Applicable model Note Quantity AS-10D ZH05/07/10DA Applicable thread size: M3 1 pc. AS-25D ZH13/15DA Applicable thread size: M4 AS-30D ZH18/20DA Applicable thread size: M4 1 DIN rail is not included. It should be provided by the customer. DIN rail mounting bracket DIN rail Provided by customer eSet of Long Clamping Screws1 Part no.

.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 30 M26 x 1.5 21 83 4 x 30l Polished round 20 37 38 40 20 83 61 100 Y-10D +0.3 +0.1 MB Knuckle pin, cotter pin and flat washer are included.

Type Note 5) The made-to-order, heat resistant auto switch -XB14 is not applicable. Nil S n 2 pcs. 1 pc. n pcs. Pneumatic Air-hydro Note 1) Nil Made to Order Refer to the next page for details. H Note 1) Bore sizes available for airhydro type are 20 to 100.

Magnet: Built-in Magnet, Mounting: Through-hole, Standard, Bore Size: 20mm, Port Thread: Rc: 32-100 Bore; M Thread 12 to 25 Bore, Stroke: 10mm, Body Option: Standard, Rod End Female Thread, Auto Switch Groove: None (for 12-25 Bore w/o Magnet; 32-100 Bore w/o Magnet Z must be selected), Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number

Magnet: Built-in Magnet, Mounting: Through-hole, Standard, Bore Size: 32mm, Port Thread: Rc: 32-100 Bore; M Thread 12 to 25 Bore, Stroke: 10mm, Body Option: Standard, Rod End Female Thread, Auto Switch Groove: None (for 12-25 Bore w/o Magnet; 32-100 Bore w/o Magnet Z must be selected), Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number

Magnet: Built-in Magnet, Mounting: Through-hole, Standard, Bore Size: 50mm, Port Thread: Rc: 32-100 Bore; M Thread 12 to 25 Bore, Stroke: 10mm, Body Option: Standard, Rod End Female Thread, Auto Switch Groove: None (for 12-25 Bore w/o Magnet; 32-100 Bore w/o Magnet Z must be selected), Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number

Magnet: Built-in Magnet, Mounting: Through-hole, Standard, Bore Size: 63mm, Port Thread: Rc: 32-100 Bore; M Thread 12 to 25 Bore, Stroke: 10mm, Body Option: Standard, Rod End Female Thread, Auto Switch Groove: None (for 12-25 Bore w/o Magnet; 32-100 Bore w/o Magnet Z must be selected), Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number

SMC solves these limitations with our XB14 option, the markets original compact cylinder with the D-F7NJ heat resistant switch. Special seals and heat resistant grease allow this product to be placed on designs located in environments up to 300F, making high temperature environments no longer a restriction.

Indicator light Sensor section: 0 to 150C Amplifier section: 0 to 60C Precautions Caution Ambient temperature Sensor section: 1000 m/s2 Amplifier section: 300 m/s2 Impact resistance Auto switch which can be mounted on heat resistant, compact cylinder, CDQ2-XB14. For using for other cylinders, please confirm SMC.

40 50 63 CDQ2 Compact cylinder CDQ2-XB14 Double acting, Single rod Except with rubber bumper Series D-M9 J 15-E644

Yes, it is available using the special order part number suffix “-XB14.” The product is a combination of a heat-resistant CDQ2 series cylinder (bore sizes ø16 to ø63) and a heat-resistant auto switch for the CDQ2.
The “-XB14” uses an “-XB6” heat-resistant cylinder (with heat-resistant seal material and grease) with a built-in heat-resistant magnet (for CDQ2 series cylinders).

SMC has redesigned the CQ2 compact cylinder with a new body, making it possible to mount auto switches on any of the 4 surfaces, depending on the installation conditions. Auto switch mounting grooves have replaced the CQ2s mounting rails, preventing projection of auto switches and improving ease and safety of work.Single acting, single rod, compact cylinder , Bore sizes *: 12, 16, 20, 25

SMC has redesigned the NCQ2 compact cylinder with a new body, making it possible to mount auto switches on any of the 4 surfaces, depending on the installation conditions.  Auto switch mounting grooves have replaced the NCQ2's mounting rails, preventing projection of auto switches and improving ease and safety of work.Compact, double acting, single rod, large bore , Bore size (mm): 125,