Nozzle Diameter: 13 (ø1.3mm), Vacuum Pressure: S (-90 kPa), SUP: 09 (One-touch Fitting ø5/16"), VAC: N02 (Screw-in NPT 1/4), EXH: 11 (One-touch Fitting ø3/8")
Nozzle Diameter: 13 (ø1.3mm), Vacuum Pressure: L (-48 kPa: ZH05 to 13D*A; -66 kPa: ZH15 to 20D*A), SUP: 09 (One-touch Fitting ø5/16"), VAC: N02 (Screw-in NPT 1/4), EXH: 11 (One-touch Fitting ø3/8")
Nozzle Diameter: 13 (ø1.3mm), Vacuum Pressure: S (-90 kPa), SUP: 09 (One-touch Fitting ø5/16"), VAC: N02 (Screw-in NPT 1/4), EXH: 11 (One-touch Fitting ø3/8"), Accessories: N (w/o Bracket, w/o Silencer)
Body Size: 4 (1/4 Basis), Port Size: N02 [Cylinder Side (NPT 1/4) Pilot Port (NPT 1/8)], Applicable Tube OD: 09 (Ø5/16")
-6 19.5 5/16 10 86 10 18 29.5 27 10.6 61.5 12 16 18.5 5/32 6 30 KM11-03-09-10 21.5 3/8 6 77.8 10 19.5 31.5 30.5 13.3 48 13 17 21 1/4 7 32 KM11-07-11-6 21.5 10 13.3 3/8 104 10 19.5 31.5 30.5 73.5 13 17 21 1/4 7 44 KM11-07-11-10 25 1/2 6 85 12.8 24 37.7 35.9 15.2 52.8 15 18.5 22 5/16 9.5 44 KM11-09-13-6 25 1/2 10 115 12.8 24 37.7 35.9 15.2 83 15 18.5 22 5/16 9.5 62 KM11-09-13-10 MORE DIMENSIONS
: 48.9 Atmospheric vent port 02 4 x 2.6 Depth 7 or less 20 30 25 8.5 11 R1/4 M5 x 0.8 Thread depth 5 4.2 N02 30 20 NPT1/4 17 Piping port 02: R1/4 N02: NPT1/4 2.5 If there is a possibility that the atmospheric vent port of the switch will be exposed to water or dust, insert a tube into the atmospheric vent port and route the other end of the tube to a safe place away from water or dust. *
D Side U Side C Switch specifications w How to Order Valves Nil J Without switch With switch Enter the symbols for the required specifications in the blanks below.
24 35 67 15.5 17.5 ZFC201-07 1/4" ZFC201-09 5/16" 1113 Series ZFC Element Replacement Element replacement procedure 4.
other than above For P kit For J kit For L kit For S kit Note) The !
other than above For P kit For J kit For L kit For S kit Note) The !
/N.O. 1 2 3 4 5 A B C Switch Made to Order Nil J Without switch With switch Main valve fluororubber (Refer to page 411.)
VVQ1000-J-1-A VVQ1000-J-1-B Ejector valve model Nozzle diameter (mm) 0.7 1.0 Max. suction flow rate N (NL/min) 11 20 Note 1) SUP and EXH ports on the ejector unit manifold base are arranged on D-side alone. The end plate on the U-side is the same as that used in the L kit. Note 2) Individual piping is provided for the supply and exhaust ports of the ejector unit.
L4 Note) Weight (g) 5 5.5 6.5 8.5 9.5 19 22 35 38 52 86 95 Model Applicable tubing O.D. d AS1002F-01 AS1002F-03 AS1002F-07 AS2002F-03 AS2002F-07 AS2052F-07 AS2052F-09 AS3002F-07 AS3002F-09 AS3002F-11 AS4002F-11 AS4002F-13 MIN.
Steel) 4w 1P300.1P3100 DIMENSIONS MODEL 1P300 (Lever Type) l t I I I J J O
J When J is selected for e, install the release valve or vacuum breaker in the middle of the vacuum piping.
L O L G H F K J E D I A B C 2-4.5 A B C D E F G H I J K L Model 4 ZFC100-04 6 ZFC100-06 53.2 9.1 30 14.1 10 18 11.6 19.5 23 20 29 5/32" ZFC101-03 1/4" ZFC101-07 6 ZFC200-06 8 ZFC200-08 67 15.5 34 17.5 14 22 15.6 23.1 27 24 35 1/4" ZFC201-07 5/16" ZFC201-09 Element Replacement Element replacement procedure 1) Stop operation and reduce the filter's internal pressure to atmosphere. 2) Turn cover
L O L G H F K J E D I A B C 2-4.5 A B C D E F G H I J K L Model 4 ZFC100-04 6 ZFC100-06 53.2 9.1 30 14.1 10 18 11.6 19.5 23 20 29 5/32" ZFC101-03 1/4" ZFC101-07 6 ZFC200-06 8 ZFC200-08 67 15.5 34 17.5 14 22 15.6 23.1 27 24 35 1/4" ZFC201-07 5/16" ZFC201-09 Element Replacement Element replacement procedure 1) Stop operation and reduce the filter's internal pressure to atmosphere. 2) Turn cover
08 67 15.5 34 17.5 14 22 15.6 23.1 27 24 35 1/4" ZFC201-07 AMJ 5/16" ZFC201-09 Misc.
Internal Wiring of Manifold 09 9 stations Serial type 45S3 16 16 stations This also includes the number of blanking plate assemblies. When special wiring is required on manifold with 2 to 8 stations, please use the manifold specification sheet. G71-OD16 output no.