Models Standard strokes (mm) 32 40 50 63 MGP 25, 50, 75, 100, 125, 150, 175 200, 250, 300, 350, 400 M L Intermediate strokes (in 5mm increments) are produced by installing spacers of 5, 10, 15 and 20mm widths. When a special intermediate stroke body is needed, contact SMC.
100 200 300 400 500 100 200 300 400 500 Piston speed (mm/s) Horizontal mounting Piston speed (mm/s) Vertical mounting Selection O.K. NO NO YES Is it possible for cable of stroke reading cylinder to be wired separately from the power line? Is there any influence of noise? YES NO YES NO Can the system be operated below 14.5 mT? Do not use it since it will result in a miscount.
To use the system in a magnetic field that exceeds this value, use a magnetic material to shield the sensor unit. 63 50 50 40 40 YES 100 200 300 400 500 100 200 300 400 500 NO Does the mounted load exceed the load given in the diagram? Piston speed (mm/s) Horizontal mounting Piston speed (mm/s) Vertical mounting Selection O.K.
Z73 Y59A Y7P Y59B Y7NW Y7PW Y7BW 3-wire (NPN) 2-wire Y69A Y7PV Y69B Y7NWV Y7PWV Y7BWV 100 V or less IC circuit 5 V, 12 V 3-wire (PNP) IC circuit 2-wire 12 V Relay, PLC 24 V Grommet 3-wire (NPN) 3-wire (PNP) 5 V, 12 V Diagnostic indication (2-color indication) 2-wire 12 V Lead wire length symbols: 0.5 m Nil (Example) Y59A 3 m L (Example) Y59AL 5 m Z (Example) Y59AZ Since there are
switch model Electrical entry Indicator light Wiring (Output) Pre-wire connector Special function Applicable load In-line 0.5 (Nil) 3 (L) 5 (Z) DC AC Type Perpendicular 3-wire (NPN) 3-wire (PNP) Y59A Y69A IC circuit 5 V 12 V Y7P Y7PV Solid state switch 12 V Y59B Y69B 2-wire Relay, PLC Grommet Yes 24 V 3-wire (NPN) 3-wire (PNP) Y7NW Y7NWV IC circuit 5 V 12 V Diagnosis (2-color indication) Y7PW
Output) Electrical entry Applicable load Double Acting D 3 wire (NPN) Opening/closing stroke (mm) Y59A Y69A IC 5V, 12V Symbol 10 16 20 25 32 40 30 60 80 circuit 3 wire (PNP) Y7PV Y7P 20 40 60 40 80 100 50 100 120 70 120 160 100 160 200 Solid state switch 1 2 Y69B Y59B 2 wire 12V Grommet Relay, PLC 3 wire (NPN) Y7NWV With 24V Y7NW IC Diagnosis 5V, 12V circuit indicator 3 wire (PNP) Y7PWV Y7PW
D-Y7NW(V)/D-Y7PW(V)/D-Y7BW(V) Direct Mounting Style ... 2-color Indication Type with Diagnostic Output. D-F79F Rail Mounting Style. Water Resistant 2-color Indication Type. D-F7BA(V)L Water Resistant Rail Mounting Style . D-F9BAL Water Resistant Direct Mounting Style . D-Y7BAL Water Resistant Direct Mounting Style . Solid State Switch with Timer . D-F7NTL Rail Mounting Style .
1/8 Specifications Suction Flow Rate of Vacuum Suction Type (Reference values) Bore size (mm) 10/15 20/25/32 6 Item 1.05 MPa 0.7 MPa Proof pressure Maximum operating pressure Minimum operating pressure Ambient and fluid temperature Piston speed Stroke adjustable range Size Suction flow rate L/min (ANR) 6 10 15 20/25 32 2 5 10 15 20 0.1 MPa 0.05 MPa 0.15 MPa 10 to 60C (No freezing) 30 to 400
and Z1 axis mm Inertia moment around the Z1 axis of A part of attachment kgm2 IZ1 MHL Distance between Z and Z2 axis mm Inertia moment around the Z2 axis of B part of attachment kgm2 IZ2 MHR Allowable Range of Inertia Moment of Attachment MHY2-10D MHW2-20D MHW2-50D MHK 1.2 6 600 Moment of inertia (x 10-4 kgm2) Moment of inertia (x 10-4 kgm2) Moment of inertia (x 10-4 kgm2) 5 500 MHS 1.0 4 400
.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 1.2 6 600 Moment of inertia (x 10-4 kgm2) Moment of inertia (x 10-4 kgm2) Moment of inertia (x 10-4 kgm2) 5 500 MHS 1.0 4 400 0.8 MHC 3 300 0.6 MHT 2 200 0.4 1 100 0.2 MHY 0 0 0 0.1 0.2 0.4 0.5 0.3 0.1 0.2 0.3 0.2 0.4 0.6 0.8 1.0 1.2 MHW Operating time
Distance between Z and Z1 axis Inertia moment around the Z1 axis of A part of attachment IZ1 r1 kgm2 mm Distance between Z and Z2 axis Inertia moment around the Z2 axis of B part of attachment IZ2 r2 Allowable range of inertia moment of attachment MHY2-10D MHW2-20D MHW2-50D 1.2 6 600 5 500 Moment of inertia (X10-4 kgm2) Moment of inertia (X10-4 kgm2) Moment of inertia (X10-4 kgm2) 1.0 4 400
Nil S n Standard stroke Standard stroke (mm) 100, 150, 200, 250, 300 350, 400, 450, 500, 600, 700 Bore size (mm) Type of auto switch 15, 32 Nil Select auto switches from the table below.
Straight type Stroke Air supply unit Note 1) 200 250 300 350 400 450 500 600 1000 200mm 250mm 300mm 350mm 400mm 450mm 500mm 600mm 1000mm Qty. None 1 set 2 sets Description Symbol Nil AS AW A unit (Air system 1) Note 1) Air supply unit, 1 set breakdown: Supply block (slide table side) 1pc. Supply ring (plate side) 2pcs. The maximum produceable stroke is 5000mm.
Type: Rodless Cylinder, Cylinder Inner Diameter(Ø): 32, Stroke(mm): 400, Max.
Type: Rodless Cylinder, Cylinder Inner Diameter(Ø): 25, Stroke(mm): 400, Max.
Type: Rodless Cylinder, Cylinder Inner Diameter(Ø): 32, Stroke(mm): 400, Max.
Type: Rodless Cylinder, Cylinder Inner Diameter(Ø): 25, Stroke(mm): 400, Max.
Magnet: Built-in, Mounting: Center Trunnion, Tube Material: Aluminum Tube, Model Selection: Standard, Bore Size: 63mm, Thread: Rc, Stroke: 400mm, Suffix: w/o Gaiter w/Cushion Both Sides, Auto Switch: Y7PW--Solid State, 2-color Indication, 3 Wire PNP, Horizontal, Lead Wire or Prewired Connector: -, Number: -
Bore Size: 32mm, Port Thread: Rc (25-100 Bore, M Thread 16-20 Bore), Piping: Standard, Stroke: 400mm, Stroke Adjusting Unit: w/o Adjustment Unit, Auto Switch: Y7PW--Solid State, 2-color Indication, 3 Wire PNP, Horizontal, Lead Wire or Prewired Connector: -, Number: -, Made to Order: -