SMC Corporation of America
Elite Part Number Search
Search Results "KM11-03-09-10"

) 04 T-interface Note 6) Note 7) Y110-M5 VHS20-01 02 VHS50-06 10 3-port valve for residual pressure release Note 7) VHS30-02 03 VHS40-06 01 E200-02 03 02 E300-03 04 E600-06 10 Piping adapter Note 7) E500-06 E100-M5 01 IS1000E-2002 03 02 IS1000E-3003 04 Pressure switch with piping adapter Note 7) Y24-01 02 Y34-01 02 Y54-03 04 Cross spacer Note 7) Y14-M5 Note 1) in part numbers for a round

Width across flat Effective area (mm2) Connection thread Rc Weight (g) L1 L2 M d Model H1 H2 H2 H1 I.D. 2.5 3 4 6 7.5 8 9 10 13 4 4 6 8 10 10 12 12 16 KFG2F0425-02 KFG2F0403-02 KFG2F0604-02 KFG2F0806-03 KFG2F1075-03 KFG2F1008-03 KFG2F1209-03 KFG2F1210-03 KFG2F1613-04 1.6 2.6 6 17 30 35 45 57 101 1/4 1/4 1/4 3/8 3/8 3/8 3/8 3/8 1/2 1.8 2.3 3.3 5.3 6.8 7.3 8 9 12 d 17 8 25.9 16.4 5 24 17 19

0040 0001 BB [CR][LF] :01 03 02 09E1 10 [CR][LF] Answer 25.29 deg.C. 0041 Reading external Sensor temperature 1 :01 03 0041 0001 BA [CR][LF] :01 03 02 09E1 10 [CR][LF] Answer 25.29 deg.C. 0043 Reading status 1 :01 03 0043 0001 B8 [CR][LF] :01 03 02 0005 F5 [CR][LF] Run with alarm 0044 Alarm flag 1 1 :01 03 0044 0001 B7 [CR][LF] :01 03 02 8000 7A [CR][LF] ERR15 :01 06 0050 0 A9 [CR][LF] :

Host STX 31H Setting data ETX Check sum CR 101 100 10-1 10-2 () () Thermo-con ACK CR Host SOH UT STX 31H Setting data ETX Check sum CR 101 100 10-1 10-2 () () Thermo-con ACK UT CR 4-2 Reading setting temperature As 0.1 deg.C is the minimum unit, the number in the hundredths place (10-2) is always 0 (=30H).

Fluid name Applicable element Air (Dry) Lubricating oil (20 mm2/s) Industrial water Fragrances (1 mm2/s) Nominal filtration accuracy (m) Cotton Polypropylene Paper Micromesh Applicable filter model 0.5 Note 1) 10 Note 1) 1 5 10 20 10 5 FGDCA 110 550 11 21 23 26 22 29 03 FGDEA 110 750 12 27 30 36 28 42 04 FGDTA 110 1000 13 32 36 46 32 57 06 FGDFA FGDCB 200 600 17 25 26 28 26 30 03 FGDEB 200

ZP3(10/13/16) UM: ZP3(10/13/16) B: ZP3(10/13/16) UM: ZP3(10/13/16) B: ZP3(10/13/16) UM: ZP3(10/13/16) B: ZP3(10/13/16) UM: ZP3(10/13/16) B: ZP3(10/13/16) UM: ZP3(10/13/16) B: ZP3-T (10/13/16) UM:-A5 ZP3-T (10/13/16) B:-A5 ZP3-T (10/13/16) UM:-B5 ZP3-T (10/13/16) B:-B5 ZP3-T (10/13/16) UM:-A12-@ ZP3-T (10/13/16) B:-A12-@ ZP3-T (10/13/16) UM:-A12-04 ZP3-T (10/13/16) B:-A12-04 ZP3-T (10/13/16

ZP3(10/13/16) UM: ZP3(10/13/16) B: ZP3(10/13/16) UM: ZP3(10/13/16) B: ZP3(10/13/16) UM: ZP3(10/13/16) B: ZP3(10/13/16) UM: ZP3(10/13/16) B: ZP3(10/13/16) UM: ZP3(10/13/16) B: ZP3-T (10/13/16) UM:-A5 ZP3-T (10/13/16) B:-A5 ZP3-T (10/13/16) UM:-B5 ZP3-T (10/13/16) B:-B5 ZP3-T (10/13/16) UM:-A12-@ ZP3-T (10/13/16) B:-A12-@ ZP3-T (10/13/16) UM:-A12-04 ZP3-T (10/13/16) B:-A12-04 ZP3-T (10/13/16

10 to 16 (Thin section series) 2 to 8 10 to 16 20 to 32 40, 50 2 x 4, 3.5 x 7, 4 x 10 10 to 16 (Thin section series) 2 to 8 10 to 16 20 to 32 40 to 50 4, 6 Nylon tube, 4, 6 Urethane tube Vacuum entry Thread dia.

