r1m) 2, :ZZi 125 15 27 65 M30 x 1.5 30.5 11 2 98 35 40 45 29 110 273 302 75 40 133 lJ5 stroke 298 325 140 15 27 75 M30x 1.5 30,S 1 12 98 32 110 283 31So 75 40 ~33 .I stroke 3
MM Relief port FX 20, 25 Eh8 D FZ I 20 to 32 Standard port Relief port Width across flats NA 4-FD 45 1.5 AL 32, 40 A F N K N S + Stroke FT H FY Z + Stroke ZZ + Stroke 40 (mm) 4 7 FD E 20-0.033 0 52 40 40 34 B FX FZ FY G FT 13 8 AL D K MM NA NN B1 B2 Bore size ZZ Z H H2 H1 S P N I F C2 A 66 60 60 60 75 75 75 11 8 8 8 40 32 25 20 24 22 22 18 50 45 45 41 8 8 8 6 6 5 22 17 17 13 41 32 32 26
Extension end 8 10, 20, 30, 40, 50, 75 Rubber stopper Retraction end Both ends 12 10, 20, 30, 40, 50, 75, 100 16 10, 20, 30, 40, 50, 75, 100, 125 20 10, 20, 30, 40, 50, 75, 100, 125, 150 25 10, 20, 30, 40, 50, 75, 100, 125, 150 Functional option Standard type Nil PNote 1) Axial piping type Note 1) The combination of axial piping type and both ends adjusters or retraction end adjusteris not
133 406 Up to 1400 98 298 383 393 433 507 532 406 416 454 525 550 M30 x 1.5 8 9 0.2 stroke 184 98 393 30 to 1400 75 133 416 98 298 Up to 1400 M30 x 1.5 0.2 stroke 204 106 433 75 141 454 106 338 30 to 1400 Up to 1400 M36 x 1.5 25 31 41 0.2 stroke 228 111 503 85 153 521 115 402 30 to 1800 Up to 1500 M40 x 1.5 M12 x 1.75 0.2 stroke 257 111 523 90 153 541 120 427 30 to 1800 Up to 998 M45
55 75 80 90 75 + 35 (n 2) (n = 2, 4, 6, 8, ) Note 1) 80 + 35 (n 2) (n = 2, 4, 6, 8, ) Note 1) 90 + 35 (n 2) (n = 2, 4, 6, 8, ) Note 1) 20 + 35 (n 2) (n = 2, 3, 4, ) (Different surfaces) D-A44C n 75 + 50 (n 2) (n = 2, 4, 6, 8, ) Note 1) 80 + 50 (n 2) (n = 2, 4, 6, 8, ) Note 1) 90 + 50 (n 2) (n = 2, 4, 6, 8, ) Note 1) 55 + 50 (n 2) (n = 2, 3, 4, ) (Same surface) 1 10 75 80 90 2 (Different
(same side) D-Y59A (B), Y69A (B) Y7P (V) 20 1 pc., 2 pcs. (different sides) 70 2 pcs. (same side) D-Y7NW (V), Y7PW (V) Solid state switch Y7BW (V) 1 pc., 2 pcs. (different sides) 25 2 pcs. (same side) 70 D-Y7BAL 1pc., 2 pcs.
Wide Opening Air Gripper Series MHL2 Parallel Style/10, 16, 25, 20, 32, 40 How to Order D 16 MHL 2 1 Y59A S Wide opening Number of auto switches 2 1 n S 2 fingers 2 Numbers of fingers n Bore size 10mm 16mm 20mm 25mm 32mm 40mm 10 16 20 25 32 40 Auto switch Without auto switch (Built-in magnet) Auto switch specifications Action Load voltage Auto switch model no.
Standard Strokes [mm] Bore size [mm] Standard stroke [mm] 40 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500 50, 63 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500, 600 80, 100 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500, 600, 700 Note) Intermediate strokes not listed above are produced upon receipt of order.
, 100 64 53.5 10 to 50 63.5 17.5 depth 13.5 80 73.5 63.5 21 25 98 12.5 M16 x 2.0 132 6 22 10 77 11 3/8 16 112.5 57.5 26 63.5 75, 100 73.5 63 10 to 50 75 17.5 depth 13.5 100 85 73 27 30 117 13 M20 x 2.5 156 6.5 27 12 94 11 3/8 23 132.5 67.5 26 73 75, 100 85 10-4-8 9 Smooth Cylinder Series CM2Y 20, 25, 32, 40 Specifications and auto switch information not provided below are the same as those
, 100 64 53.5 10 to 50 63.5 17.5 depth 13.5 80 73.5 63.5 21 25 98 12.5 M16 x 2.0 132 6 22 10 77 11 3/8 16 112.5 57.5 26 63.5 75, 100 73.5 63 10 to 50 75 17.5 depth 13.5 100 85 73 27 30 117 13 M20 x 2.5 156 6.5 27 12 94 11 3/8 23 132.5 67.5 26 73 75, 100 85 10-4-8 9 Smooth Cylinder Series CM2Y 20, 25, 32, 40 Specifications and auto switch information not provided below are the same as those
, 100,125,150, 25, 50, 75, 100, 125,150,200 Relief type Vacuum suction type 1/8 10-/21-CG1RN32 10-/21-CG1RN40 32 40 25, 50, 75, 100, 125,150,200 250,300 50 63 20 25 32 40 50 63 10-/21-CG1RN50 10-/21-CG1RN63 11-/22-CG1RN20 11-/22-CG1RN25 11-/22-CG1RN32 11-/22-CG1RN40 11-/22-CG1RN50 11-/22-CG1RN63 1/4 Non-lube Double acting Not available 25, 50, 75, 100,125,150, Single rod 25, 50, 75, 100
, 100, 125, 150, 175, 200, 250, 300, 350 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350 50, 75, 100, 125, 150, 175, 200, 250, 300, 350 RLQ Manufacture of Intermediate Stroke MLU ML1C Spacer installation type Spacers are installed in the standard stroke cylinders. 20 to 32: Stroke can be modified by the 1 mm interval. 40 to 100: Stroke can be modified by the 5 mm interval.
