Model: MSQ, Precision: B (Basic), Size: 70, Suffix: A (Adjuster Bolt), Auto Switch: M9BW--Solid State, 2-color Indication, 2 Wire, Lead Wire or Prewired Connector: L (3m)
Model: MSQ, Precision: B (Basic), Size: 70, Suffix: R (Shock Absorbers), Auto Switch: M9BW--Solid State, 2-color Indication, 2 Wire, Lead Wire or Prewired Connector: SDPC (0.5m Cord Length, M12-4 Pin Connector)
Magnet: D (Built-in Magnet), Bore Size: 25 mm, Port Thread: M5x0.8; Rc1/8 for ø32, Stroke: 70 mm, Auto Switch: M9BW--Solid State, 2-color Indication, 2 Wire, Lead Wire or Prewired Connector: L (3 m), Number: S (1 pc.)
Magnet: D (Built-in Magnet), Bore Size: 25 mm, Port Thread: M5x0.8; Rc1/8 for ø32, Stroke: 70 mm, Auto Switch: M9BW--Solid State, 2-color Indication, 2 Wire, Lead Wire or Prewired Connector: SAPC (0.5 m Cord Length, M8-3 Pin Connector), Number: S (1 pc.)
Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 800, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): 0~70, End Locking: [Included] Presence, Valves: No, Operating Pressure
Cylinder (Tube) Inner Diameter(φ): 125, Stroke(mm): 250, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): 0~70, End Locking: [Included] Presence, Valves: No, Operating Pressure
Cylinder (Tube) Inner Diameter(φ): 125, Stroke(mm): 250, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): 0~70, End Locking: [Included] Presence, Valves: No, Operating Pressure
Cylinder (Tube) Inner Diameter(φ): 125, Stroke(mm): 500, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: With fall prevention function / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): 0~70, End Locking: [Included] Presence, Valves: No, Operating Pressure
Cylinder (Tube) Inner Diameter(φ): 63, Stroke(mm): 200, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): 0~70, End Locking: [Included] Presence, Valves: No, Operating Pressure
Cylinder (Tube) Inner Diameter(φ): 100, Stroke(mm): 100, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: With fall prevention function / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): 0~70, End Locking: [Included] Presence, Valves: No, Operating Pressure
: M9BW, Lead Wire Length(m): 0.5, The number of the switches: 2, Type of Auto Switch Mounting: Standard, Head Cover Port Position: 90° to axis, Pivot Bracket: Without bracket, Rod End Bracket: Without bracket, Type of Mount Support: Basic type, Custom-made Specifications: None, Lock unit magnet: Built-in magnet
: M9BW, Lead Wire Length(m): 3, The number of the switches: 1, Type of Auto Switch Mounting: Band mounting, Head Cover Port Position: 90° to axis, Pivot Bracket: Without bracket, Rod End Bracket: Without bracket, Type of Mount Support: Basic type, Custom-made Specifications: None, Lock unit magnet: Built-in magnet
: M9BW, Lead Wire Length(m): 0.5, The number of the switches: 2, Type of Auto Switch Mounting: Rail mounting, Head Cover Port Position: 90° to axis, Pivot Bracket: Without bracket, Rod End Bracket: Without bracket, Type of Mount Support: Rod-end flange type, Custom-made Specifications: None, Lock unit magnet: Built-in magnet
: M9BW, Lead Wire Length(m): 0.5, The number of the switches: 2, Type of Auto Switch Mounting: Band mounting, Head Cover Port Position: 90° to axis, Pivot Bracket: Without bracket, Rod End Bracket: Without bracket, Type of Mount Support: Rod-end flange type, Custom-made Specifications: None, Lock unit magnet: Built-in magnet
: M9BW, Lead Wire Length(m): 3, The number of the switches: 2, Type of Auto Switch Mounting: Rail mounting, Head Cover Port Position: 90° to axis, Pivot Bracket: Without bracket, Rod End Bracket: Without bracket, Type of Mount Support: Rod-end flange type, Custom-made Specifications: None, Lock unit magnet: Built-in magnet
: M9BW, Lead Wire Length(m): 3, The number of the switches: 2, Type of Auto Switch Mounting: Band mounting, Head Cover Port Position: 90° to axis, Pivot Bracket: Without bracket, Rod End Bracket: Without bracket, Type of Mount Support: Rod-end flange type, Custom-made Specifications: None, Lock unit magnet: Built-in magnet
: M9BW, Lead Wire Length(m): 3, The number of the switches: 1, Type of Auto Switch Mounting: Band mounting, Head Cover Port Position: 90° to axis, Pivot Bracket: Without bracket, Rod End Bracket: Without bracket, Type of Mount Support: Double foot type, Custom-made Specifications: None, Lock unit magnet: Built-in magnet
cushions on both sides, Operating Pressure(MPa): -, Specification: -, Support bracket: Basic type, Port thread type: G, Auto Switches: M9BW, Lead Wire Length(m): 0.5, The number of the switches: 2, Type of Auto Switch Mounting: DPC, Rod Boot: Without rod boot, Tube Material: Aluminum tube, Custom-made Specifications: None, Locking Direction: Bidirectional
Cylinder (Tube) Inner Diameter(φ): 140, Stroke(mm): 200, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: With fall prevention function, Environment, Applications: Standard, Operating Temperature(°C): 0~70, End Locking: [Included] Presence, Valves: No, Operating Pressure(MPa): 0.08~0.97, Cushion: With
Cylinder (Tube) Inner Diameter(φ): 125, Stroke(mm): 60, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: With fall prevention function, Environment, Applications: Standard, Operating Temperature(°C): 0~70, End Locking: [Included] Presence, Valves: No, Operating Pressure(MPa): 0.08~0.97, Cushion: With