Note 2) When symbols C or D are specified, an auto drain with a part number shown on page 18 is mounted.
(different sides, same side) D-Z73, Z76, Z80 Reed switch 15 25 1pc. D-Y59A(B), Y69A(B), 2pcs. (different sides, same side) 15 25 Y7P(V) 1pc. D-Y7NW(V), Y7PW(V), 2pcs. (different sides, same side) Solid state switch 20 25 Y7BW(V) 1pc. 2pcs. (different sides, same side) 20 30 D-Y7BAL 1pc. Center trunnion is not included.
Magnet: Built-in, Mounting: Rear Flange, Style: Aluminum Tube, Bore Size: 100mm, Thread: Rc, Stroke: 250mm, Option: w/o Rod Boot, Cushion: Both Sides (Air-hydro has No Cushion), Lock Operation: Spring/Air Pressure Lock, Auto Switch: A53--Reed, DC Volt >5<24, LED, Lead Wire or Prewied Connector: -, Number: -
Magnet: Built-in, Mounting: Rear Flange, Style: Aluminum Tube, Bore Size: 100mm, Thread: Rc, Stroke: 300mm, Option: w/o Rod Boot, Cushion: Both Sides (Air-hydro has No Cushion), Lock Operation: Spring/Air Pressure Lock, Auto Switch: A54--Reed, DC Volt >5<24, AC Volt <200, LED, Lead Wire or Prewied Connector: 3m, Number: -
Magnet: Built-in, Mounting: Rear Flange, Style: Aluminum Tube, Bore Size: 100mm, Thread: Rc, Stroke: 500mm, Option: w/o Rod Boot, Cushion: Both Sides (Air-hydro has No Cushion), Lock Operation: Spring/Air Pressure Lock, Auto Switch: A53--Reed, DC Volt >5<24, LED, Lead Wire or Prewied Connector: 3m, Number: -
Magnet: Built-in, Mounting: Rear Flange, Style: Aluminum Tube, Bore Size: 100mm, Thread: Rc, Stroke: 500mm, Option: w/o Rod Boot, Cushion: Both Sides (Air-hydro has No Cushion), Lock Operation: Spring/Air Pressure Lock, Auto Switch: J59W--Solid State, 2-color Indication, 2 Wire, Lead Wire or Prewied Connector: 3m, Number: -
Magnet: Built-in, Mounting: Rear Flange, Style: Aluminum Tube, Bore Size: 100mm, Thread: Rc, Stroke: 600mm, Option: w/o Rod Boot, Cushion: Both Sides (Air-hydro has No Cushion), Lock Operation: Spring/Air Pressure Lock, Auto Switch: A53--Reed, DC Volt >5<24, LED, Lead Wire or Prewied Connector: 3m, Number: -
Cylinder (Tube) Inner Diameter(φ): 100, Stroke(mm): 450, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Cushion: With cushions on both sides, Operating Pressure(MPa): 0.08 to 1.0, Specification
Cylinder (Tube) Inner Diameter(φ): 100, Stroke(mm): 450, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Cushion: With cushions on both sides, Operating Pressure(MPa): 0.08 to 1.0, Specification
80 100 No. of auto switches mounted Type Auto switch model Auto switch model 32 40 50 63 80 100 2 (Different sides, Same side) D-Z7/Z80 Reed switch 15 25 10 10 11 11 12 D-Z7/Z80 10 1 D-Y59/Y69 2 (Different sides, Same side) D-Y59/Y69/ D-Y7P/Y7PV 6.5 6.5 6 7 7 8 15 25 D-Y7P/Y7PV 1 D-Y7W/Y7WV 6.5 6.5 6 7 7 8 2 (Different sides, Same side) Solid state switch D-Y7W/Y7WV 20 25 1 5 5 5 5 6 D-Y7BAL
10 1 D-Y59/Y69 2 (Different sides, Same side) D-Y59/Y69/ D-Y7P/Y7PV 6.5 6.5 6 7 7 8 15 25 D-Y7P/Y7PV 1 D-Y7W/Y7WV 6.5 6.5 6 7 7 8 2 (Different sides, Same side) Solid state switch D-Y7W/Y7WV 20 25 1 6 D-Y7BAL 5 5 5 5 5 2 (Different sides, Same side) 20 30 1 D-Y7BAL Center trunnion is not included.
