SMC Corporation of America
Elite Part Number Search
Search Results "CDQ2A16-5D-A90VLS"

Bore Size: 40mm, Port Thread: TN (NPT), Stroke: 300mm, Auto Switch: A90V--Reed, DC Volt, AC Volt, Vertical, Lead Wire or Prewired Connector: L (3m), Number: S (1 pc.)

Magnet: D (Built-in), Mounting: C (Rear Pivot), Bore Size: 106 (1 1/16"), Stroke: 0050 (1/2"), Cushion: C (Rubber Bumper), Rod Boot: Without Boot, Auto Switch: A90V--Reed, DC Volt, AC Volt, Vertical, Lead Wire or Prewired Connector: L (3m), Number: S (1 pc.)

Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 300, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Guided, Additional Function: Standard / With rod detent function, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Operating Pressure(MPa): -, Cushion: Rubber bumper at both ends, Port thread type: NPT,

Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 50, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Guided, Additional Function: Standard / With rod detent function, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Operating Pressure(MPa): -, Cushion: Rubber bumper at both ends, Port thread type: NPT,

Cylinder (Tube) Inner Diameter(φ): 25, Stroke(mm): 15, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Operating Pressure(MPa): 0.05~1, Cushion: None, Specification: Built-in magnet, Support bracket:

Bore Size: 6mm, Stroke: 100mm, Adjuster: Rubber Stopper, Centralized Piping/Switch Rail: Centralized Piping One Side, w/Switch Rail, Auto Switch: A90V--Reed, DC Volt, AC Volt, Vertical, Lead Wire or Prewired Connector: L (3m), Number: S (1 pc.)

Bore Size: 20mm, Thread Type: Bore 12-25: M Thread; Bore 32-40: Rc, Stroke: 200mm, Cushion: 2 pcs. Adjuster Bolt, Auto Switch: A90V--Reed, DC Volt, AC Volt, Vertical, Lead Wire or Prewired Connector: L (3m), Number: S (1 pc.)

This is a legacy product. Please contact us for the latest version.sales@ocaire.com

SMC has redesigned the NCQ2 compact cylinder with a new body, making it possible to mount auto switches on any of the 4 surfaces, depending on the installation conditions.  Auto switch mounting grooves have replaced the NCQ2's mounting rails, preventing projection of auto switches and improving ease and safety of work.Compact, double acting, single rod, large bore , Bore size (mm): 125, 

Magnet: D (Built-in), Mounting: B (Through Hole, Both Ends Tapped), Bore Size: 12mm, Stroke: 10mm, Action: T (Single Acting Spring Extend), Option: Standard (Rod End Female Thread), Auto Switch: A90V--Reed, DC Volt, AC Volt, Vertical, 0.5M, Lead Wire or Prewired Connector: L (3m), Number: S (1 pc.)

Magnet: D (Built-in), Mounting: D (Double Clevis), Bore: Ø10 (3/8 inch), Stroke: 150 (1 1/2 Inch), Action: S (Spring Return), Port Location: Perpendicular, Auto Switch: A90V--Reed, DC Volt, AC Volt, Vertical, Lead Wire or Prewired Connector: L (3m), Number: S (1 pc.)

Magnet: D (Built-in), Mounting: B (Through Hole, Both Ends Tapped), Bore Size: 25mm, Stroke: 5mm, Option: C (Rubber Bumper), Auto Switch: A90V--Reed, DC Volt, AC Volt, Vertical, 0.5m, Lead Wire or Prewired Connector: L (3m), Number: S (1 pc.)

Bore Size: 8mm, Symmetric Type: L (Symmetric), Stroke: 10mm, Adjuster: A (Both Sides Adjusters/Rubber Stoppers), Function: Standard, Auto Switch: A90V--Reed, DC Volt, AC Volt, Vertical, 0.5M, Lead Wire or Prewired Connector: L (3m), Number: S (1 pc.)

Bore Size: 8mm, Symmetric Type: Standard, Stroke: 10mm, Adjuster: A (Both Sides Adjusters/Rubber Stoppers), Function: Standard, Auto Switch: A90V--Reed, DC Volt, AC Volt, Vertical, 0.5M, Lead Wire or Prewired Connector: L (3m), Number: S (1 pc.)

This is a legacy product. Please contact us for the latest version.sales@ocaire.com

This is a legacy product. Please contact us for the latest version.sales@ocaire.com

Bore Size: 8mm, Port Thread: Rc, Stroke: 10mm, Adjuster: AS (Adjuster on Extension End), Function: Standard, Auto Switch: A90V--Reed, DC Volt, AC Volt, Vertical, 0.5M, Lead Wire or Prewired Connector: L (3m Lead Wire), Number: S (1 pc.)

Bore Size: 16mm, Port Thread: Rc, Stroke: 50mm, Adjuster: AS (Adjuster on Extension End), Function: Standard, Auto Switch: A90V--Reed, DC Volt, AC Volt, Vertical, 0.5M, Lead Wire or Prewired Connector: L (3m Lead Wire), Number: S (1 pc.)

The solution for a linear-actuator subject to high loads. Ideal for material handling applications. Two basic models include a self-lubricating slide bushing and a linear ball bearing style. The 100mm slide bushing model can stop a load of 3,000 lbs. traveling at 55ft/min, or smoothly lift a centered load of 1,000 lbs. with a 40% safety factor. The overall package is very compact, and pre-tapped

The solution for a linear-actuator subject to high loads. Ideal for material handling applications. Two basic models include a self-lubricating slide bushing and a linear ball bearing style. The 100mm slide bushing model can stop a load of 3,000 lbs. traveling at 55ft/min, or smoothly lift a centered load of 1,000 lbs. with a 40% safety factor. The overall package is very compact, and pre-tapped