SMC Corporation of America
Elite Part Number Search
Search Results "CXSM10-35-Y7P"

To use the lock for drop prevention purposes, the load to be attached to the cylinder must be within 35% of the cylinders holding force.

Applicable cylinder ML2B25 ML2B32 ML2B40 MY-S25A M6 x 1 35 50 8 5 9.5 5.5 B MY-S32A M8 x 1.25 45 64 11.7 6 11 6.6 B Guide for Side Support Application For long stroke operation, the cylinder tube may be deflected depending on its own weight and the load weight. In such a case, use a side support in the middle section.

Applicable cylinder ML2B25 ML2B32 ML2B40 MY-S25A M6 x 1 35 50 8 5 9.5 5.5 B MY-S32A M8 x 1.25 45 64 11.7 6 11 6.6 B Guide for Side Support Application For long stroke operation, the cylinder tube may be deflected depending on its own weight and the load weight. In such a case, use a side support in the middle section.

11 10 38 51 21 18 31 14 32 10 15 6.6 8.5 10.5 40 11 12 41 54 24 22 35 16 36 10 18 6.6 8.5 12 50 15 16 50 65 33 30 45 21 45 12 20 9 10.5 15 63 15 16 52 67 37 35 50 21 50 12 23 9 10.5 15 80 18 20 66 86 47 40 60 25 63 14 27 11 11.5 18 100 18 20 11 76 96 12.5 55 50 70 25 18 71 15 30 6-13-12 12 Series CP95 ISO/VDMA Cylinder: Standard Type Double Acting w/ End of Stroke Cushioning Dimensions:

S. 12. 16.. -) D-F59F With 2 pes (DJleren1 sunaces. 145 155 35 ~~~= m ~e~w= rt~'=~ ~).~ ~~'~~I~P' '--+-___ -cc-~_-+_ _~-;c-_~_-,=-~-_ D-F5NTL In 35+ 55 'n 2) 145 +55 ;4> 155+55 In2 4> 2 With n pes. (Same sunace) (n =2, 4. 6, S .. ) (I = 4 , 8, 12. 1 6'~"),--,-_ "-=,-4" '::J ~".-, ..,( ", = S. 12 ' =-6._) -1 R. Different surfaces 35 110 1 ~ ~N~_~s.

45 18 11 22 25 65 4.3 4 36 20 30 95 16 72 100 5 10 55 18 11 22 41 20 32 115 25 75 6.3 16 89 4 Mounting style (ES) Bore size (mm) d3 CN S5 K1 K2 I2 G1 G2 G3 EN EU CH H6 ER 32 11 10 38 51 21 18 31 14 32 10 15 10.5 8.5 6.6 40 11 12 41 54 24 22 35 16 36 10 18 12 8.5 6.6 50 15 16 50 65 33 30 45 21 45 12 20 15 10.5 9 63 15 16 52 67 37 35 50 21 50 12 23 15 10.5 9 80 18 20 66 86 47 40 60 25 63 14

Oil resistant flexible cabtire cord is used for D-Y59 , Y69 , Y7P(V) as standard. No need to suffix -61 to the end of part number. Note) A B A B Specifications are the same as standard products with the exception of lead wire specifications.

A CL Extension locking Retraction locking 40 to 100 Bore size (mm) A CL1 Drop prevention for press fitting jig Drop prevention for lifter Flat head screwdriver 20 25 32 40 50 63 80 100 26.5 30.5 31.5 34 35 38 43 51.5 MLGC CNG LOCK MNB Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

A CL Extension locking Retraction locking 40 to 100 Bore size (mm) A CL1 Drop prevention for press fitting jig Drop prevention for lifter Flat head screwdriver 20 25 32 40 50 63 80 100 26.5 30.5 31.5 34 35 38 43 51.5 MLGC CNG LOCK MNB 20 to 32 CNA Body length Manual unlocking bolt CNS LOCK Body length is the same as the standard MGP CLS Holding a clamped condition CLQ Locking direction is

wire length (m) * Auto switch model Indicator light Type Electrical entry Wiring (output) Electrical entry direction Special function Applicable load 0.5 (Nil) 3 (L) 5 (Z) AC DC Perpendicular In-line IC circuit IC circuit 3-wire (NPN equiv) Z76 5V Reed switch Yes Grommet 100V 12V Z73 Relay, PLC 24V 2-wire No 100V or less 5V, 12V Z80 3-wire (NPN) Y69A Y59A IC circuit 5V, 12V RE A B Y7PV Y7P

wire length (m) * Auto switch model Indicator light Type Electrical entry Wiring (output) Electrical entry direction Special function Applicable load 0.5 (Nil) 3 (L) 5 (Z) AC DC Perpendicular In-line IC circuit IC circuit 3-wire (NPN equiv) Z76 5V Reed switch Yes Grommet 100V 12V Z73 Relay, PLC 24V 2-wire No 100V or less 5V, 12V Z80 3-wire (NPN) Y69A Y59A IC circuit 5V, 12V RE A B Y7PV Y7P

