Body Through-hole l l Maximum tightening torque (Nm) Max. screw-in l (mm) Bolt Model 2. If intermediate stops by external stopper is done, avoid ejection. If lurching occurs damage can result.
Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 25, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, Operating Pressure(MPa): 0.05~1, Cushion: None, Specification: Built-in magnet, Support bracket:
Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 25, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, Operating Pressure(MPa): 0.05~1, Cushion: None, Specification: Built-in magnet, Support bracket:
Magnet: D (Built-in), Mounting: B [Through Hole (Standard)], Type: Standard, Bore Size: 50mm, Port Thread Type: TN (NPT 32-100 Bore), Stroke: 25mm, Body Option: Standard (Rod End Female Thread, Without thread on 4mm bore), Auto Switch Groove: Z (Auto Switch Mounting Grooves)
, D-Z76, D-Z80 A B A B CHQ Auto switch mounting screw M2.5 x 4 L CHK CHK (Attached to the auto switch) M3 x 6 L CHN M3 x 6 L Auto switch (Attached to BHK2-032) (Attached to BHK2-032) CHM Auto switch mounting bracket BMG2-012 CHS Auto switch mounting bracket Auto switch mounting bracket BHK2-032 BHK2-032 CH2 CHA Related Products D1.
Lead Wire Length Lead wire length designation (example) D-A73 L Lead wire length Nil L Z NNote) 0.5m 3m 5m None Note) Applies only to D C type connector switches.
Load voltage Auto switch model Lead wire length (m) Pre-wired connector 0.5 (Nil) Indicator light Wiring (Output) Special function Type Electrical entry Applicable load 3 (L) 5 (Z) AC DC Perpendicular In-line 3-wire IC circuit 5 V A96V A96 Yes Reed switch Solid state switch (NPN equivalent) Grommet 100 V 24V 12 V 5 V, 12 V A93 A90 M9N M9P M9B F9NW F9PW F9BW A93V A90V M9NV M9PV M9BV F9NWV
Applicable bore size Dd9 d L L1 m t Included retaining ring Part no.
10 16 12 4 MXQ-CT12(L)-X11 15 32 G MXQ-CT12(L)-X12 25 42 B C MXQ-CT16(L) 5 23 J MXQ16(L) M10 x 1 M5 x 12 MXQ-CT16(L)-X11 15 33.5 35.5 20 12 17 14 5 33 MXQ-CT16(L)-X12 25 43 A K MXQ-CT20(L) 5 27 MXQ20(L) MXQ-CT20(L)-X11 M5 x 14 M12 x 1.25 15 41 44.5 25 23 37 13 17 6 MXQ-CT20(L)-X12 25 47 MXQ-CT25(L) 5 30 MXQ25(L) M14 x 1.5 M6 x 18 MXQ-CT25(L)-X11 15 40 49 53.5 31 15 28 19 6 MXQ-CT25(L)-X12
Port variations Applicable cylinder MY2C16/25/40 MY2H16/25/40 MY2HT16/25/40 R R L L L L L L L L R R R R R R L R Slide table operating direction 40 Series MY2 Auto Switch Precautions 1 Be sure to read before handling. Design and Selection Warning 1. Confirm the specifications.
A22 Symbol: A23 Symbol: A24 30 30 DA L RD MM 30 MM DA 30 MM MM DB DB T T C B A H AL H A L K H A A W H H Symbol: A25 Symbol: A26 Symbol: A27 Symbol: A28 Symbol: A29 DA 30 MM MM DA 30 DA 30 30 MM L W MM A L H AL H LB K A AL A H L A H T AL L K H MM Symbol: A30 30 MM W A T H 84 Simple Specials Series CP96/C96 Symbol Change of Trunnion Bracket Mounting Position 2 -XC14 Series C85 Series
Grease pack GR-L-005 (5 g) GR-L-010 (10 g) GR-L-150 (150 g) RB Operating Precautions J Warning 1. It might not be able to control CUX10 by meter-out at a low speed operation. DCaution -X 1.
Grease pack GR-L-005 (5 g) GR-L-010 (10 g) GR-L-150 (150 g) RB Operating Precautions J Warning 1. It might not be able to control CUX10 by meter-out at a low speed operation. DCaution -X 1.
Size: 30/50/63/80/100 Single shaft with four chamfers: ClRA1BX Double shaft with key: ClRA1BY Double shaft with four chamfers: ClRA1BZ L 0 0.2 L 0 0.2 0 0.1 0 0.1 G G N N H H H U U UU UU M N H L K 0 0.2 G D L 0 0.2 [mm] [mm] [mm] Size G H N U L 30 6 13 8 53 7.8 50 11 27 15 89 14 63 13 29 17 105 16 80 15 38 20 130 19 100 19 44 25 156 24 Size H K UU L 30 25 3 90 14 50 36 5 134 25 63 41 5 158
Vibrations on guide and moving part resistance will result when power over the allowable moment is applied. rFlatness of mounting surface should be less than 0.02mm. l l l allowable load and allowable moment. Refer to p.3.11-10 and 3.11-11 for the details.
C X L + Stroke 20 20 CH2 5 + Stroke 57 + Stroke 5 67 + 2 strokes CHA Related Products 32 to 100 2 x P (port size) H with effective thread depth C 4 x N through hole 8 x O counter bore DF F I I D D M E Z K M E J B + Stroke L + Stroke A + 2 strokes L Note) The auto switches above are shown for a D-M9(W) solid state auto switch.