SMC Corporation of America
Elite Part Number Search
Search Results "CY1L25H-250B-F7BAL"

Bore size (mm) Auto switch models 20 32 to 100 D-F7/J79 D-F7V D-J79C D-F7W/J79W D-F7WV D-F7BAL/F7BAV D-F79F/F7NT D-A7/A80 D-A73C/A80C D-A7H/A80H D-A79W Note 4) Note 5) Refer to the table below for details on BBA2. When an additional D-M9A(V) is required, order stainless steel screw kit BBA2 or BQ2-012S as a set separately.

Note 50 63 32 40 Bore size (mm) Action Double acting Reed switch D-A7/A8 D-A73C/A80C D-A7H/A80H D-A79W Solid state switch D-F7/J79 D-F7V D-J79C D-F7W/J79W D-F7WV D-F7BAL/F78AVL D-F79F Fluid Air 0.1 to 0.6 MPa Operating pressure Switch mounting screw (M3 x 0.5 x 10l) Switch spacer Switch mounting nut. 5 to 60C Ambient and fluid temperature 32, 40 50, 63 BQ-2 Lubrication Not required 3 to

Note 50 63 32 40 Bore size (mm) Action Double acting Reed switch D-A7/A8 D-A73C/A80C D-A7H/A80H D-A79W Solid state switch D-F7/J79 D-F7V D-J79C D-F7W/J79W D-F7WV D-F7BAL/F78AVL D-F79F Fluid Air 0.1 to 0.6 MPa Operating pressure Switch mounting screw (M3 x 0.5 x 10l) Switch spacer Switch mounting nut. 5 to 60C Ambient and fluid temperature 32, 40 50, 63 BQ-2 Lubrication Not required 3 to

(Available for all the types. 3 meter type is standard for "D-F7BAL", "F79LF" and "F7NTL".) Possible to exchange basic style with flange style Specify with the part numbers shown below when ordering flange parts. Size 32 40 Part No.

With no external leakage, the CY series can be used in many diverse environments. Magnetically coupled cylinders have a wide range of applications, and save mounting space. Loads and moments are possible through the use of integrated guides. A variety of guides can be used to achieve the necessary accuracy or allowable moment needed for your application. CY is available in 9 bore sizes,

Bore Size: 25mm, Port Thread: Rc (or M Thread for 6 to 15 Bore), Magnetic Holding Force: L (Small Holding Force), Stroke: 250mm, Adjuster: B (Shock Absorbers (2 pcs)), Auto Switch: F7BA--Solid State, Water Resist., 2 Wire, Lead Wire, Horizontal, Lead Wire or Prewired Connector: L (3m)

Bore Size: 25mm, Port Thread: TN (NPT), Magnetic Holding Force: H (Large Holding Force), Stroke: 250mm, Adjuster: B (Shock Absorbers (2 pcs)), Auto Switch: F7BA--Solid State, Water Resist., 2 Wire, Lead Wire, Horizontal, Lead Wire or Prewired Connector: L (3m)

Bore Size: 25mm, Port Thread: TN (NPT), Magnetic Holding Force: L (Small Holding Force), Stroke: 250mm, Adjuster: B (Shock Absorbers (2 pcs)), Auto Switch: F7BA--Solid State, Water Resist., 2 Wire, Lead Wire, Horizontal, Lead Wire or Prewired Connector: L (3m)

Bore Size: 32mm, Port Thread: Rc (or M Thread for 6 to 15 Bore), Magnetic Holding Force: H (Large Holding Force), Stroke: 250mm, Adjuster: B (Shock Absorbers (2 pcs)), Auto Switch: F7BA--Solid State, Water Resist., 2 Wire, Lead Wire, Horizontal, Lead Wire or Prewired Connector: L (3m)

Bore Size: 25mm, Port Thread: Rc, Magnetic Holding Force: Large Holding Force, Stroke: 250mm, Adjuster: B [Shock Absorbers (2 pcs)], Auto Switch: F7BA--Solid State, Water Resist., 2 Wire, Lead Wire, Horizontal, Lead Wire or Prewired Connector: 3m, Number: -

