Indicator light Wiring (Output) Special function Type Electrical entry Electrical entry direction Applicable load 0.5 (Nil) 3 (L) AC DC Perpendicular In-line A90V A90 w/o 100V or less IC circuit 5V, 12V Relay PLC 24V 2 wire Reed switch Solid state switch A93V A93 100V 12V Grommet With 3 wire (Equivalent to NPN) A96V A96 IC circuit 5V F9NV F9N 3 wire (NPN) F9PV F9P 3 wire (PNP) F9BV F9B
Lead wire (m) 0.5 () Load voltage Auto switch model Indicator Wiring (Output) Specification details Special function Style Electrical entry Load Electrical entry 3 (L) AC DC Perpendicular In-line No A90V A90 100V or less IC circuit 5V, 12V Relay, PLC Reed switch Solid state switch 24V 2 wire A93V A93 100V 12V P.5.3-19 Grommet Yes A96V A96 IC circuit 5V 3 wire(Equiv.
Series CG1 precision air cylinder has 8 bore sizes and can meet any application need. The tube is impact extruded aluminum to produce an extraordinarily smooth finish, allow low break-away pressure and smooth stroke action. Eight mounting options are available. Auto switch capable. CG1, double acting, single rod cylinder with made-to-order options, Bores sizes *: 20, 25, 32, 40, 50 63 *,
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYLINDER, ACTUATOR, CG/CG3 ROUND BODY CYLINDER, ME, 40MM CG DBL-ACT AUTO-SW, 5.29109 lb
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYLINDER, ACTUATOR, CG/CG3 ROUND BODY CYLINDER, ME, 40MM CG DBL-ACT AUTO-SW, 5.29109 lb
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYLINDER, ACTUATOR, CG/CG3 ROUND BODY CYLINDER, ME, 40MM CG DBL-ACT AUTO-SW, 5.29109 lb
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYLINDER, ACTUATOR, CG/CG3 ROUND BODY CYLINDER, ME, 40MM CG DBL-ACT AUTO-SW, 5.29109 lb
Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 75, Cylinder Operation Method: [Single Action Retraction] Single Acting, Spring Extend, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Cushion: Rubber cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet, Auto Switches: Without auto
Magnet: D (Built-in Magnet), Mounting: L (Axial Foot), Type: N (Rubber Bumper), Bore: 40mm, Port Thread Type: Rc (or M5, Depending on Style, Bore Size, and Thread Combination), Stroke: 400mm, Thread: Male Rod End, Suffix for Cylinder: w/o Rod Boot
Magnet: Built-in Magnet, Mounting: Axial Foot, Type: Rubber Bumper, Bore: 40mm, Port Thread Type: Rc (or M5, Depending on Style, Bore Size, and Thread Combination), Stroke: 200mm, Thread: Female Rod End, Suffix for Cylinder: w/o Rod Boot, Pivot Bracket: -, Rod End Bracket: -, Auto Switch: -, Lead Wire or Prewire Connection: -, Number: -, X Option: -
Magnet: Built-in Magnet, Mounting: Axial Foot, Type: Rubber Bumper, Bore: 40mm, Port Thread Type: Rc (or M5, Depending on Style, Bore Size, and Thread Combination), Stroke: 50mm, Thread: Female Rod End, Suffix for Cylinder: w/o Rod Boot, Pivot Bracket: -, Rod End Bracket: -, Auto Switch: -, Lead Wire or Prewire Connection: -, Number: -, X Option: -
Magnet: Built-in Magnet, Mounting: Axial Foot, Type: Rubber Bumper, Bore: 40mm, Port Thread Type: Rc (or M5, Depending on Style, Bore Size, and Thread Combination), Stroke: 800mm, Thread: Female Rod End, Suffix for Cylinder: w/o Rod Boot, Pivot Bracket: -, Rod End Bracket: -, Auto Switch: -, Lead Wire or Prewire Connection: -, Number: -, X Option: -
Magnet: Built-in Magnet, Mounting: Axial Foot, Type: Rubber Bumper, Bore: 40mm, Port Thread Type: Rc (or M5, Depending on Style, Bore Size, and Thread Combination), Stroke: 75mm, Thread: Female Rod End, Suffix for Cylinder: w/o Rod Boot, Pivot Bracket: -, Rod End Bracket: -, Auto Switch: -, Lead Wire or Prewire Connection: -, Number: -, X Option: -
Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 25, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Cushion: Rubber cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet, Port thread type: Rc, Auto Switches: Without auto switch
Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 50, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Cushion: Rubber cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet, Port thread type: Rc, Auto Switches: Without auto switch
Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 50, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Cushion: Rubber cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet, Port thread type: Rc, Auto Switches: Without auto switch
Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 60, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Cushion: Rubber cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet, Port thread type: Rc, Auto Switches: Without auto switch
Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 75, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Cushion: Rubber cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet, Port thread type: Rc, Auto Switches: Without auto switch
Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 100, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Cushion: Rubber cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet, Port thread type: Rc, Auto Switches: Without auto switch
Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 125, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Cushion: Rubber cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet, Port thread type: Rc, Auto Switches: Without auto switch