Search Results "ISE10-M5R-C-GD"

Pressure Range: F (-100.0 to 100kPa), Piping Specifications: M5R (M5 Female Thread/Rear Piping Port), Output Specifications: C (NPN Open Collector 1 Output+Analog Voltage), Unit Specifications: P (Unit Switching Function, Initial Value psi, Not Allowed for Use in Japan), Lead Wire: G [Lead Wire w/Connector (2m Lead Wire Length)+Connector Cover]

Pressure Range: 0.0 to -101.0kPa, Piping Specifications: M5R (M5 Female Thread/Rear Piping Port), Output Specifications: C (NPN Open Collector 1 Output+Analog Voltage), Unit Specifications: P (Unit Switching Function, Initial Value psi, Not Allowed for Use in Japan), Lead Wire: G [Lead Wire w/Connector (2m Lead Wire Length)+Connector Cover]

Pressure Range: F (-100.0 to 100kPa), Piping Specifications: M5R (M5 Female Thread/Rear Piping Port), Output Specifications: C (NPN Open Collector 1 Output+Analog Voltage), Unit Specifications: M (Fixed SI Unit, kPa), Lead Wire: G [Lead Wire w/Connector (2m Lead Wire Length)+Connector Cover]

Pressure Range: F (-100.0 to 100kPa), Piping Specifications: M5R (M5 Female Thread/Rear Piping Port), Output Specifications: C (NPN Open Collector 1 Output+Analog Voltage), Unit Specifications: M (Fixed SI Unit, kPa), Lead Wire: G [Lead Wire w/Connector (2m Lead Wire Length)+Connector Cover], Adapter: D (Panel Mount Adapter+Front Protective Cover)

Pressure Range: 0.0 to -101.0kPa, Piping Specifications: M5R (M5 Female Thread/Rear Piping Port), Output Specifications: C (NPN Open Collector 1 Output+Analog Voltage), Unit Specifications: P (Unit Switching Function, Initial Value psi, Not Allowed for Use in Japan), Lead Wire: No Lead Wire, Adapter: D (Panel Mount Adapter+Front Protective Cover)

Pressure Range: F (-100.0 to 100kPa), Piping Specifications: M5R (M5 Female Thread/Rear Piping Port), Output Specifications: C (NPN Open Collector 1 Output+Analog Voltage), Unit Specifications: M (Fixed SI Unit, kPa), Lead Wire: G [Lead Wire w/Connector (2m Lead Wire Length)+Connector Cover], Adapter: D (Panel Mount Adapter+Front Protective Cover), Calibration Certificate: K (w/Certificate

Piping Specifications: M5 (M5 Female Thread/Side Piping Port), Output Specifications: A (NPN Open Collector 2 Outputs), Unit Specifications: Unit Switching Function (Not Allowed for Use in Japan), Lead Wire: G [Lead Wire w/Connector (2m Lead Wire Length)+Connector Cover], Adapter: D (Panel Mount Adapter+Front Protective Cover)

Piping Specifications: M5 (M5 Female Thread/Side Piping Port), Output Specifications: B (PNP Open Collector 2 Outputs), Unit Specifications: Unit Switching Function (Not Allowed for Use in Japan), Lead Wire: G [Lead Wire w/Connector (2m Lead Wire Length)+Connector Cover], Adapter: D (Panel Mount Adapter+Front Protective Cover)

Type: Pressure Switch, Fluid Type: Air, Sensor, Monitor Structure: [Integrated Type] Integrated shape, Analog Output Specification: -, Pipe Port Type: Female Thread, Plumbing Thread Type: M, Plumbing Thread Nominal: M5x0.8, Fluid Characteristics: Noncorrosive / Incombustible, Pressure Resistance(MPa): 1.5, Operating Temperature Range(°C): -5~50, Operating Humidity Range(%): 35~85, Number

Piping Specifications: M5 Female Thread/Side Piping Port, Output Specifications: NPN Open Collector 2 Outputs, Unit Specifications: Unit Switching Function (Not Allowed for Use in Japan), Lead Wire: G [Lead Wire w/Connector (2m Lead Wire Length)+Connector Cover], Adapter: Panel Mount Adapter+Front Protective Cover, Calibration Certification: -

ZSE10/ISE10 compact, digital pressure switch has been reduced in height by approximately 50% when compared to the I/ZSE30A.? Up to 10 slave sensors can be set at once using the copy settings function.? Options include?direct mount, panel mount?or DIN rail mount, and a choice of 2 piping directions.?

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, PRESSURE SWITCH, INSTRUMENTATION, ISE30/ISE30A PRESSURE SWITCH, AA, ISE30 M5 PT VERSION, 0.44092 lb

ZSE10/ISE10 compact, digital pressure switch has been reduced in height by approximately 50% when compared to the I/ZSE30A.? Up to 10 slave sensors can be set at once using the copy settings function.? Options include?direct mount, panel mount?or DIN rail mount, and a choice of 2 piping directions.?

2-Color Display High-Precision Digital Pressure Switch ZSE30A(F)/ISE30A Series RoHS ZSE20 ISE20 ZSE30 ISE30 ZSE30 ISE30 How to Order Output specifications ZSE40 ISE40 N P A B C D E F NPN open collector 1 output PNP open collector 1 output NPN open collector 2 outputs PNP open collector 2 outputs NPN open collector 1 output + Analog voltage output NPN open collector 1 output + Analog current

White 3 (FUNC) Gray 2 DC(-) Blue 1 Thank you for purchasing the SMC ZSE10(F)/ISE10 Series Digital Pressure Switch.

ZS-32-A Length: 2 m (With rubber cover) Note Lead wire with connector Mist separator regulator AWM20/AWM30/AWM40 For ISE35--A (AR/AW series) Mounting thread (M3 x 7L, 2 pcs.), adapter, lock pin, O-ring are attached ZS-32-C Mounting option Micro mist separator regulator AWD20/AWD30/AWD40 For ISE35--B (ARM10/11 series) Mounting thread (M3 x 13, 2 pcs.), adapter, lock pin, O-ring are attached

(5.1) 10 5.8 4 5.5 36 1 0.2 6.5 6.5 1 3 39 28 10.5 3.3 T-slot A +0.030 0 depth 4 +0.030 0 depth 4 C 4H9 L-M6 Refer to Cross section C-C.

GD (A) (mm) Dimensions Mass (kg) Applicable dryer IDF22E IDF37E IDU22E IDU37E IDU55E IDU75E Port size Rc 1 1 1/2 1 1 1/2 B C D A Part no.