Cylinder stroke (mm) Long stroke (mm) 35, 40, 45, 50, 75, 100 Bore size (mm) Standard stroke (mm) 5, 10, 15, 20, 25, 30 Action D Double acting 12, 16 75, 100, 125, 150, 175, 200 75, 100, 125, 150, 175, 200, 250, 300 20 5, 10, 15, 20, 25, 30, 35, 40, 45, 50 25 Applicable Auto Switches/Refer to p.5.3-2 for further information on auto switch.
188 313 150 163 288 125 138 263 23 100 113 238 36 75 100 213 54 12.5 37.5 50 88 54 4 17 75 250 225 200 175 188 313 150 163 288 125 138 263 23 100 113 238 36 75 100 213 54 12.5 25 37.5 50 88 69 5 24 87 250 225 200 175 200 325 150 175 300 125 150 275 25 100 125 250 51 75 112 225 64 12.5 25 37.5 50 100 69 5 24 87 250 225 200 175 200 325 150 175 300 125 150 275 25 100 125 250 51 75 112 225 64
P N Ground ball screw Rolled ball screw Specifications Combinations other than the above cannot be manufactured.
/s) 50 1200 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500, 600 C85 -XC3 Special port location 63 1200 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500, 600 -XC4 With heavy duty scraper C95 80 1400 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500, 600, 700, 800 Heat resistant cylinder (110 C) -XC5 100 1500 25, 50, 75, 100, 125, 150, 175
/s) 50 1200 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500, 600 C85 -XC3 Special port location 63 1200 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500, 600 -XC4 With heavy duty scraper C95 80 1400 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500, 600, 700, 800 Heat resistant cylinder (110 C) -XC5 100 1500 25, 50, 75, 100, 125, 150, 175
Series VQ1000 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Plug Lead Plug-in Cassette P. 2-4-12 P. 2-4-14 P/J kit Series VQ0 P R SMC P. 2-4-38 P. 2-4-42 P. 2-4-46 P kit Series VQ1000 P. 2-4-38 P. 2-4-42 P. 2-4-46 P kit Series VQ2000 P. 2-4-38 P. 2-4-42 P. 2-4-46
IDF-BP303 IDF-BP311 IDF4E IDF4E 531 560 595 110 2.3 595 110 2.4 175 175 1/2 1/2 I D F I D F IDF6E IDF6E 555 587 617 617 IDF-BP304 IDF-BP312 IDF8E IDF8E 129 3.3 129 3.4 187 182 3/4 3/4 627 659 647 647 31 31 IDF11E IDF11E IDU-BP305 IDU-BP306 IDU-BP307 IDU-BP313 IDU-BP314 IDU-BP315 506 530 572 572 100 1.6 100 1.7 202 192 IDU3E IDU3E 3/8 3/8 I D U I D U 603 632 625 625 110 2.3 110 2.4 175 175
For stopping accuracy, refer to Series CLJ (P. 9-2-12), Series CLM2 (P. 9-2-20), Series CLG1 (P . 9-2-30), and Series CL1 (P . 9-3-2) respectively. 7. In order to further improve stopping accuracy, the time from the stop signal to the operation of the lock should be shortened as much as possible.
For stopping accuracy, refer to Series CLJ (P. 9-2-12), Series CLM2 (P. 9-2-20), Series CLG1 (P . 9-2-30), and Series CL1 (P . 9-3-2) respectively. 7. In order to further improve stopping accuracy, the time from the stop signal to the operation of the lock should be shortened as much as possible.
] The distance of switch ON [mm] The distance of switch ON [mm] 0.25 mm 0.05 mm 0.5 mm 0.05 0.25 0.50 0.04 0.20 0.40 0.15 mm 0.3 mm 0.03 mm 0.03 0.15 0.30 0.02 0.10 0.20 0.01 mm 0.01 0.05 0.10 0.05 mm 0.02 mm 0 0 0 Supply pressure [kPa] 75 100 125 150 175 200 225 Supply pressure [kPa] 75 100 125 150 175 200 225 Supply pressure [kPa] 75 100 125 150 175 200 225 10 ISA3 Series Response Time
P P P Lock position Z80 P P H R Rear lock Front lock Y59A Y69A P p P Manual release Y7PV Y7P P P p N L Non-locking type Locking type Y59B Y69B P p P Solid state switch Y7NW Y7NWV P P p Y7PW Y7PWV P P p Y7BW Y7BWV P P p Y7BA P p Lead wire symbols 0.5m . Nil (Example) Y69B 3m . L Y69BL 5m . Z Y69BZ Solid state switches marked with a "p" are produced upon receipt of order.
metal name plate IDF100F to 150F IDFmF-m-P p. 30 IDF4E to 75E IDFmE-m-R Refrigerant R407C (HFC) IDF D p. 31 IDF100F to 150F IDFmF-m-R With an earth leakage breaker IDF190D to 370D IDFmD-3-R IDU3E to 75E IDUmE-m-R Power supply terminal block connection IDF1E to 15E1-10 IDFmE-10-S IDU3E to 15E1-10 IDUmE-10-S With a terminal block for power supply, operating, and error signals*3 IDF4E to 75E
. 10-12-8 P . 10-12-30 P . 10-12-18 P . 10-12-27 10-12-1 2 Achieve rationalization of production lines with position feedback Stroke reading cylinder Measurement is possible throughout the full stroke range.
. 10-12-8 P . 10-12-30 P . 10-12-18 P . 10-12-27 10-12-1 2 Achieve rationalization of production lines with position feedback Stroke reading cylinder Measurement is possible throughout the full stroke range.
rev) Power consumption [W] Note 7) Horizontal 45 65 65 Vertical 145 175 175 Electric specifications Standby power consumption when operating [W] Note 8) Horizontal 2 2 2 Vertical 8 8 8 Max. instantaneous power consumption [W] Note 9) 445 724 724 Type Note 10) Non-magnetizing lock Non-magnetizing lock Holding force [N] 131 255 485 157 308 588 197 385 736 Power consumption at 20C [W] Note 11
" SO, "63 a.5 25, 50, 75, 100,125, 150, 175, 200, 250.300, 350. 400. 450, 500 40 " !
Refer to p.3.4-14. Auto Switch Mounting Bracket Part No.
, 200, 250, 300, 350, 400, 450, 500 C95 40 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500 50 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500, 600 CA1 63 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500, 600 CS1 80 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500, 600, 700, 800 100 25, 50, 75, 100, 125, 150, 175, 200, 250
111.5 15 15 20 12 18 25 16 22 25 49 56.5 66 M6 X 1.0 M8 X 1.25 M8 X 1.25 22 26 32 58 54 62 39 46 56 M10 X 1.5 M12 X 1.75 M14 X 2.0 8.6 10.6 12.5 25, 50, 75, 100, 125, 150, 175, 200 (mm) Bore size (mm) OB OL P PA PB PW Q RA RB RC S SA SB T U VA VB WA WB 50, 75, 100st Larger than 100st 25st 50, 75, 100st Larger than 100st 25st 117 128 168 55 74 89 54 56 71 100 125 150 24 24 35 188 225 272