Lead wire length symbols: 0.5 mNil (Example) M9N 3 m L (Example) M9NL 5 m Z (Example) M9NZ Refer to page 10-12-16 for details on other applicable auto switches than listed above.
, 12 V A93 A90 M9N M9P M9B F9NW F9PW F9BW A93V A90V M9NV M9PV M9BV F9NWV F9PWV F9BWV 2-wire Relay, PLC IC circuit 100 V or less No 3-wire (NPN) IC circuit 5 V, 12 V 3-wire (PNP) 2-wire 12 V Grommet Relay, PLC Yes 24V 3-wire (NPN) 3-wire (PNP) IC circuit 5 V, 12 V Diagnostic indication (2-color indication) 2-wire 12 V Lead wire length symbols: 0.5 mNil (Example) M9N 3 mL (Example) M9NL
Solid state switch Yes Yes Grommet Relay, PLC A93 A93V 2-wire 12 V 24 V 100 V M9N M9NV 3-wire (NPN) IC circuit 5 V, 12 V M9P M9PV 3-wire (PNP) Relay, PLC M9B M9BV 2-wire 12 V 24 V Grommet F9NW F9NWV 3-wire (NPN) 5 V, 12 V Diagnostic indication (2-color indication) F9PW F9PWV 3-wire (PNP) F9BW F9BWV 2-wire 12 V Lead wire length symbols: 0.5 mNil (Example) M9N 3 m L (Example) M9NL
Lead wire length symbols:0.5 m Nil (Example) M9N 3 m L (Example) M9NL 5 m Z (Example) M9NZ Refer to page 12-13-25 for solid state switch with pre-wire connector. 12-5-4 5 2 Finger Rotary Actuated Air Gripper Series MHR2/MDHR2 30 Model/Specifications Nominal size 10 15 20 Action Double acting Gripping force (N) (1) External grip 12 24 33 58 (Effective value) at 0.5 MPa Internal grip 12 34
(Including insulating material) 2.55 mm Connection type Spring-cage connection Rated current 4 A Rated voltage 60 V 48 V 60 V Contact resistance 5 m or less Insulation resistance 100 M or more Withstand voltage 1.4 kV Rating/Performance Ambient temperature Connector 25 to +90C 40 to +85C 25 to +90C Cable 40 to +85C Min. bending radius (Fixed) 78 mm Protection class IP67 (Only with
The fluid and ambient temperatures range for the switch is 0 to 50C (and 0 to 90C for high temperature fluid). Take measures to prevent the fluid from freezing when it is below 5C, since this may cause damage to the switch and lead to a malfunction.
Please contact SMC. 3) 14 to 194F (10 to 90C) for Vespel seat. Optional ambient and operating temperature range available. Please contact SMC. 4) Mass, including individual boxed weight, may vary depending on connections or options. Hastelloy is a registered trademark of Haynes International.
How to Order Integrated Display Type PF2W7 20 T 03 27 Flow rate range Unit specification T Temperature range 0.5 to 4 l/min 2 to 16 l/min 5 to 40 l/min 04 20 40 0 to 90C Nil M With unit switching function Lead wire (Refer to page 35.)
(0.7 MPa) source pressure drop Bottom mount (Option: panel mount) 0.49 in3 (8 cm3) 2.76 lbs (1.25 kg) 5) Proof pressure (Inlet) Burst pressure Ambient and operating temperature Cv Inboard leakage Outboard leakage Leak rate Across the seat leak Surface finish Connections Supply pressure effect Installation Internal volume Mass 1) Max 300 psig (2.1MPa) for PTFE seat. 2) 14 to 194F (10 to 90C
Specifications AP3260 Select compatible materials of construction for the gas Vacuum to 125 psig (0.9 MPa) 1000 psig (6.9 MPa) 8000 psig (55.2 MPa) 40 to 194F (40 to 90C) (No freezing) 0.27 2 x 10-11 Pam3/sec 2 x 10-10 Pam3/sec 1) 1 x 10-7 Pam3/sec 1) Ra max 15 in. (0.4 m) Option: 10 in. (0.25 m), 7 in. (0.18 m), 5 in. (0.13 m) Face seal, Tube weld Bottom mount (Option: panel mount) 0.06
pressure per 20 psig (0.14 MPa) source pressure drop Bottom mount 0.19 in3 (3.1 cm3) 0.99 lbs (0.45 kg) 3) Delivery pressure Gas Source pressure Proof pressure (Inlet) Burst pressure Ambient and operating temperature Cv Inboard leakage Outboard leakage Leak rate Across the seat leak Surface finish Connections Supply pressure effect Installation Internal volume Mass 1) 14 to 194F (10 to 90C
