67h9 32H9 12 22H9 10 4.5 3 6.5 17 8.6 14 8.5 85.4 80 10 38 22 19 6 15.5 63 37.5 100 50 10 37.5 75h9 77h9 35H9 13 26H9 12 5 3 7.5 20 10.5 18 10.5 (mm) JC JD JJ JU P Q S SD SE SF SU UU WA WB WC WD WE WF XA XB XC YA YB YC Size 10 20 30 50 M 8 x 1.25 12 M5 x 0.8 M 8 x 1 M5 x 0.8 34 92 9 13 45 17.7 47 15 3H9 3.5 M5 x 0.8 8 32 27 3H9 3.5 19 3H9 3.5 M10 x 1.5 15 M6 x 1 M10 x 1 M5 x 0.8 37 117 10
W or less 20 VA or less 10 W or less 20 VA or less 10 W or less 20 VA or less 10 W or less Between case and AC line: 1500 VAC for 1 min.
(mm) 02 04 06 08 10 13 16 20 25 32 40 50 2 4 6 8 10 13 16 20 25 32 40 50 Pad type 02 04 06 08 10 13 16 20 25 32 40 50 2 4 6 8 10 13 16 20 25 32 40 50 Pressure gauge position Thread dia.
MXP10-10 A Width across flats 1.5 H 13 (Plug: M-5P) 2-M5 x 0.8 Piping port Width across flats 5.5 4-M3 x 0.5 depth 4 6.5 16.4 M3 x 0.5 7 4 3.7 21 20 8.5 depth 2.5 3 4-M4 x 0.7 A 0.5 19 +0.030 0 depth 2.5 3 20 0.05 Prepared hole diameter 3.3 +0.030 0 15 W 0.50.05 B D 2-M5 x 0.8 Piping port M5 x 0.8 Vacuum suction port 28 27 10 4.5 depth 1.5 3 J 6 +0.030 0 10 9.5 4 Section AA Mounting base
MHR2-10/MDHR2-10 MHR2-10/MDHR2-10 20 20 Pressure 0.6 MPa Pressure Gripping force (N) Gripping force (N) 15 15 0.6 MPa 0.5 MPa MHZ 0.5 MPa 10 10 0.4 MPa 0.4 MPa MHF External grip 0.3 MPa 0.3 MPa 5 5 MHL 0.2 MPa 0.2 MPa MHR 0 10 20 30 40 50 0 10 20 30 40 50 Gripping point L (mm) Gripping point L (mm) MHK Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main
Applicable bore size A D L MM N R W Flat type Round type CJ-CF010 CJ-CR010 10 8 10 13 M4 x 0.7 6 10 8 Part no.
0.7 29 40 30 10 70 3.5 20.9 4 25 2.5 25 5 14 MXY12 M5 x 0.8 31 52 40 15 86 8.5 30.9 5 3 36 32 6 18 PH TB Z T WR RL QW R RH WE WD Q W PR P PL TH Model MXY6 5.1 2.9 88 4 12 60 5 7 30 11 13 3(depth 3) 3(depth 3) 2.5 9 20 25.5 MXY8 6.1 98 3.4 4 15 70 6.5 7 38 19 13 3(depth 3) 3(depth 3) 3 10 25 32 MXY12 7.8 114 4.5 21 5 8.5 90 7 50 29 18 4(depth 4) 4(depth 4) 4 13 33 42 n QL Model 50 100 150
M (Maximum allowable moment) (Nm) 0.68 30 x 10-3 Allowable load F (N) = Allowable load F = L x 10-3 ( Unit converted invariable number) = 22.7 (N) Load f = 10 (N) 22.7 (N) Therefore, it can be used. 12-3-7 8 Low Profile Air Gripper Series MHF2 Size: 8, 12, 16, 20 How to Order MHF 2 12 M9B D Number of auto switches Number of fingers 2 2 finger Nil S 2 pcs. 1 pc.
M (Maximum allowable moment) (Nm) 0.68 30 x 10-3 Allowable load F (N) = Allowable load F = L x 10-3 ( Unit converted invariable number) = 22.7 (N) Load f = 10 (N) 22.7 (N) Therefore, it can be used. 12-3-7 8 Low Profile Air Gripper Series MHF2 Size: 8, 12, 16, 20 How to Order MHF 2 12 M9B D Number of auto switches Number of fingers Courtesy of Steven Engineering, Inc.-230 Ryan Way, South
Without adjuster type is not available for the 11-MXP6 series. 11-MXP How to Order MXPJ6 Clean series 11 Vacuum suction type 11 MXPJ6 10 22 MXPJ6 10 11-MXPJ6 Copper, fluorine and silicone-free + Low particle generation Stroke 5 10 5 mm 10 mm 22 Vacuum suction type With auto switch type is not available for the 11-MXPJ6 series.
