Since a large quantity of liquid will be pumped out, use a suitable throttle in the discharge port if problems occur. 17-5-163 24 Series PB Performance Curves: Built-in Solenoid Valve Type/Air Operated Type Cycle 1 Hz Cycle 5 Hz Cycle 10 Hz 70 70 70 60 60 60 Total lifting range (m) Total lifting range (m) Total lifting range (m) 50 50 50 40 40 40 SUP = 0.7 MPa SUP = 0.7 MPa SUP = 0.7 MPa
Quality grade (3) as system Odor Application (2) Oil mist (1) density No.1 Solid Moisture No.1 Labor-saving equipment Jigs and tools General cleaning (Air blow gun) 5 m others 2, 10 20, 40 70, 100 Air Filter Series AF Series AF Traces of dust, moisture and oil can be tolerated 5 mg/m3 (ANR) Humidity 100% Oil odor Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco,
Construction ARP20(K)/30(K)/40(K) ARP20K/30K/40K (With backflow function) r q 1 I N e A 2 OUT A IN OUT t BLEED A-A w y Note Component Parts Material No.
Series Construction ARP20(K)/30(K)/40(K) ARP20K/30K/40K (With backflow function) r q 1 I N e A 2 OUT A IN OUT t BLEED A-A w y Note Component Parts Material No.
Cooling Method: A (Air-cooled Refrigeration), Pipe Thread: F [G (w/Rc-G Conversion Fitting)], Power Supply: 40 [3-phase 380 to 415 VAC (50/60 Hz)]
Cooling Capacity: 100 (10 kW), Cooling Method: A (Air-cooled), Pipe Thread: F (G, w/Rc-G Conversion Fitting), Power Supply: 40 [3-phase 380 to 415 VAC (50/60 Hz)]
Cooling Capacity: 150 (15 kW), Cooling Method: A (Air-cooled), Pipe Thread: F (G, w/Rc-G Conversion Fitting), Power Supply: 40 [3-phase 380 to 415 VAC (50/60 Hz)]
Cooling Method: Air-cooled Refrigeration, Pipe Thread: G, w/Rc-G Conversion Fitting, Power Supply: 3-phase 380 to 415 VAC, 50/60 Hz; 3-phase 460 to 480 VAC (60 Hz), Option: -
Cooling Method: Air-cooled Refrigeration, Pipe Thread: F [G (w/Rc-G Conversion Fitting)], Power Supply: 40 [3-phase 380 to 415 VAC (50/60 Hz)], Option: -
Cooling Capacity: 10 kW, Cooling Method: Air-cooled, Pipe Thread: G, w/Rc-G Conversion Fitting, Power Supply: 40 [3-phase 380 to 415 VAC (50/60 Hz)], Option: -
Cooling Capacity: 15 kW, Cooling Method: Air-cooled, Pipe Thread: G, w/Rc-G Conversion Fitting, Power Supply: 40 [3-phase 380 to 415 VAC (50/60 Hz)], Option: -
Cooling Capacity: 28 kW, Thread: G, w/Rc-G Conversion Fitting, Option: -
Cooling Capacity: 25kW, Thread: G, w/Rc-G Conversion Fitting, Option: -
Cooling Capacity: 15.7kW, Thread: G, w/Rc-G Conversion Fitting, Option: -
Cooling Capacity: 20.5kW, Thread: G, w/Rc-G Conversion Fitting, Option: -
Cooling Capacity: CH1: 19 kW; CH2: 1 kW, Pipe Thread: F [G (Rc-G Thread Adapter Set is Included)], Power Supply: 40 [3-phase 380 to 415 VAC (50/60 Hz); 3-phase 460 to 480 VAC (60 Hz)], DI Option: -, Pump Option: -
Cooling Capacity: CH1: 9 kW; CH2: 1 kW, Pipe Thread: F [G (Rc-G Thread Adapter Set is Included)], Power Supply: 40 [3-phase 380 to 415 VAC (50/60 Hz); 3-phase 460 to 480 VAC (60 Hz)], DI Option: -, Pump Option: -
Cooling Capacity: 200 (CH1: 19 kW; CH2: 1 kW), Pipe Thread: F [G (Rc-G Thread Adapter Set is Included)], Power Supply: 40 [3-phase 380 to 415 VAC (50/60 Hz); 3-phase 460 to 480 VAC (60 Hz)]
Cooling Capacity: 100 (CH1: 9 kW; CH2: 1 kW), Pipe Thread: F [G (Rc-G Thread Adapter Set is Included)], Power Supply: 40 [3-phase 380 to 415 VAC (50/60 Hz); 3-phase 460 to 480 VAC (60 Hz)]
Cooling Capacity: 300 (28 kW), Thread: F (G, w/Rc-G Conversion Fitting)