The compatibility shown in the table is when the fluid temperature is within the product specification (90C or less). Chemical Note 1) Static electricity may be generated. Take measures to prevent static electricity. Note 2) Fluid may permeate through and affect parts made of other materials. 620
Switching from real-time flow rate to accumulated flow is possible.Digital flow switch for high temperature fluids , Integrated display type , Temperature range: 0 to 90C , Flow rate range: 0.5-4(l/min) ~ 5-40(l/min) , PNP/NPN open collector 2 outputs , Port sizes: 3/8, 1/2, 3/4, DIGITAL FLOW SW, INTEG SENSOR, INSTRUMENTATION, IFW/PFW FLOW SWITCH, EA, IFW/PFW 3/8INCH PT VERSION, 2.08890
Switching from real-time flow rate to accumulated flow is possible.Digital flow switch for high temperature fluids , Integrated display type , Temperature range: 0 to 90C , Flow rate range: 0.5-4(l/min) ~ 5-40(l/min) , PNP/NPN open collector 2 outputs , Port sizes: 3/8, 1/2, 3/4, DIGITAL FLOW SWITCH,COMBO UNIT, INSTRUMENTATION, IFW/PFW FLOW SWITCH, 2X, IFW/PFW NO SIZE ALL OTHER, 2.40768
Switching from real-time flow rate to accumulated flow is possible.Digital flow switch for high temperature fluids , Integrated display type , Temperature range: 0 to 90C , Flow rate range: 0.5-4(l/min) ~ 5-40(l/min) , PNP/NPN open collector 2 outputs , Port sizes: 3/8, 1/2, 3/4, DIGITAL FLOW SW, INTEG SENSOR, INSTRUMENTATION, IFW/PFW FLOW SWITCH, EX, IFW/PFW 3/8INCH ALL OTHERS, 2.11643
Switching from real-time flow rate to accumulated flow is possible.Digital flow switch for high temperature fluids , Integrated display type , Temperature range: 0 to 90C , Flow rate range: 0.5-4(l/min) ~ 5-40(l/min) , PNP/NPN open collector 2 outputs , Port sizes: 3/8, 1/2, 3/4, DIGITAL FLOW SW, INTEG SENSOR, INSTRUMENTATION, IFW/PFW FLOW SWITCH, EX, IFW/PFW 3/8INCH ALL OTHERS, 2.20462
Switching from real-time flow rate to accumulated flow is possible.Digital flow switch for high temperature fluids , Integrated display type , Temperature range: 0 to 90C , Flow rate range: 0.5-4(l/min) ~ 5-40(l/min) , PNP/NPN open collector 2 outputs , Port sizes: 3/8, 1/2, 3/4, DIGITAL FLOW SW, INTEG SENSOR, INSTRUMENTATION, IFW/PFW FLOW SWITCH, EX, IFW/PFW 3/8INCH ALL OTHERS, 1.77719
Switching from real-time flow rate to accumulated flow is possible.Digital flow switch for high temperature fluids , Integrated display type , Temperature range: 0 to 90C , Flow rate range: 0.5-4(l/min) ~ 5-40(l/min) , PNP/NPN open collector 2 outputs , Port sizes: 3/8, 1/2, 3/4, DIGITAL FLOW SW, INTEG SENSOR, INSTRUMENTATION, IFW/PFW FLOW SWITCH, EB, IFW/PFW 3/8INCH NPT VERSION, 1.98416
Switching from real-time flow rate to accumulated flow is possible.Digital flow switch for high temperature fluids , Integrated display type , Temperature range: 0 to 90C , Flow rate range: 0.5-4(l/min) ~ 5-40(l/min) , PNP/NPN open collector 2 outputs , Port sizes: 3/8, 1/2, 3/4, DIGITAL FLOW SW, INTEG SENSOR, INSTRUMENTATION, IFW/PFW FLOW SWITCH, EB, IFW/PFW 3/8INCH NPT VERSION, 1.62533
Switching from real-time flow rate to accumulated flow is possible.Digital flow switch for high temperature fluids , Integrated display type , Temperature range: 0 to 90C , Flow rate range: 0.5-4(l/min) ~ 5-40(l/min) , PNP/NPN open collector 2 outputs , Port sizes: 3/8, 1/2, 3/4, DIGITAL FLOW SW, INTEG SENSOR, INSTRUMENTATION, IFW/PFW FLOW SWITCH, EB, IFW/PFW 3/8INCH NPT VERSION, 1.56528