SMC Corporation of America
Elite Part Number Search
Search Results "CDLA2L40TN-125N-D-A93"

Magnet: Built-in, Mounting: Single Clevis, Style: Aluminum Tube, Bore Size: 80mm, Thread: NPT, Stroke: 125mm, Option: N [w/o Rod Boot, w/o Cushion (Not Valid for Air-hydro), Lock Operation: Spring/Air Pressure Lock, Auto Switch: -, Lead Wire or Prewied Connector: -, Number: -

Magnet: Built-in Magnet, Mounting: Axial Foot, Tube Material: Aluminum Tube, Bore Size: 100mm, Thread: Rc, Stroke: 125mm, Bellows/Cushion: w/o Cushion, Auto Switch: -, Lead Wire or Prewired Connector: -, Number: -

Magnet: None, Mounting: Axial Foot, Tube Material: Aluminum Tube, Bore Size: 100mm, Thread: Rc, Stroke: 125mm, Bellows/Cushion: w/o Cushion, Auto Switch: -, Lead Wire or Prewired Connector: -, Number: -

Cylinder (Tube) Inner Diameter(φ): 63, Stroke(mm): 125, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Cushion: None, Operating Pressure(MPa): -, Specification: -, Port thread type:

Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 125, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: [Included] Presence, Valves: No,

Cylinder (Tube) Inner Diameter(φ): 63, Stroke(mm): 125, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: [Included] Presence, Valves: No,

(mm) Auto Switch Mounting Height Auto switch model Band mounting D-H7l/H7lW D-H7NF D-H7BA D-C7l/C80 D-M9lV D-M9lWV D-M9lAV D-A9lV D-M9l D-M9lW D-M9lA D-A9l D-H7C D-C73C D-C80C Hs Hs Hs Hs Hs 6 15 16 15 18 17.5 10 17 18 17 20 19.5 16 20.5 21 20.5 23.5 23 Bore size (mm) Auto switch model Rail mounting D-M9l D-M9lV D-M9lW D-M9lWV D-M9lA D-M9lAV D-A9l D-A9lV D-F7l/J79 D-F7lW/J79W D-F7BA/F79F

(M)(L)(Z) Solid state auto switch M9P(M)(L)(Z) D-M9P(M)(L)(Z) M9B(M)(L)(Z) D-M9B(M)(L)(Z) A90(L) D-A90(L) Reed auto switch (Not applicable to flange size 16) A93(M)(L)(Z) D-A93(M)(L)(Z) M9// Without auto switch (with magnet) * Standard lead wire length is 0.5 m.

D-M9 D-F9W 22 (24.5) ( ): Denotes the values of D-A93.

D-C73/D-C76/D-C80 Band Mounting Style. D-B53/D-B54/D-B64 Band Mounting Style . D-C73C/D-C80C Band Mounting Style. D-A72/D-A73/D-A80 Band Mounting Style . D-A7xH/D-A80H Rail Mounting Style. D-A73C/D-A80C Rail Mounting Style . D-A90(V)/D-A93(V)/D-A96(V) Direct Mounting Style . D-Z73/D-Z76/D-Z80 Direct Mounting Style. D-E73A/D-E76A/D-E80A Direct Mounting Style. 2-color Indication Type .

, M9P, M9B, M9NV, M9PV, M9BV D-M9NW, M9PW, M9BW, M9NWV, M9PWV, M9BWV D-M9NA, M9PA, M9BA, M9NAV, M9PAV, M9BAV Reed D-A90, A93, A96, A90V, A93V, A96V Standard 1.

(M)(L)(Z) D-M9P(M)(L)(Z) D-M9B(M)(L)(Z) D-A90(L) D-A93(M)(L)(Z) M9N(M)(L)(Z) M9P(M)(L)(Z) M9B(M)(L)(Z) A90(L) A93(M)(L)(Z) M9// H0 H4 H5 High temperature type 5 to 150C Solid state auto switch Note) Size 25 is not applicable for H4.

D-C73/D-C76/D-C80 Band Mounting Style. D-B53/D-B54/D-B64 Band Mounting Style . D-C73C/D-C80C Band Mounting Style. D-A72/D-A73/D-A80 Band Mounting Style . D-A7xH/D-A80H Rail Mounting Style. D-A73C/D-A80C Rail Mounting Style . D-A90(V)/D-A93(V)/D-A96(V) Direct Mounting Style . D-Z73/D-Z76/D-Z80 Direct Mounting Style. D-E73A/D-E76A/D-E80A Direct Mounting Style. 2-color Indication Type .

D-A90(V)/D-A93(V)/D-A96(V) Direct Mounting Style .

(mm) Auto Switch Mounting Height D-A9l(V) D-M9l(V) D-M9lW(V) D-M9lA(V) D-H7l D-H7lW D-H7BA D-H7NF D-C7l D-C80 Auto switch model D-B5l D-B64 D-B59W D-G5NT D-H7C D-G39A D-K39A D-A3lA D-A44A D-C73C D-C80C Hs Hs Hs Hs Hs 20 24.5 25.5 25 60 69.5 25 27 28 27.5 62.5 72 32 30.5 31.5 31 66 75.5 40 34.5 35.5 35 70 79.5 Bore size D-X Technical Data 263 CM2 Series Auto Switch Proper Mounting Position

Magnet: Built-in, Mounting: Axial Foot, Style: Aluminum Tube, Bore Size: 50mm, Thread: Rc, Stroke: 125mm, Option: N [w/o Rod Boot, w/o Cushion (Not Valid for Air-hydro), Lock Operation: Spring/Air Pressure Lock, Auto Switch: F59--Solid State, Gen. Purpose, 3 Wire NPN, Lead Wire or Prewied Connector: 3m, Number: -

Magnet: Built-in, Mounting: Axial Foot, Style: Aluminum Tube, Bore Size: 50mm, Thread: Rc, Stroke: 125mm, Option: N [w/o Rod Boot, w/o Cushion (Not Valid for Air-hydro), Lock Operation: Spring/Air Pressure Lock, Auto Switch: J59--Solid State, Gen. Purpose, 2 Wire, Lead Wire or Prewied Connector: 3m, Number: -

Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 125, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: [Included] Presence, Valves: No,

This is a legacy product. Please contact us for the latest version.sales@ocaire.com