D-J51: 5 ms or less Except D-J51 (1 mA or less at 100 VAC, 1.5 mA or less at 200 VAC), D-M5NW/M5PW/M5BW, D-F9BAL, D-P5DWL (1 mA or less at 24 VDC).
D-J51: 5 ms or less Except D-J51 (1 mA or less at 100 VAC, 1.5 mA or less at 200 VAC), D-M5NW/M5PW/M5BW, D-F9BAL, D-P5DWL (1 mA or less at 24 VDC).
Weight (g) Applicable bore size(mm) Weight Applicable bore size(mm) Weight Auto switch model Auto switch model D-A33C-4, A34C-4 D-A33C-5, A34C-5 D-A33C-6, A34C-6 D-A33C-8, A34C-8 D-A33C-10, A34C-10 D-A44C-4 D-A44C-5 D-A44C-6 D-A44C-8 D-A44C-10 162 166 184 210 232 160 164 182 208 230 40 50 63 80 100 40 50 63 80 100 Dimensions (mm) T Applicable bore size (mm) 40 50 63 80 100 C 44 52 64 78 92
75, 100, 125, 150 175, 200 75, 100, 125, 150 175, 200, 250, 300 25 Standard Non-rotating Rod Anti-lateral Load Reed switch D-A90/A90V D-A93/A93V D-A96/A96V Series CQSW 12 16 5, 10, 15, 20 25, 30 7-4-20 20 25 5, 10, 15, 20 25, 30, 35, 40 45, 50 Series CQS 12, 16 20, 25 12 16 20 25 5, 10 7-4-12 Solid state switch D-M9N/M9NV D-M9P/M9PV D-M9B/M9BV D-F9NW/F9NWV D-F9PW/F9PWV D-F9BW/F9BWV D-F9BAL
32, 40, 50 63, 80, 100 Double acting 32 to 40/5 to 100 50 to 100/10 to 100 7-6-132 With End Lock 20, 25, 32 50, 63, 80 100 Single rod CBQ2 Double acting 20 to 63/10 to 100 80, 100/25 to 100 7-6-142 Air-hydro (Bore size 20 to 100) Clean Series (Bore size 12 to 63) Built-in One-touch fittings (Bore size 32 to 63) Foot/Flange style Double clevis style Copper-free 7-6-1 2 Compact Cylinder: Standard
50 75 100 125 40 56 41 23 12.5 25 37.5 50 75 100 125 50 64 51 25 12.5 25 37.5 50 75 100 125 150 63 64 51 25 12.5 25 37.5 50 75 100 125 150 80 68 56 29 12.5 25 37.5 50 75 100 125 150 175 200 100 76 61 29 12.5 25 37.5 50 75 100 125 150 175 200 125 82 75 27 10 20 30 40 60 80 100 120 140 160 180 200 [mm] Rubber Bumper Bore size [mm] h 1 to 50 51 to 100 101 to 150 151 to 200 201 to 300 301
) Backup plate Special resin Guide roller B Special resin Guide roller A Stainless steel (80, 100) MX #6 Special resin (63 to 100) #7 #8 #9 MTS End cover Nickel plated (80, 100) y Carbon steel (80, 100) (80, 100) Wear ring Special resin u i o !
70 100 1000 70 100 1000 Stroke (mm) Stroke (mm) Stroke (mm) 2.
4 150, 200, 250, 300 3/8 1/2 25, 50, 75, 100, 125, 150, 200 100 Non-lube Double acting, Double rod (40 to 63) 20 25 32 40 50 63 80 100 1/8 25, 50, 75, 100, 125, 1/4 150, 200, 250, 300 3/8 1/2 Suction Flow Rate of Vacuum Suction Type (Reference values) Specifications Bore size (mm) Item 20 25 32 40 50 63 80 100 Size Suction flow rate L/min (ANR) 20/25/32/40 50/63/80/100 1.5 MPa 1.0 MPa
Cylinder (Tube) Inner Diameter(φ): 25, Stroke(mm): 10, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Guided, Additional Function: Cylinder with functions of thrusting and boosting, Environment, Applications: Standard, Cushion: Rubber bumper at both ends, Operating Pressure(MPa): 0.05 to 0.7, Specification: Built-in magnet, Port
Cylinder (Tube) Inner Diameter(φ): 25, Stroke(mm): 20, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Guided, Additional Function: Cylinder with functions of thrusting and boosting, Environment, Applications: Standard, Cushion: Rubber bumper at both ends, Operating Pressure(MPa): 0.05 to 0.7, Specification: Built-in magnet, Port
Cylinder (Tube) Inner Diameter(φ): 25, Stroke(mm): 30, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Guided, Additional Function: Cylinder with functions of thrusting and boosting, Environment, Applications: Standard, Cushion: Rubber bumper at both ends, Operating Pressure(MPa): 0.05 to 0.7, Specification: Built-in magnet, Port
Cylinder (Tube) Inner Diameter(φ): 25, Stroke(mm): 40, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Guided, Additional Function: Cylinder with functions of thrusting and boosting, Environment, Applications: Standard, Cushion: Rubber bumper at both ends, Operating Pressure(MPa): 0.05 to 0.7, Specification: Built-in magnet, Port
Cylinder (Tube) Inner Diameter(φ): 25, Stroke(mm): 50, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Guided, Additional Function: Cylinder with functions of thrusting and boosting, Environment, Applications: Standard, Cushion: Rubber bumper at both ends, Operating Pressure(MPa): 0.05 to 0.7, Specification: Built-in magnet, Port
Cylinder (Tube) Inner Diameter(φ): 25, Stroke(mm): 75, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Guided, Additional Function: Cylinder with functions of thrusting and boosting, Environment, Applications: Standard, Cushion: Rubber bumper at both ends, Operating Pressure(MPa): 0.05 to 0.7, Specification: Built-in magnet, Port
Cylinder (Tube) Inner Diameter(φ): 25, Stroke(mm): 10, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Guided, Additional Function: Cylinder with functions of thrusting and boosting, Environment, Applications: Standard, Cushion: Rubber bumper at both ends, Operating Pressure(MPa): 0.05 to 0.7, Specification: Built-in magnet, Port
Cylinder (Tube) Inner Diameter(φ): 25, Stroke(mm): 20, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Guided, Additional Function: Cylinder with functions of thrusting and boosting, Environment, Applications: Standard, Cushion: Rubber bumper at both ends, Operating Pressure(MPa): 0.05 to 0.7, Specification: Built-in magnet, Port
Cylinder (Tube) Inner Diameter(φ): 25, Stroke(mm): 30, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Guided, Additional Function: Cylinder with functions of thrusting and boosting, Environment, Applications: Standard, Cushion: Rubber bumper at both ends, Operating Pressure(MPa): 0.05 to 0.7, Specification: Built-in magnet, Port
Cylinder (Tube) Inner Diameter(φ): 25, Stroke(mm): 40, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Guided, Additional Function: Cylinder with functions of thrusting and boosting, Environment, Applications: Standard, Cushion: Rubber bumper at both ends, Operating Pressure(MPa): 0.05 to 0.7, Specification: Built-in magnet, Port
Cylinder (Tube) Inner Diameter(φ): 25, Stroke(mm): 50, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Guided, Additional Function: Cylinder with functions of thrusting and boosting, Environment, Applications: Standard, Cushion: Rubber bumper at both ends, Operating Pressure(MPa): 0.05 to 0.7, Specification: Built-in magnet, Port