8-20 0.04 0.02 MXF8-20 MXF8-10 0.01 0.02 0.01 MXF8-10 0 0 0 10 20 30 40 10 20 30 10 20 30 40 Load (N) Load (N) Load (N) MXF12 Lr = 30 mm 0.10 0.08 MXF12-50 0.06 Table displacement amount (mm) Table displacement
Dew point conversion chart 60 50 40 30 Pressure dew point C 20 10 1.5MPa 1.3MPa 1.1MPa 0.9MPa 0.7MPa 0.5MPa 0.3MPa 0.1MPa Atmospheric pressure 0 10 20 30 40 50 60 50 60 40 30 20 10 0 10 20 30 Atmospheric pressure dew point C 25 Series IDU/IDF Safety Instructions These safety instructions are intended to prevent a hazardous situation and/or equipment damage.
0.8 0.7 0.7 0.7 0.6 0.6 0.6 0.5 0.5 0.5 0.4 0.4 0.4 0.3 0.3 0.3 0.2 0.2 0.2 0.1 0.1 0.1 VY130-5 VY140-5 VY150-5 0 1 2 3 4 5 0 1 2 3 4 5 0 1 2 3 4 5 V V V VY130-6 VY140-6 VY150-6 1 1 1 0 2.5 5 7.5 10 0 2.5 5 7.5 10 0 2.5 5 7.5 10 V V V VY130-7 VY140-7 VY150-7 mA mA mA 4 0 8 12 16 20 4 0 8 12 16 20 4 0 8 12 16 20 2 2 2 VY130-8 0 5 10 15 20 VY140-8 0 5 10 15 20 VY150-8 0 5 10 15 20 3 3 3 mA
V) 1, 2 0 V 0.1 V 10 V Current output 1 4 mA 4.16 mA 20 mA Models Minimum value of rated flow range Maximum value of rated flow range PF2MC7501 5 L/min 500 L/min PF2MC7102 10 L/min 1000 L/min PF2MC7202 20 L/min 2000 L/min 1: Analogue output accuracy is within 3%F.S. 2: Set the current to the analogue output from the connected equipment to 20 A or less when selecting 0 to 10 V.
20 25 50 100 150 200 300 500 600 1000 2000 3000 6000 12000 0.2 PFM 0.01 L/min 10 Air N2 Argon CO2 0.5 25 Thermal type (MEMS) 0.1 L/min 1 50 2 100 PFMB 2 200 Thermal type (MEMS) 5 500 Dry air N2 1 L/min Bypass flow type 10 1000 20 2000 PFMC 5 500 Thermal type (MEMS) New New Dry air N2 1 L/min 10 1000 Bypass flow type 20 2000 PF2A 1 10 0.1 L/min 0.5 L/min 5 50 1 L/min 10 100 2 L/min 20 200
24.5 55 175 20 8 Front flange type: MQMLF 6 20 2.3 33 42 27.5 2-5.5 66 + Stroke 93.5 + Stroke 10, 16, 20, 25 FY FT FX FZ H 2-FC S + Stroke ZZ + Stroke (mm) Bore size (mm) FC FT FX FY FZ H S ZZ 10 5.5 2.3 33 20 42 28 65 101 16 5.5 2.3 42 24 54 30 74 114 20 7 4 60 34 75 40.5 97.5 151 25 7 4 60 40 75 44.5 102.5 160 14 Series MQM Refer to the basic type on page 13 for other dimensions.
For DC 10-V114-5LO SY100-30-4A-20 For AC 10-V114A-1LO SY100-30-1A-20 Crimping area Core wire crimping area Core wire Lead wire Socket 0.2 to 0.33 mm2 Max. cover diameter: 1.7 mm Hook Insulation 646 Series 10-V100 Specific Product Precautions 2 Be sure to read before handling.
V) 1, 2 0 V 0.1 V 10 V Current output 1 4 mA 4.16 mA 20 mA Models Minimum value of rated flow range Maximum value of rated flow range PFMC7501 5 L/min 500 L/min PFMC7102 10 L/min 1000 L/min PFMC7202 20 L/min 2000 L/min 1: Analogue output accuracy is within 3%F.S. 2: Set the current to the analogue output from the connected equipment to 20 A or less when selecting 0 to 10 V.
4 mA 4.16 mA 20 mA E F G Voltage output (0 to 10 V) 1 0 V 0.10 V 10 V 1: The analogue output current from the connected equipment should be 20 A or less when selecting 0 to 10 V.