Electrical entry Wiring (output) Special functions 0.5 (Nil) 3 (L) 5 (Z) Applicable load Indicator light Type Electrical entry direction DC AC Vertical Horizontal IC circuit Z76 3 wire 5V Grommet Yes Reed switch Z73 24V 12V 100V Relay PLC 2 wire 5V 12V 100V or less IC circuit Z80 No 3 wire (NPN) IC circuit 3 wire (PNP) Y7PV Y7P Y59A Y69A 5V 12V IC circuit Lead wire indicator symbol

MY CY Proper Auto Switch Mounting Position MG Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com A B Auto switch model CX D-Y5 D-Y6 D-Y7P D-Y7PV D-Y5 D-Y6 D-Y7P D-Y7PV D-Z7 D-Z80 D-Y7W D-Y7WV D-Y7W D-Y7WV D-Z7 D-Z80 DCylinder model CYP15 93.5 24.5 -X CYP32 122 33 20Data

9 @1 CXSM10 CXSM15 @0 @1 !9 @0 @1 !9 CXSM20 to 32 @0 @1 !9 The numbers are the same as the "Construction" of the Best Pneumatics No.3 Series CXS. *BLUE links will lead to purchase pages. Replacement Parts: Seal Kit Kit no. Contents Bore size (mm) Seal Kit List Description Material Note No. CXSM6-PS 6 10 15 20 25 32 CXSM 6-PS CXSM 10 A PS CXSM 15-PS CXSM 20-PS CXSM 25-PS CXSM 32-PS !

Dual rod cylinder with air cushion, Slide bearing or ball bushing bearing, Bore sizes: 20mm, 25mm, 32mm, Standard strokes: 20-100mm, Thread types: M, Rc, NPT, G, Auto switches available, FRONT MOUNTING PLATE (CXSM10), ACTUATOR, CXS GUIDED CYLINDER, E1, 10MM CXS PART, .03001 lb, SeriesDescriptionModelTypeNoteVol. no.

This explanation is based on the “Construction” section of the CXSM10 to 32 in the operation manual.
Loosen and remove the hexagon socket head set screw ⑬ and the hexagon socket head cap screw ⑫ holding the plate ⑤ and rods ② and ③, and then pull the plate out from the rod. Loctite is applied to the screws, so it may be difficult to remove them.

Mounting bolt Mounting bolt Spring Return Spring Extend Model C Mounting bolt Model C Mounting bolt D 25 30 25 30 25 30 30 35 30 35 35 40 45 55 D 25 30 25 30 25 30 30 35 30 35 35 40 45 55 CQ2B12-5S -10S CQ2B16-5S -10S CQ2B20-5S -10S CQ2B25-5S -10S CQ2B32-5S -10S CQ2B40-5S -10S CQ2B50-10S -20S CQ2B12-5T -10T CQ2B16-5T -10T CQ2B20-5T -10T CQ2B25-5T -10T CQ2B32-5T -10T CQ2B40-5T -10T CQ2B50-

60 70 70 80 ZZ 121 121 121 131 146 185 238 292 344 M 83 83 83 93 108 147 200 254 306 Z 81.5 81.5 81.5 91.5 106.5 145.5 198.5 252.5 304.5 K 31 41 51 61 71 96 121 146 171 J 44 44 44 54 69 108 113 155 190 I 10 10 10 10 10 10 58 70 87 NA 2 2 2 2 2 2 4 4 4 NN 2 2 2 2 3 4 5 6 7 KA 169 223 275 H 45 45 45 55 35 35 35 38 44 HA 35 35 35 35 35 70 70 76 88 G 15 15 15 15 15 19 37 41 19 GA 25 25 25 35

Standard Strokes Bore sizes (mm) Standard strokes (mm) 20, 25 5, 10, 15, 20, 25, 30, 35, 40, 45, 50 32 5, 10, 15, 20, 25, 30, 35, 40, 45, 50, 75 40, 50, 63, 80, 100 5, 10, 15, 20, 25, 30, 35, 40, 45, 50, 75, 100 Made to Order Hydraulic Fluid Compatibility Manufacture of Intermediate Stroke Cylinders Pages 10 to 12 Intermediate strokes in 5mm increments can be manufactured by installing spacers