, 100, 125, 150, 175, 200, 250, 300, 350 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350 50, 75, 100, 125, 150, 175, 200, 250, 300, 350 RLQ Manufacture of Intermediate Stroke MLU ML1C Spacer installation type Spacers are installed in the standard stroke cylinders. 20 to 32: Stroke can be modified by the 1 mm interval. 40 to 100: Stroke can be modified by the 5 mm interval.
Auto switch model Lead wire length (m) Load voltage Indicator light Special function Type Electrical entry Wiring (Output) Pre-wire connector Applicable load 0.5 (Nil) 3 (L) 5 (Z) Tie-rod mounting Band mounting AC DC 3-wire (NPN equivalent) IC circuit Z76 5 V Grommet Z73 A54 A59W Y59A Y7P J51 Y59B Y7NW Y7PW Y7BW Y7BA F59F A33 A34 A44 G39 K39 100 V Reed switch Solid state switch Relay,
Bore size (mm) Bore size (mm) DL DM HR LL MO DB Over 25 to 75st 98 Over 75 to 175st 118 Over 25 to 75st 13.5 Over 75 to 175st 33.5 Over 175st 25st or less 25st or less Over 175st 22 22 9.5 21 15 15 84.5 140 16 0 55.5 32 32 26 23 11.5 25.5 21 19 91 98 118 140 16 0 7 27 49 40 40 24 23 13 27 21 19 50 97 114 134 161 20 0 17 37 64 50 25 25.5 11 25 21 19 63 102 114 134 161 20 0 12 32 59 63
0.8 up to 90 0.7 Angle k 32 Angle coefficient (k) : k = [to 45 (= )] = 1, [to 60] = 0.9, [to 75] = 0.8, [to 90] = 0.7 Lo: Distance from mounting surface to load center of gravity (cm) 40 6 10 15 20 Bore size (mm) 2.72 1.6 + Lo 5.55 1.95 + Lo 15.96 2.4 + Lo 41.7 2.8 + Lo Allowable drive resisting force (FA) (kg) 5.
Y69A Y7PV Y69B Y7NWV Y7PWV Y7BWV 100 V 24 V 12 V Z73 Y59A Y7P Y59B Y7NW Y7PW Y7BW 3-wire (NPN) 2-wire Relay, PLC 5 V, 12 V IC circuit 3-wire (PNP) 2-wire 12 V Relay, PLC 24 V Grommet 3-wire (NPN) 3-wire (PNP) Diagnostic indication (2-color indication) IC circuit 5 V, 12 V 2-wire 12 V Lead wire length symbols: 0.5 mNil (Example) Y59A 3 m L (Example) Y59AL 5 m Z (Example) Y59AZ Since
Port size Lubrication Model Rubber Air 10-MGF40 10-MGF63 10-MGF100 1/8 Relief type (Both sides) Double acting 30, 50, 75, 100 1/4 Non-lube Non-standard intermediate strokes (in 5 mm increments) are available by attaching a spacer of 5, 10, 15, 20 or 25 mm width.
Y69A Y7PV Y69B Y7NWV Y7PWV Y7BWV 100 V 24 V 12 V Z73 Y59A Y7P Y59B Y7NW Y7PW Y7BW 3-wire (NPN) 2-wire Relay, PLC 5 V, 12 V IC circuit 3-wire (PNP) 2-wire 12 V Relay, PLC 24 V Grommet 3-wire (NPN) 3-wire (PNP) Diagnostic indication (2-color indication) IC circuit 5 V, 12 V 2-wire 12 V Lead wire length symbols: 0.5 mNil (Example) Y59A 3 m L (Example) Y59AL 5 m Z (Example) Y59AZ Since
Y7NWV IC circuit 5 V 12 V Diagnosis (2-color indication) Y7PW Y7PWV Y7BW Y7BWV 2-wire 12 V Water resistant (2-color indication) Y7BA Lead wire length symbols: 0.5 m Nil (Example) Y59A 3 m L (Example) Y59AL 5 m Z (Example) Y59AZ Refer to page 12-13-25 for solid state switch with pre-wire connector.