B 9 18 () 22 10 SOL. A 23 6 () 11 Station 8 SOL.

Inch size Metric size Port size 4 04 03 5/32 M5 M5 x 0.8 Thread type 6 06 07 1/4 U10/32 10-32 UNF 8 08 09 5/16 Metric thread (M5) 01 1/8 Nil 10 10 11 3/8 Unified thread (10-32 UNF) 02 1/4 12 12 13 1/2 R 03 3/8 N NPT 04 1/2 Check valve free flow direction Applicable Tubing O.D./Port Size Combinations From male thread to One-touch fitting A Metric size Inch size Applicable tubing O.D.

ZP3(10/13/16) UM: ZP3(10/13/16) B: ZP3(10/13/16) UM: ZP3(10/13/16) B: ZP3(10/13/16) UM: ZP3(10/13/16) B: ZP3(10/13/16) UM: ZP3(10/13/16) B: ZP3(10/13/16) UM: ZP3(10/13/16) B: ZP3-T (10/13/16) UM:-A5 ZP3-T (10/13/16) B:-A5 ZP3-T (10/13/16) UM:-B5 ZP3-T (10/13/16) B:-B5 ZP3-T (10/13/16) UM:-A12-@ ZP3-T (10/13/16) B:-A12-@ ZP3-T (10/13/16) UM:-A12-04 ZP3-T (10/13/16) B:-A12-04 ZP3-T (10/13/16

Model: 11 (Port A One-touch Fitting, Port B One-touch Fitting), Applicable Tube OD: 09 (5/16"), Port Size Applicable Tube: 13 (1/2"), Number of Ports: 10 pcs.

Metric size Inch size Body size Port size 3 1/8 standard 06 6 07 1/4 Symbol Cylinder side 4 1/4 standard 08 8 09 5/16 01 R1/8 5 3/8 standard 10 10 11 3/8 02 R1/4 6 1/2 standard 12 12 13 1/2 03 R3/8 04 R1/2 N01 NPT1/8 N02 NPT1/4 N03 NPT3/8 N04 NPT1/2 XTO Series Applicable tubing O.D.

NBR FKM KA00809 KA00725 Quantity 1 1 1A-P85 4D-P85 FNR100N-10 1.1 L Rc1 Stainless steel 304 FNR100V-10 FNR101N-10 FNR101V-10 Model Tank capacity Port size 1.8 L KA00809 4 O-ring Industrial Filters Replacement Procedure Actuators Modular F.R.L.

NBR FKM KA00809 KA00725 Quantity 1 1 1A-P85 4D-P85 FNR100N-10 1.1 L Rc1 Stainless steel 304 FNR100V-10 FNR101N-10 FNR101V-10 Model Tank capacity Port size 1.8 L KA00809 4 O-ring Industrial Filters Replacement Procedure Actuators Modular F.R.L.

/I.D. mm 8/5 9/6 10/6.5 12/8 12.5/8.5 16/11 Symbol 01 02 03 04 06 Symbol 50 60 65 80 85 110 Symbol 04 06 08 10 12 16 Thread size R, Rc 1/8 R, Rc 1/4 R, Rc 3/8 R, Rc 1/2 R, Rc 3/4 Tubing O.D. mm 4 6 8 10 12 16 Construction Description Material Plug Description Material Socket Note Note Electroless nickel plated No. 1 14 15 No. 1 2 3 4 5 6 7

Metric size Inch size 1 2 3 4 5 6 7 8 9 M 1 station Elbow Straight Elbow OUT side IN side Straight 6 Elbow Straight Elbow OUT side IN side Straight 2 stations Symbol Symbol Note) 3 stations 8 10 6 8 10 4 6 4 6 1/4 5/16 3/8 1/4 5/16 3/8 5/32 1/4 5/32 1/4 4 stations 07 08 09 10 11 12 19 20 21 22 23 24 26 27 28 29 30 31 33 34 35 36 37 38 57 58 59 60 61 62 69 70 71 72 73 74 76 77 78 79 80