SMC Corporation of America
Elite Part Number Search
Search Results "ISE70-N02-L2-T"

Series VT Not Available In The USA BACKGROUND Many current pneumatic solenoid valves are a c t u a l l y o f s o l e n o i d p i l o t c o n s t r u c t i o n . T h e s o l e n o i d d o e s n o t o p e r a t e d i r e c t l y u p o n t h e s p o o l o r p o p p e t w i t h i n t h e v a l v e . W h a t t h e solenoid does is open a very small pilot valve.

/ISE75(H) ISE70/ISE75(H) ISE70/ISE75(H) ISE70/ISE75(H) () 1 ON ON OFF Yes No 2 OFF ON 1 OFF 3 4 5 -26No.PS-OMH0002CN-D 6 Yes No 7 7 8 9 10 11 12 13 14 15 -27No.PS-OMH0002CN-D No.

L1 (Extension nozzle length) Width across flats 14 R1/4 D L L2 H1 Outside diameter 4 Series VMG Dimensios: Nozzle Cover Cover for male thread nozzle [mm] Nozzle cover part no.

Bracket A Bracket B [F 0] Display units, switch output specifications and diagnostic information selection function ISE70(G): 0.500 MPa/ISE71: 0.800 MPa/ ISE75G: 1.000 MPa/ISE76G: 2.50 MPa/ ISE77G: 5.00 MPa/ISE78G: 8.00 MPa Pressure setting Cross recessed round head screw: Nominal size M4 x 6L Cross recessed round head screw: Nominal size M4 x 6L Item Default setting ISE70(G): 0.050 MPa/ISE71

Piping specification: -02 and -N02 After hand tightening, tighten the fitting using a spanner on the flat surfaces of the fitting. The tightening torque must be 8 to 12 Nm.

Pressure Range: ISE70 (0 to 1 MPa), Piping: N02 (NPT 1/4), Output Specification: AB (Switch Output 1 + Switch Output 2 [NPN or PNP Switching Type]), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: None, Bracket: A (Bracket A, Interchangeable with ISE70)

Pressure Range: ISE70 (0 to 1 MPa), Piping: N02 (NPT 1/4), Output Specification: AB (Switch Output 1 + Switch Output 2 [NPN or PNP Switching Type]), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: S (Lead Wire with M12 Connector; Straight, 5 m), Bracket: A (Bracket A, Interchangeable with ISE70)

Pressure Range: ISE70 (0 to 1 MPa), Piping: N02 (NPT 1/4), Output Specification: AB (Switch Output 1 + Switch Output 2 [NPN or PNP Switching Type]), Unit Specification: M (SI Unit Only), Lead Wire: L (Lead Wire with M12 Connector; Right-angled, 5 m), Bracket: A (Bracket A, Interchangeable with ISE70), Operation Manual/Calibration Certificate: K (Operation Manual + Calibration Certificate)

Pressure Range: ISE70 (0 to 1 MPa), Piping: N02 (NPT 1/4), Output Specification: AB (Switch Output 1 + Switch Output 2 [NPN or PNP Switching Type]), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: L (Lead Wire with M12 Connector; Right-angled, 5 m), Bracket: A (Bracket A, Interchangeable with ISE70), Operation Manual/Calibration

Pressure Range: ISE70 (0 to 1 MPa), Piping: N02 (NPT 1/4), Output Specification: AB (Switch Output 1 + Switch Output 2 [NPN or PNP Switching Type]), Unit Specification: M (SI Unit Only), Lead Wire: S (Lead Wire with M12 Connector; Straight, 5 m), Bracket: A (Bracket A, Interchangeable with ISE70), Operation Manual/Calibration Certificate: Y (None)

Pressure Range: ISE70 (0 to 1 MPa), Piping: N02 (NPT 1/4), Output Specification: AB (Switch Output 1 + Switch Output 2 [NPN or PNP Switching Type]), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: None, Bracket: A (Bracket A, Interchangeable with ISE70), Operation Manual/Calibration Certificate: Y (None)

Pressure Range: ISE70 (0 to 1 MPa), Piping: N02 (NPT 1/4), Output Specification: AB (Switch Output 1 + Switch Output 2 [NPN or PNP Switching Type]), Unit Specification: M (SI Unit Only), Lead Wire: None, Bracket: A (Bracket A, Interchangeable with ISE70), Operation Manual/Calibration Certificate: Y (None)

Pressure Range: ISE70 (0 to 1 MPa), Piping: N02 (NPT 1/4), Output Specification: AB (Switch Output 1 + Switch Output 2 [NPN or PNP Switching Type]), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: L (Lead Wire with M12 Connector; Right-angled, 5 m), Bracket: A (Bracket A, Interchangeable with ISE70)

Pressure Range: ISE70 (0 to 1 MPa), Piping: N02 (NPT 1/4), Output Specification: AB (Switch Output 1 + Switch Output 2 [NPN or PNP Switching Type]), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: L (Lead Wire with M12 Connector; Right-angled, 5 m), Bracket: A (Bracket A, Interchangeable with ISE70), Operation Manual/Calibration

4 24 17 28.6 70.3 61.8 ASP630F-04-12S-X369 12 21.7 35.2 49.5 25 21.8 ASP330F-N01-07S-X369 NPT1/8 10-32UNF 12 8 14.2 23.9 31 13.6 38.6 35.2 16.8 1/4 13.2 ASP430F-N02-07S-X369 25.2 34.4 18.3 16.8 ASP430F-N02-09S-X369 5/16 15.2 27.2 36.4 18.4 18.7 17.46 12.7 18.5 48.7 42.4 NPT1/4 ASP430F-N02-11S-X369 3/8 18.5 35.3 44.5 19 20.8 NPT1/8 ASP530F-N03-09S-X369 5/16 15.2 29.7 41.2 18.7 NPT3/8 19 12

Description No. 2 Common IN Individual IN Common IN Individual IN Bonnet Polyacetal Regulator NARM2500-A-N02 NARM2500-B-N02 NARM3000-A-N03 NARM3000-B-N03 9 Regulator 1 Component Parts 10 End plate R 1 No.

Type: Pressure Switch, Fluid Type: Air, Maximum Pressure Rating: 1MPa, Minimum Pressure Rating: 0kPa, Sensor, Monitor Structure: [Integrated Type] Integrated shape, Output Method: Switch, Pipe Port Type: [Threads] Male thread, Plumbing Thread Type: [NPT] NPT, Plumbing Thread Nominal: [1/4] 1/4, Fluid Characteristics: Noncorrosive / Incombustible, Pressure Resistance(MPa): 1.5, Operating Humidity

Description Material 1 Body SCS14A (SUS 316) 2 Needle SUS316 L4 3 Lock nut SUS316 4 Valve SUS316 5 Valve guide SUS316, NBR for low temperature L2 L3 6 Spring SUS316 7 Bolt SUS316 8 O-ring NBR for low temperature L5 9 O-ring NBR for low temperature Model Port size D H L1 L2 L3 L4 Note) L5 Mass g MAX. MIN.

Pressure Range: ISE70 (0 to 1 MPa), Piping: N02 (NPT 1/4), Output Specification: AB (Switch Output 1 + Switch Output 2 [NPN or PNP Switching Type])

Pressure Range: ISE70 (0 to 1 MPa), Piping: N02 (NPT 1/4), Output Specification: AB (Switch Output 1 + Switch Output 2 [NPN or PNP Switching Type]), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: S (Lead Wire with M12 Connector; Straight, 5 m)