(different sides or same side) 15 25 1 pc. 10 Auto Switches / Proper Mounting Position and Height for Stroke End Detection Reed switch Solid state switch A B Hs A B Hs Ht Ht Auto switch mounting position Auto switch mounting height D-A5 D-A6 D-A59W D-F5, D-J5 D-F5W D-J59W D-F5BAL D-F5 D-J5 D-A5, D-A6 D-A59W D-F5NTL D-F5W, D-J59W D-F5BAL, D-F5NTL Bore size (mm) Bore size (mm) Hs Ht Ht Hs B
Example Data Theoretical Output Minimum Stroke for Auto Switch Mounting OUT IN (N) (mm) Rod size (mm) Operating direction Piston area (mm2) Operating pressure (MPa) Bore size (mm) D-Z7 D-Z80 D-Y59 D-Y7P D-Y7W 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 No. of auto switches mounted D-Y69 D-Y7PV D-Y7WV D-Y7BAL D-P5DWL 314 283 251 220 188 157 126 94 63 314 OUT 20 10 236 212 189 165 142 118 94 71 47
Example Data Theoretical Output Minimum Stroke for Auto Switch Mounting OUT IN (N) (mm) Rod size (mm) Operating direction Piston area (mm2) Operating pressure (MPa) Bore size (mm) D-Z7 D-Z80 D-Y59 D-Y7P D-Y7W 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 No. of auto switches mounted D-Y69 D-Y7PV D-Y7WV D-Y7BAL D-P5DWL 283 314 220 251 157 188 94 126 314 63 OUT 20 10 236 212 189 165 142 118 94 71 47
(Not mountable after the time of shipment) RHC MK(2) Auto Switch Mounting Height RS Q G D-B5/B64 D-B59W D-G5 D-K59 D-G5NTL D-G5W D-K59W D-G59F D-F5 D-J5 D-F5W D-J59W D-F59F D-F5NTL Auto switch model D-Z7/Z80 D-Y59 D-Y7P D-Y7W D-Y69 D-Y7PV D-Y7lWV D-A44 D-A44C D-A3 D-G39 D-K39 D-A3C D-G39C D-K39C D-A5 D-A6 D-A59W RS H A RZQ Bore size (mm) Hs Ht Hs Hs Hs Ht Hs Hs Ht Hs Ht Hs Hw Hs Hw MI W S
(Not mountable after the time of shipment) RHC MK(2) Auto Switch Mounting Height RS Q G D-B5/B64 D-B59W D-G5 D-K59 D-G5NTL D-G5W D-K59W D-G59F D-F5 D-J5 D-F5W D-J59W D-F59F D-F5NTL Auto switch model D-Z7/Z80 D-Y59 D-Y7P D-Y7W D-Y69 D-Y7PV D-Y7lWV D-A44 D-A44C D-A3 D-G39 D-K39 D-A3C D-G39C D-K39C D-A5 D-A6 D-A59W RS H A RZQ Bore size (mm) Hs Ht Hs Ht Hs Hs Hs Hs Ht Hs Ht Hs Hw Hs Hw MI W S
CNS D-H7C D-B5, D-B6, D-B59W CLS HS HS Auto switch Auto switch 12 8.5 CLQ 24.5 16 MLGP A B A B 33 38.2 RLQ MLU Proper Auto Switch Mounting Position Auto Switch Mounting Height ML1C Auto switch model D-C7/C80 D-H7 D-H7W D-H7NF D-H7BAL D-H7 D-H7C D-H7W D-H7BAL D-H7NF D-C7/C80 D-C73C D-C80C D-B5/B64 DD-B5/B64 D-B59W D-G5NTL D-H7C D-C73C D-C80C D-G5NTL D-B59W -X Bore size (mm) A B A B A B A B
Auto Switch Mounting Dimensions D-Z7, D-Z8 (Reed switch) D-Y5, D-Y6, D-Y7 (Solid state switch) Dimension A Bore size Switch types 6 10 15 20 25 32 A D-Y59A, D-Y7P, D-Y59B D-Y69A, D-Y7PV, D-Y69B D-Y7NWV, D-Y7PWV, D-Y7BWV D-Y7NW, D-Y7PW, D-Y7BW D-Y7BAL D-Z7, D-Z8 0.2 0.7 6.0 0.7 6.5 1.2 Auto Switch Mounting Caution When mounting and securing auto switches, they should be inserted into the cylinder's
Note EVS Manifold block assembly VZ1000-1A-1 q D side For D side, with D-sub connector and P/R port with One-touch fitting for 6 SUP/EXH block assembly SUP/EXH block assembly VZ1000-2A-1D w VFN For U side, with D-sub connector and P/R port with One-touch fitting for 6 DIN rail VZ1000-2A-1U e End block assembly End block assembly For D side For U side Without D-sub connector For indicated
M Special specifications Mixed M D D side In the case of mixed specifications (M), indicate separately on the manifold specification sheet.