Pressure Range: ISE70 (0 to 1 MPa), Piping: 02 (Rc 1/4), Output Specification: L2 (I/O Link: Switch Output 1 + Switch Output 2 [Switch Output: NPN or PNP Switching Type]), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: S (Lead Wire with M12 Connector; Straight, 5 m)
Pressure Range: ISE70 (0 to 1 MPa), Piping: 02 (Rc 1/4), Output Specification: L2 (I/O Link: Switch Output 1 + Switch Output 2 [Switch Output: NPN or PNP Switching Type]), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: L (Lead Wire with M12 Connector; Right-angled, 5 m)
Pressure Range: ISE70 (0 to 1 MPa), Piping: 02 (Rc 1/4), Output Specification: L2 (I/O Link: Switch Output 1 + Switch Output 2 [Switch Output: NPN or PNP Switching Type]), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: None, Bracket: None, Operation Manual/Calibration Certificate: Y (None)
Pressure Range: ISE70 (0 to 1 MPa), Piping: 02 (Rc 1/4), Output Specification: L2 (I/O Link: Switch Output 1 + Switch Output 2 [Switch Output: NPN or PNP Switching Type]), Unit Specification: M (SI Unit Only), Lead Wire: L (Lead Wire with M12 Connector; Right-angled, 5 m)
Pressure Range: ISE70 (0 to 1 MPa), Piping: 02 (Rc 1/4), Output Specification: L2 (I/O Link: Switch Output 1 + Switch Output 2 [Switch Output: NPN or PNP Switching Type]), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: S (Lead Wire with M12 Connector; Straight, 5 m), Bracket: B (Bracket B), Operation Manual/Calibration Certificate
Pressure Range: ISE70 (0 to 1 MPa), Piping: 02 (Rc 1/4), Output Specification: L2 (I/O Link: Switch Output 1 + Switch Output 2 [Switch Output: NPN or PNP Switching Type])
Pressure Range: ISE70 (0 to 1 MPa), Piping: 02 (Rc 1/4), Output Specification: L2 (I/O Link: Switch Output 1 + Switch Output 2 [Switch Output: NPN or PNP Switching Type]), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: None, Bracket: None, Operation Manual/Calibration Certificate: K (Operation Manual + Calibration Certificate
Pressure Range: ISE70 (0 to 1 MPa), Piping: 02 (Rc 1/4), Output Specification: L2 (I/O Link: Switch Output 1 + Switch Output 2 [Switch Output: NPN or PNP Switching Type]), Unit Specification: M (SI Unit Only), Lead Wire: None, Bracket: None, Operation Manual/Calibration Certificate: Y (None)
Pressure Range: ISE70 (0 to 1 MPa), Piping: 02 (Rc 1/4), Output Specification: L2 (I/O Link: Switch Output 1 + Switch Output 2 [Switch Output: NPN or PNP Switching Type]), Unit Specification: M (SI Unit Only), Lead Wire: L (Lead Wire with M12 Connector; Right-angled, 5 m), Bracket: None, Operation Manual/Calibration Certificate: Y (None)
Pressure Range: ISE71 (0 to 1.6 MPa), Piping: 02 (Rc 1/4), Output Specification: L2 (I/O Link: Switch Output 1 + Switch Output 2 [Switch Output: NPN or PNP Switching Type]), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: L (Lead Wire with M12 Connector; Right-angled, 5 m), Bracket: A (Bracket A, Interchangeable with ISE70)
Pressure Range: ISE70 (0 to 1 MPa), Piping: 02 (Rc 1/4), Output Specification: L2 (I/O Link: Switch Output 1 + Switch Output 2 [Switch Output: NPN or PNP Switching Type]), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: None, Bracket: B (Bracket B)
. ## Description 00 Set to the test operation mode. 01 Station number 1 02 Station number 2 03 Station number 3 : : : : 62 Station number 62 63 Station number 63 64 Station number 64 Note 2. $$$ indicates numbers from 0 to 255, and the number indicates the executing point table number. 3. indicates the warning/alarm No. 4. Requires set up software(MR Configurator2TM) . -11- 3.
. ## Description 00 Set to the test operation mode. 01 Station number 1 02 Station number 2 03 Station number 3 : : : : 62 Station number 62 63 Station number 63 64 Station number 64 Note 2. $$$ indicates numbers from 0 to 255, and the number indicates the executing point table number. 3. indicates the warning/alarm No. 4. Requires set up software(MR Configurator2TM) . -11- 3.
CG1 series GC GD W C port C port D port B port A port D port W H SB + Stroke SA + Stroke ZZ + 2 x Stroke CG1 (mm) CG1K (mm) Bore size GC GD H SA SB W ZZ Long stroke Note) SA ZZ 20 21 9 35 48 87 30 172 56 180 25 21 9 40 48 87 30 177 56 185 32 23 9 40 50 91 30 183 58 191 40 25 9 50 56 100 20 208 65 217 50 29 13 58 63 118 20 241 75 253 63 28 12 58 64 117 20 241 76 253 Bore size GC GD H SA SB
Allowable Moment (Nm) Allowable dynamic moment Allowable static moment Pitching Rolling Yawing 4 3 4 LXF Model Load movement direction a = 1000 2000 a Mep a = 2000 L1 (mm) Pitching Rolling Yawing a = 3000 m : Transfer load (kg) L : Overhang to work piece center of gravity (mm) a : Work piece acceleration (mm/sec) Me: Dynamic moment 1000 m L1 3 0 1 2 Transfer load m (kg) a = 1000 300 L2 (mm
MHL MHR Model/Stroke Opening/Closing stroke (mm) L2 L1 Weight (g) Max. operating frequency (c.p.m.)
Refer to page 83 for dimensions. 80 Accessories Series CP96/C96 Dimensions: Cylinder Mounting Accessories Single clevis (C) Double clevis (D) Series C85 Series CP96 Series C96 Series C55 l2 l2 CDH9 l1 l1 Bore size (mm) 32 40 50 63 80 100 125 l1 l2 E1 EW TG1 FL L d1 CD MR d2 R1 E2 UB CB 0.2 0.6 0.2 0.6 0.2 0.6 0.2 0.6 0.2 0.6 0.2 0.6 0.5 1.2 45 26 32.5 22 5 12 5.5 30 10 9.5 6.6 6.5 48 45
m (kg) 1000 a = 1000 to 3000 L2 500 Mer m 5 10 0 Transfer load m (kg) a 1000 Mey a = 1000 to 3000 500 m L3 5 10 0 Transfer load m (kg) Refer to page 304 for deflection data. 268 5 Phase Stepper Motor/Without Motor Brake Series LXS Dimensions/LXSH5BD Scale: 25% F G x I +0.030 0 depth 5 +0.030 0 depth 5 5H9 D-5.1 through Refer to Cross section C-C, bottom view.
SA VA SA Selection Caution One-touch Fitting VA Operation method: The valve must be switched to OPEN or SHUT instantly and securely. Stopping the handle halfway between the extreme positions may cause malfunction. 1.