Rated Distance Range: 0.02 to 0.15mm, Piping Specifications: Supply Side: G 1/8, Detection Side: G 1/8, Output Specifications: PNP Output, Unit Specification: w/Unit Conversion Function, Stations: 6, Cable Option: Centralized Lead Wire, Lead Wire Only, Bracket Option: -, Control Unit: -, 2 Port Solenoid Valve Rated Voltage: -
Rated Distance Range: 0.02 to 0.15mm, Piping Specifications: Supply Side: G 1/8, Detection Side: G 1/8, Output Specifications: PNP Output, Unit Specification: w/Unit Conversion Function, Stations: 1, Cable Option: Right Angle, Bracket Option: -, Control Unit: -, 2 Port Solenoid Valve Rated Voltage: -
Rated Distance Range: 0.02 to 0.15mm, Piping Specifications: Supply Side: G 1/8, Detection Side: G 1/8, Output Specifications: PNP Output, Unit Specification: w/Unit Conversion Function, Stations: 3, Cable Option: None, Bracket Option: Bracket, Control Unit: -, 2 Port Solenoid Valve Rated Voltage: -
Rated Distance Range: 0.02 to 0.15mm, Piping Specifications: Supply Side: G 1/8, Detection Side: G 1/8, Output Specifications: PNP Output, Unit Specification: Fixed SI Unit, Stations: 2, Cable Option: -, Bracket Option: -, Control Unit: -, 2 Port Solenoid Valve Rated Voltage: -
Rated Distance Range: 0.02 to 0.15mm, Piping Specifications: Supply Side: G 1/8, Detection Side: G 1/8, Output Specifications: PNP Output, Unit Specification: w/Unit Conversion Function, Stations: 2, Cable Option: -, Bracket Option: -, Control Unit: -, 2 Port Solenoid Valve Rated Voltage: -
Rated Distance Range: 0.02 to 0.15mm, Piping Specifications: Supply Side: G 1/8, Detection Side: G 1/8, Output Specifications: PNP Output, Unit Specification: w/Unit Conversion Function, Stations: 2, Cable Option: Centralized Lead Wire, Lead Wire Only, Bracket Option: -, Control Unit: -, 2 Port Solenoid Valve Rated Voltage: -
Rated Distance Range: 0.02 to 0.15mm, Piping Specifications: Supply Side: G 1/8, Detection Side: G 1/8, Output Specifications: PNP Output, Unit Specification: w/Unit Conversion Function, Stations: 4, Cable Option: Centralized Lead Wire, Lead Wire Only, Bracket Option: -, Control Unit: -, 2 Port Solenoid Valve Rated Voltage: -
Rated Distance Range: 0.02 to 0.15mm, Piping Specifications: Supply Side: G 1/8, Detection Side: G 1/8, Output Specifications: PNP Output, Unit Specification: w/Unit Conversion Function, Stations: 3, Cable Option: None, Bracket Option: -, Control Unit: -, 2 Port Solenoid Valve Rated Voltage: -
Rated Distance Range: 0.02 to 0.15mm, Piping Specifications: Supply Side: G 1/8, Detection Side: G 1/8, Output Specifications: PNP Output, Unit Specification: w/Unit Conversion Function, Stations: 6, Cable Option: None, Bracket Option: -, Control Unit: -, 2 Port Solenoid Valve Rated Voltage: -
Rated Distance Range: 0.02 to 0.15mm, Piping Specifications: Supply Side: G 1/8, Detection Side: G 1/8, Output Specifications: PNP Output, Unit Specification: w/Unit Conversion Function, Stations: 5, Cable Option: Centralized Lead Wire, Lead Wire Only, Bracket Option: -, Control Unit: -, 2 Port Solenoid Valve Rated Voltage: -
Number of stations: 1 station, Option: No bracket, Detection distance(mm): 0.02 to 0.15, Piping specifications: Supply side (G1/8), detection side (G1/8), Output specifications: PNP 1 output, Unit specification for pressure values: With unit switching function, Cable: Straight cable
Number of stations: 1 station, Option: With Bracket, Detection distance(mm): 0.02 to 0.15, Piping specifications: Supply side (G1/8), detection side (G1/8), Output specifications: PNP 1 output, Unit specification for pressure values: With unit switching function, Cable: Straight cable
Number of stations: 1 station, Option: No bracket, Detection distance(mm): 0.02 to 0.15, Piping specifications: Supply side (G1/8), detection side (G1/8), Output specifications: PNP 1 output, Unit specification for pressure values: With unit switching function, Cable: None
Number of stations: 1 station, Option: With Bracket, Detection distance(mm): 0.02 to 0.15, Piping specifications: Supply side (G1/8), detection side (G1/8), Output specifications: PNP 1 output, Unit specification for pressure values: With unit switching function, Cable: None
Number of stations: Triple, Option: With Bracket, Detection distance(mm): 0.02 to 0.15, Piping specifications: Supply side (G1/8), detection side (G1/8), Output specifications: PNP 1 output, Unit specification for pressure values: With unit switching function, Cable: Straight cable
Number of stations: 4 stations, Option: With Bracket, Detection distance(mm): 0.02 to 0.15, Piping specifications: Supply side (G1/8), detection side (G1/8), Output specifications: PNP 1 output, Unit specification for pressure values: With unit switching function, Cable: Straight cable
Number of stations: 1 station, Option: No bracket, Detection distance(mm): 0.02 to 0.15, Piping specifications: Supply side (G1/8), detection side (G1/8), Output specifications: PNP 1 output, Unit specification for pressure values: SI unit fixed, Cable: Straight cable
Number of stations: 2 stations, Option: With Bracket, Detection distance(mm): 0.02 to 0.15, Piping specifications: Supply side (G1/8), detection side (G1/8), Output specifications: PNP 1 output, Unit specification for pressure values: SI unit fixed, Cable: Straight cable
Air catch sensor, Operating pressure: 0.05 to 0.2MPa, Enclosure IP66, Port size: 1/8, Fluid: dry air, DIGITAL GAP CHECKER, AIR CATCH SENSOR, ISA ISA2 ISA3, 825, 706.00000 lb
Rated Distance Range: H (0.05 to 0.30mm), Piping Specifications: C (Supply Side: Rc 1/8, Detection Side: ø6 One-touch Fitting or ø4 One-touch Fitting in case of Rated Distance Range 0.01 to 0.03 mm), Output Specifications: N (NPN Output), Unit Specification: w/Unit Conversion Function, Stations: 2, Cable Option: N (None), Bracket Option: B (Bracket), Control Unit: R2 (w/Control Unit, Supply