Note D-F7/J79 D-F7V D-J79C D-F7W/J79W D-F7WV D-F7BAL/F7BAVL D-F79F D-F7NTL Switch mounting screw RS H A 20, 25 BQ-1 (M3 x 0.5 x 8l) Square nut D-A7/A8 D-A73C/A80C D-A7H/A80H D-A79W RZQ Switch mounting screw 32, 40 50, 63 Magnetic body (Steel plate, etc.)
8 to @0, $1 to $4 (1 set) 8-5-45 46 Series MXQ Proper Auto Switch Mounting Position (Detection at stroke end) Reed Switch: D-A90, D-A93, D-A96, D-A90V, D-A93V, D-A96V Stroke B Stroke E Model A 10 20 30 40 50 75 100 125 150 10 20 30 125 40 50 150 75 100 11.5 (9) 29 (26.5) 19.5 (17) 24.5 (22) 29.5 (27) 44.5 (42) 11.5 (9) 14 (11.5) 19.5 (17) 18.5 (16) 31.5 (29) 30.5 (28) 3.5 (1) 10 (7.5) 12.5
entry is not available for 50 and 63. ( ) D-Y69A, D-Y69B, D-Y7PV D-Y7NWV, D-Y7PWV, D-Y7BWV 8-12-23 24 Series MY1W Mounting of Auto Switch & Installation of Lead Wire Cover (50, 63) Caution Be sure to install a lead wire cover on the auto switches for size 50 and 63 cylinders.
model D-F5 D-J5 D-F5W D-J59W D-F5BAL D-F59F D-F5NTL D-A5 D-A6 D-A3 D-A44 D-G39 D-K39 D-F5W D-J59W D-F5BAL D-F5 D-J5 D-F59F D-A59W D-F5NTL Bore size (mm) Bore size (mm) A B A B A B A B Hs Hs Ht Hs Hs Ht 125 125 2 75.5 69.5 74.5 70 116 126 4.5 4.5 9.5 9.5 0 0 2 140 140 2 81 76.5 80 76.5 124 134 4.5 4.5 9.5 9.5 0 0 2 160 160 2 89 87.5 88 87.5 134.5 144.5 4.5 4.5 9.5 9.5 0 0 2 180 180 7.5 97.0
Auto Switch Proper Mounting Position (mm) Auto switch model D-M9 D-M9W D-A9 Bore size A A B B 20 25 32 40 10.5 9.5 6.5 5.5 10.5 9.5 6.5 5.5 11.5 10.5 7.5 6.5 17.5 15.5 13.5 11.5 Note) The above-mentioned value is a guide for auto switch mounting positions for stroke end detection.
P Q S 5 to 50 40 33 Data 9 depth 7 32 50 43 13 16 45 7.5 M8 x 1.25 60 4.5 14 7 34 5.5 1/8 10.5 58.5 31.5 14 75, 100 50 43 5 to 50 46.5 39.5 9 depth 7 40 56.5 49.5 13 16 52 8 M8 x 1.25 69 5 14 7 40 5.5 1/8 11 66 35 14 75, 100 56.5 49.5 10 to 50 48.5 40.5 11 depth 8 50 58.5 50.5 15 20 64 10.5 M10 x 1.5 86 7 17 8 50 6.6 1/4 10.5 80 41 19 75, 100 58.5 50.5 10-4-7 8 Series CQ2Y Dimensions/63 to
D40 20.5 23.5 28.5 M14 x 1.5 50 26 28.5 33.5 M18 x 1.5 -X (mm) Without auto switch With auto switch A B A B 20U Z Bore size (mm) Stroke range (mm) C D E F H I J K L M N O P Q S 5 to 50 40 33 Data 9 depth 7 32 50 43 13 16 45 7.5 M8 x 1.25 60 4.5 14 7 34 5.5 1/8 10.5 58.5 31.5 14 75, 100 50 43 5 to 50 46.5 39.5 9 depth 7 40 56.5 49.5 13 16 52 8 M8 x 1.25 69 5 14 7 40 5.5 1/8 11 66 35 14 75
, 15, 20 25, 30, 35, 40 45, 50 12, 16 20, 25 Dimensions ...10 &11 Series CQS How to Order . 1 12 16 20 25 5, 10 Construction . 12 Solid state switch D-M9N, F9NV D-M9P, F9PV D-M9B, F9BV D-F9NW, F9NWV D-F9PW, F9PWV D-F9BW, F9BWV Dimensions ...13 to 16 Series CQSK How to Order . 1 12 16 5, 10, 15, 20, 25, 30 Construction . 17 20 25 5, 10, 15, 20, 25, 30 35, 40, 45, 50 Dimensions ...18 &19 Note
The switch rail accessory type is mentioned on page 14, and can be ordered together with auto switches. (2) Refer to the separate disassembly instructions for switch magnet installation procedures. 17 Series CY3B Magnetically Coupled Rodless Cylinder Direct Mount Type Reed Switch Internal Circuit Brown DC (+) Brown D-A96 D-Z76 D-A93 D-Z73 D-A90 D-Z80 LED LED Contact protection box CD-P11
MY1CW16/20 MY1MW16/20 B A Reed Switch Solid State Switch D-A90(V), D-A93(V), D-A96(V) (mm) D-M9N(V), D-M9P(V), D-M9B(V) D-F9NW(V), D-F9PW(V), D-F9BW(V) 16 20 Mounting position Mounting position 16 20 A A B B Operating range Note) Operating range Note) Solid State Switch Reed Switch 24 Series MY1W Mounting of Auto Switch & Installation of Lead Wire Cover (50, 63) Caution Be sure to install
Fittings & Tubing Air Cylinders Rotary Actuators How to Order Clean series 10 11 Relief type Vacuum suction type Built-in magnet D With auto switch Bore size (mm) 10 C D U 16 30 D M9B 21 C D U 16 30 D M9B Cylinder stroke (mm) Copper, fluorine and silicone-free + low particle generation Number of auto switches Nil S n 2 pcs. 1 pc. n pcs. 21 22 Relief type Vacuum suction type Auto switch D-A93
(mm) D-M9V D-M9WV D-M9A D-M9AV D-A9 D-A9V D-M9 D-M9V D-M9W D-M9WV D-M9A D-M9AV D-A90V D-A96V D-A93V Bore size (mm) D-A90 D-A96 D-A93 D-M9 D-M9W Bore size (mm) Mounting pattern q, w Mounting pattern e 32 32 20 22 35 20 10 15 25 12 5 10 Mounting of Auto Switch As shown below, there are 3 ways to mount the auto switch according to 3 types of electrical entries.