Bore Size: 32mm, Port Thread: Rc, Magnetic Holding Force: Large Holding Force, Stroke: 250mm, Adjuster: B [Shock Absorbers (2 pcs)], Auto Switch: F7BA--Solid State, Water Resist., 2 Wire, Lead Wire, Horizontal, Lead Wire or Prewired Connector: 3m, Number: -

Type: Rodless Cylinder, Cylinder Inner Diameter(Ø): 32, Stroke(mm): 250, Max. Load Mass (Horizontal Mounting)(kg): 20~39.9, Table Size Length L(mm): 100, Table Material: [Aluminum] Aluminum Alloy, Rodless Cylinder Joint Type: Magnetic, Guide: [Rolling Guide] Ball bushing bearing, Table Size Width W(mm): 157, Table Size Height H(mm): 64, Table Surface Treatment: [Anodize] Alumite, Environment

Bore Size: 25mm, Port Thread: Rc (or M Thread for 6 to 15 Bore), Magnetic Holding Force: Small Holding Force, Stroke: 250mm, Adjuster: Shock Absorbers (2 pcs), Auto Switch: F7BA--Solid State, Water Resist., 2 Wire, Lead Wire, Horizontal, Lead Wire or Prewired Connector: 3m, Number: -

Bore Size: 25mm, Port Thread: NPT, Magnetic Holding Force: Large Holding Force, Stroke: 250mm, Adjuster: Shock Absorbers (2 pcs), Auto Switch: F7BA--Solid State, Water Resist., 2 Wire, Lead Wire, Horizontal, Lead Wire or Prewired Connector: 3m, Number: -

Bore Size: 25mm, Port Thread: NPT, Magnetic Holding Force: Small Holding Force, Stroke: 250mm, Adjuster: Shock Absorbers (2 pcs), Auto Switch: F7BA--Solid State, Water Resist., 2 Wire, Lead Wire, Horizontal, Lead Wire or Prewired Connector: 3m, Number: -

This is a legacy product. Please contact us for the latest version.sales@ocaire.com

This is a legacy product. Please contact us for the latest version.sales@ocaire.com

to 25 20 to 40 12 to 63 12 to 25 32 to 63 20 to 40 80/100 6 to 10 6 to 25 6 to 32 6 to 16 6 to 25 6 to 25 10/16 15/32 Bore size 610 6 D-C7/C8 D-C73C/C80C D-B5/B6 D-B59W D-A3/A4 D-A3A/A44A D-A3C/A44C D-A7/A8 D-A7H/A80H D-A73C/A80C D-A79W D-A5/A6 D-A59W D-A9 D-A9V D-Z7/Z8 D-H7 D-H7C D-H7BAL D-H7F D-H7W D-G5/K5 D-G5BAL D-G59F D-G5NTL D-G5W/K59W D-G39/K39 D-G39A/K39A D-F7/J7 D-J79C D-F7F D-F7BAL

CY MQQ M How to Order How to Order RHC Mounting -XC6 -XC6 Stroke Bore size CDA1 F5BAL R Type Mounting -XC6 -XC6 Stroke Bore size CDQ2 F7BAL D Option R Suffix MK(2) Made to order specifications Made to order specifications With auto switch (Built-in magnet) With auto switch (Built-in magnet) RS Q G Water resistant 2-color indication solid state switch Water resistant 2-color indication solid

to 25 20 to 40 12 to 63 12 to 25 32 to 63 20 to 40 80/100 6 to 10 6 to 25 6 to 32 6 to 16 6 to 25 6 to 25 10/16 15/32 Bore size 610 6 D-C7/C8 D-C73C/C80C D-B5/B6 D-B59W D-A3/A4 D-A3A/A44A D-A3C/A44C D-A7/A8 D-A7H/A80H D-A73C/A80C D-A79W D-A5/A6 D-A59W D-A9 D-A9V D-Z7/Z8 D-H7 D-H7C D-H7BAL D-H7F D-H7W D-G5/K5 D-G5BAL D-G59F D-G5NTL D-G5W/K59W D-G39/K39 D-G39A/K39A D-F7/J7 D-J79C D-F7F D-F7BAL