M3 M3E m x g FE L2 DFrom above, n = 1 + 2 + 3A + 3B = 0.1 + 0.082 + 0.35 + 0.28 = 0.812 From n = 0.812 1, it is applicable.
Minimum Stroke for Auto Switch Mounting n: Number of auto switches [mm] Auto switch model Number of auto switches 32, 40, 45, 50, 56, 63, 67, 80, 85, 100 2 (Different surfaces, Same surface), 1 15 D-M9m D-M9mW n 15 + 40 (n 2) 2 (n = 2, 4, 6, 8) Note) 2 (Different surfaces, Same surface), 1 10 D-M9mV D-M9mWV n 10 + 30 (n 2) 2 (n = 2, 4, 6, 8) Note) 2 (Different surfaces, Same surface), 1
Load [N] Load [N] MXZ16 MXZ16 MXZ16 0.15 0.15 0.15 Table displacement [mm] Table displacement [mm] Table displacement [mm] ST 25, 30 ST 25, 30 ST 25, 30 ST 15, 20 0.10 0.10 0.10 ST 15, 20 ST 15, 20 ST 5, 10 0.05 0.05 0.05 ST 5, 10 ST 5, 10 0.00 0 5 10 15 20 25 0.00 0 5 10 15 20 25 0.00 0 5 10 15 20 25 Load [N] Load [N] Load [N] MXZ20 MXZ20 MXZ20 0.25 0.40 0.25 ST 35, 40 ST 45, 50 ST 45,
Slider type (Slide bearing type) Number of auto switches Piping Nil S n 2 pcs. Bilateral piping type 1 pc. n pcs. Nil P2 P1 Auto switch Nil Without auto switch Centralized piping type Plate Refer to the table below for the applicable auto switch model. Note) Auto switch rail and magnet for auto switch included as standard.
Bore size 25 32 40 25 mm 32 mm 40 mm Number of auto switches Nil S n 2 pcs. 1 pc. n pcs. Port thread type Bore size Symbol Nil TN TF Type Rc NPT G 25, 32, 40 Auto switch Nil Without auto switch (Built-in magnet) Refer to the table below for the applicable auto switch model.
Action Double acting Fluid Air Operating pressure 0.25 to 0.6 MPa Ambient and fluid temperature 10 to 60C (No freezing) Holding force (Workpiece thickness: 0.6 mm) Symbol Holding force Model 1 80 N MHM-A3201-1-X6400 2 50 N MHM-A3201-2-X6400 3 30 N MHM-A3201-3-X6400 MHM-32D1-X6400 80 N MHM-32D2-X6400 50 N MHM-32D3-X6400 30 N Residual holding force 0.3 N or less Lubrication Non-lube Weight
Number of auto switches Bore size 16 20 25 32 40 50 63 16 mm 20 mm 25 mm 32 mm 40 mm 50 mm 63 mm 2 pcs 1 pc n pcs Nil S n Stroke adjustment unit symbol Refer to Stroke adjustment unit on page 1351. Made to Order Specifications For details, refer to page 1351.
n Mounting Nil Through-hole (Standard) A Both ends tapped Auto switch Nil Without auto switch For applicable auto switches, refer to the table below.
Pressure 0.6 MPa 0.5 40 8 0.5 Gripping force (N) Gripping force (N) 0.4 30 6 0.4 0.3 0.3 20 4 0.2 0.2 10 2 0.1 0.1 0 20 30 50 60 Gripping point L (mm) 40 0 30 40 60 70 Gripping point L (mm) 50 80 MHY2-16D MHY2-25D F F F F 35 100 Pressure 0.6 MPa Pressure 0.6 MPa 30 0.5 0.5 80 25 Gripping force (N) External grip Gripping force (N) 0.4 0.4 60 20 0.3 0.3 15 40 0.2 0.2 10 20 0.1 0.1 5 L L 0 20
Nil N Without arm With arm The overall length Q (from the end on the head side to the rod end) is the same as the MK2 series.
Basic type Bore size 25 32 40 25 mm 32 mm 40 mm Number of auto switches Nil S n 2 pcs. 1 pc. n pcs. Port thread type Type Rc NPT G Symbol Nil TN TF Auto switch Nil Without auto switch (Built-in magnet) Stroke adjustment unit symbol For stroke adjustment unit, refer to page 1189.
Confirm that the external force is 20 [N] or less. (The external force is the resistance due to cable duct, flexible trunking or air tubing.)
Moreover, leakage current flow to the load will be n times larger when n auto switches are connected in parallel. 12. Output operation of the solid state auto switch is not stable for 50 [ms] after powered ON.
E2E-X2D1-N/2-wire Brown 7 30 Load + V 26 13 Proximity switch main circuit DIndicator LED Vinyl insulation round cord 3.5 (18/0.12), 2-wire, Standard 2 m, Cord extension (Individual metal piping), Max. 200 m M8 x 1 Blue Washer with teeth Tightening nut 0 V 3 -X 595 RS2H Series Construction Double acting (DL, DM) !
(N) MGG Note 1) The guide rod and self-weight for the plate are not included in the above displacement values.
] Note 4) 44 44 7 350 Max. instantaneous power consumption [W] Note 5) 123 127 8 400 Type Note 6) Non-magnetizing lock Lock unit specifications 9 450 Holding force [N] 36 10 500 Power consumption [W] Note 7) 5 11 600 Rated voltage [V] 24 VDC10% 12 700 Note 1) Please consult with SMC as all non-standard and non-made-to-order strokes are produced as special orders.
P(MPa) 4. 1. :200(Kg) 2. :20(m/min) 3. :0.5(MPa) 4. :0.1 D 50 : : mmax 1 RS2H mmax : mmax (Kg) =0.1 =0.2 NO 50 400 280 mAm max 63 530 365 YES 80 800 565 V m mmax=0.1 200<400 mP6 -1-* -1-1V=20m/minm=278(Kg) 200278 NO mA m YES FA=mAg FA 2000.19.8 196(N) FAmAg(N) (g: :9.8m/S 2) P F -2-1P=0.5(MPaF=766(N)766(N) 196776 P7 -2-1 NO FA F RS2H50 YES v [m/min] m [kg] -1 5 - -
[The voltage drop will be n times larger when n auto switches are connected.] Even though an auto switch operates normally, the load may not operate. Load In the same way, when operating under a specified voltage, although an auto switch may operate normally, the load may not operate.
0.6 MPa Gripping force (N) 15 15 Gripping force (N) 0.5 MPa 0.5 MPa 0.4 MPa 10 10 0.4 MPa L: Gripping point length (mm) 0.3 MPa 0.3 MPa Indication of effective gripping force The effective gripping force shown in the graphs to the right is expressed as F , which is the thrust of one finger, when three fingers and attachments are in full contact with the workpiece as shown in the figure