MHL2-10D MHL2-16D MHL2-16D MHL2-10D 2 1 2 1 60 60 25 25 0.6MPa 0.6MPa Holding force (N) Holding force (N) Holding force (N) Holding force (N) 50 50 20 20 0.5MPa 0.6MPa 0.5MPa 0.6MPa 40 40 15 15 0.4MPa 0.5MPa 0.4MPa 0.5MPa 0.4MPa 0.4MPa 30 30 10 10 0.3MPa 20 20 0.3MPa 0.3MPa 0.3MPa 0.2MPa 5 5 10 10 0.2MPa 0.2MPa 0.2MPa 10 20 30 40 50 60 70 20 40 60 80 100 120 20 40 60 80 100 120 0 0 0 10 20
20 20 0.5 MPa 0.7 MPa 0.7 MPa 0.7 MPa 10 10 10 0 0 0 5 10 15 0 0 10 20 30 40 60 50 0 10 20 30 40 50 Flow rate [L/min (ANR)] Flow rate [L/min (ANR)] Flow rate [L/min (ANR)] ZFC33/3B 4, 5/32" ZFC53/5B 4, 5/32" ZFC54/5D 6, 1/4" 0.3 MPa 0.3 MPa 0.3 MPa 30 30 30 0.1 MPa Pressure drop [kPa] Pressure drop [kPa] Pressure drop [kPa] 0.1 MPa 0.1 MPa 20 20 20 0.5 MPa 0.5 MPa 0.5 MPa 0.7 MPa 0.7 MPa
20 15 15 10 10 5 5 0 0 5 10 15 20 25 30 35 5 10 15 20 25 30 35 Circulating fluid temperature [] Circulating fluid temperature [] 60Hz 50Hz Fig. 8-3: Cooling Capacity 8.5 Pump Capacity 0.6 60 Usable flow rate range 0.5 50 Circulating fluid outlet (60Hz) Lifting head [m] Pressure [MPa] 0.4 40 0.3 30 0.2 20 Circulating fluid outlet (50Hz) 0.1 10 Circulating fluid return 0.0 0 0 10 20 30 40
S n Nil Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 2 fingers 2 Number of fingers Bore size 10 mm 16 mm 20 mm 25 mm 32 mm 40 mm 10 16 20 25 32 40 Action D Double acting Opening/Closing stroke (mm) 10 16 20 25 32 40 30 60 80 Symbol Nil 20 40 60 40 80 100 50 100
Do not modify the internal electrical wiring of the product. 11.2 Earth leakage breaker specification Models Item IDF60-20-R IDF70-20-R IDF80-20-R IDF90-20-R Rated current (A) 10 15 20 30 Sensitivity current (mA) 30 Models Item IDF60-30-R IDF70-30-R IDF80-30-R IDF90-30-R Rated current (A) 10 15 20 Sensitivity current (mA) 30 IDF60/70/80/90 Series 11.1 Safety instructions for use 11-1 IDX-OM-V022
Mar Q QQ RQ SQ . ZQ AQ BQ . Feb P QP RP SP . ZP AP BP . May S QS RS SS . ZS AS BS . Aug V QV RV SV . ZV AV BV . Jan o Qo Ro So . Zo Ao Bo . Nov y Qy Ry Sy . Zy Ay By . 2012 2013 2014 . 2021 2022 2023 . Year Jun T QT RT ST . ZT AT BT . Dec Z Qz RZ SZ . ZZ AZ BZ . Apr R QR RR SR . ZR AR BR . Jul U QU RU SU . ZU AU BU . Month Q R S . Z A B . Oct X QX RX SX . ZX AX BX .
Stroke 5 10 15 20 25 30 5 mm 10 mm 15 mm 20 mm 25 mm 30 mm Applicable Auto Switch/Refer to page 8-30-1 for further information on auto switches.
, 10, 16 Standard stroke (mm) 5, 10, 15, 20, 25, 30 Refer to Minimum Stroke for Auto Switch Mounting on page 8-3-10.
ADH-E400 1.6MPa 0.051.6MPa 3/h 0.024m 0.7MPa IDF60/70/80/90 Series 10-1 IDX-OM-W093 L 10.3 Rc1/225 30 5 IDF60 2722IDF70IDF80IDF90 22 IDF60 (IDF70/80/90) 1) 2830Nm 2) 10.4 1 1 IDF60/70/80/90 Series 10-2 IDX-OM-W093 R 11 R R (GFCI) 11.1 11.2 IDF60-20-R IDF70-20-R IDF80-20-R IDF90-20-R (A) 10 15 20 30 (mA) 30 IDF60-30-R IDF70-30-R IDF80-30 IDF90-30 (A) 10 15 20 (mA) 30
, SiC 10, Carbon 10, PP 10 3-phase 380 to 415VAC(50/60Hz) Allowable voltage range 10%(No continuous voltage fluctuation) Power supply 3-phase 460 to 480VAC(60Hz) Allowable voltage range +4%,-10%(Max. voltage less than 500V and no continuous voltage fluctuation) Rated current A 40 Electrical system Applicable earth leakage breaker Sensitivity current mA 30 Rated operating current 5 A 22 Rated
A 4 A Power supply (Output) 24 VDC +10/-5%, 24 VDC +10/-5%, DC24 V +10/-5%, 2 A 8 A 4 A Enclosure IP67 (With manifold assembled) 1 Environment Operating temperature range -10 to 50 oC Storage temperature range -20 to 60 oC Operating humidity range 35 to 85%R.H.