A2 10 11 12 17 Model A1 6 10 10 11 MXF8 MXF12 MXF16 MXF20 A3 6 10 10 11 A4 21 23 28 34 A5 21 23 28 34 A6 10 11 12 17 Graph (2) Allowable Moment Coefficient: Note) Note) MXF8 MXF12 MXF16 MXF20 1.0 Allowable Moment Coefficient: Note) 16 mm for MXF8-10 only. 0.7 Stroke (mm) Table (4) Maximum Allowable Moment: Mmax (Nm) 0.5 0.4 Model 10 0.56 100 18.27 75 7.96 13.70 50 3.34 5.69 9.14 30 0.98
Fittings & Tubing Air Cylinders Rotary Actuators Relief port 2 x M5 x 0.8 2 x P through M5 x 0.8 R GC GB E GA MM D C J 2.8 2 x P through A 4 x T counterbore E 0.5 B H S Z (mm) 6 depth 4.8 5 S 10 15 20 25 30 5 Z 10 15 20 25 30 Bore size B C D E GA GB GC H J MM P R T A 13 22 3 23 16 15 13 10 3.2 7 M3 x 0.5 31 10 7 6 10 15 24 4 24 33.5 16 15.5 16 11 M4 x 0.7 3.2 9 6 depth 5 64 69 74 79 84 89
10-9 1.3 x 10-8 Kalrez 1.3 x 10-10 (FKM) Q1 R1 R2 R3 S1 T1 4079 SS592 SS630 SSE38 1232-70 Note 1) Values at ambient temperatures, excluding gas permeation.
X axis Y axis Z axis Z 5 W 5 mm 10 mm 20 mm 0.8 kg 20 Y 10 3.
Note 1) Data Note 2) Note 3) 10-3-13 13 The external dimensions and the related things about auto switches are the same as standard type, double acting, single rod. For Series CM2, refer to Best Pneumatics Vol. 6.
Note 1) Data Note 2) Note 3) 10-3-13 13 The external dimensions and the related things about auto switches are the same as standard type, double acting, single rod. For Series CM2, refer to Best Pneumatics Vol. 6.
Dimensions . 10 3-7. Air Gripper Single Unit .11 3-8. Center of gravity . 12 4. Product Specifications . 13 4-1. Attachment . 13 4-2. Protection cover . 14 4-3. Mounting to duAro flange . 15 4-4. Angle Adjustment of the Moving Direction of the Finger . 16 4-5. Piping . 17 4-6. Speed controller . 17 4-7. Finger open / close speed adjustment . 18 4-8.
Dimensions . 10 3-7. Air Gripper . 11 3-8. Center of gravity . 12 4. Product Specifications . 13 4-1. Attachment . 13 4-3. Mounting to NEXTAGE . 15 4-4. Piping . 16 4-5. Speed controller . 16 4-6. Finger open / close speed adjustment . 17 4-7. Connection of the auto switch and sensor harness . 18 5. Operating method or operation . 18 5-1. Precautions for Design . 18 5-2.
, 15, 20 25, 30, 35, 40 45, 50 12, 16 20, 25 Dimensions ...10 &11 Series CQS How to Order . 1 12 16 20 25 5, 10 Construction . 12 Solid state switch D-M9N, F9NV D-M9P, F9PV D-M9B, F9BV D-F9NW, F9NWV D-F9PW, F9PWV D-F9BW, F9BWV Dimensions ...13 to 16 Series CQSK How to Order . 1 12 16 5, 10, 15, 20, 25, 30 Construction . 17 20 25 5, 10, 15, 20, 25, 30 35, 40, 45, 50 Dimensions ...18 &19 Note
10 10 2 pcs. 10 15 20 2 pcs. 5 10 15 15 20 20 15 32, 40, 50 32, 40, 50 5 15 10 5 1 pc. 10 10 20 1 pc. 5 5 10 15 15 20 15 Other than the applicable auto switches listed in How to Order, the following auto switches can be mounted.