(n 2) 2 D-C7 D-C80 D-H7C D-C73C D-C80C D-G5/K59 D-G5W/K59W D-G59F/G5BA/G5NT D-B5/B64 50 + 45 (n 2) (n = 2, 3, 4, 5) 10 15 50 D(n = 2, 4, 6) Note 3) 15 + 50 (n 2) 2 65 + 50 (n 2) (n = 2, 3, 4, 5) 10 15 65 15 + 50 (n 2) 2 75 + 55 (n 2) (n = 2, 3, 4, 5) 10 15 75 (n = 2, 4, 6) Note 3) (n = 2, 4, 6) Note 3) 20 + 50 (n 2) 2 75 + 55 (n 2) (n = 2, 3, 4, 5) D-B59W 15 20 Note 3) When n is
Internal voltage drop Indicator light (lights when ON) Applications AC DC 24V or less AC DC 48V or less AC DC100V or less 24VDC 100VAC 50mA 40mA 20mA 5 to 40mA 5 to 20mA Relay, PLC, IC circuit D-A90 D-A90V None 0 Relay, PLC D-A93 D-A93V 2.6V or less D-A96 D-A96V 4 to 8VDC 20mA 0.8V or less IC circuit Lead wires D-A90, A93 : Oil resistant heavy duty vinyl cord 2.7 0.18mm x 2 wire (Brown
Load voltage Internal voltage drop (illuminated load current load when ON) range AC DC 24V or less 50mA Relay D-A90 AC DC 48V or less 40mA Not provided PLC D-A90V IC circuit AC DC 100V or less 20mA D-A93 2.4V or less (up to 20mA) 3V or less DC24V 5 to 40mA D-A93 Provided Relay (up to 40mA) D-A93V PLC D-A93V 2.7V or less AC100V 5 to 20mA 2.7V or less D-A96 D-A96V DC4 to 8V 20mA 0.8V or less
63 80 100 MGTL D-Y5 type D-Z7 type Note 1) Note 1) D-Z8 type D-A9 type D-F9 type D-Y6 type D-Y7 type Note 1) Vertical outlet types cannot be mounted.
Wiring Electrical entry Auto switch type Electrical entry from inside 3-wire D-F9P B Solid state switch D-F9 In-line 2-wire D-F9B 3-wire D-F9NW,D-F9PW In-line 2 color indication solid state switch D-F9 W 2-wire D-F9BW 3-wire D-F9NWV,D-F9PWV Perpendicular B 2-wire D-F9BWV Install auto switch as shown in figure below.
Solid state auto switch: D-M9B, D-M9N B E Model Auto switch operating range Stroke Stroke A 40 50 150 100 75 100 10 20 30 125 75 20 30 125 150 10 40 50 13-/22-MXS6 0.4 0.4 0.4 11.6 17.5 9.6 9.6 9.6 21.6 27.6 1.5 10 13-/22-MXS8 4.9 0.1 0.9 8.9 16.9 41.9 14.9 9.9 10.9 18.9 26.9 51.9 1.5 11.6 13-/22-MXS12 74.4 32.4 22.4 12.4 14.4 24.4 22.4 12.4 2.4 4.4 14.4 35.4 64.4 2.5 45.4 15.6 13-/22
Auto Switch Proper Mounting Position (Detection at Stroke End) D-A93 12 16 to 25 A B W A B W D-M9B/M9N 12 16 to 25 A B W A B W B D-A93 B D-M9B/M9N/M9P Bore size (mm) A 11.5 W 4 A 15.5 W 5.5 12 16 20 25 0.5 4.5 12 0 4.5 16 4 6 16 3.5 1 20 7.5 2.5 17 5.5 -1 21 9.5 0.5 Specific Product Precautions Be sure to read this before handling. Mounting Caution 1.
200 275 60 67 MXW25-250 1 640 7 138 109 210 360 225 300 65 80 MXW25-275 1 690 7 163 134 232 395 245 320 60 60 52 MXW25-300 2 740 8 188 159 153 MXW Series Long Stroke Slide Table Auto Switch / Suitable Mounting Position at Stroke End Detection Reed switch: D-A90 (V), D-A93 (V), D-A96 (V) Switch operation range Stroke (mm) Model 25 50 75 100 125 150 175 200 225 250 275 300 A 52.5 31.5 27.5