Applicable model t ZH15DA-09-N03-11 ZH15DA-N02-N03-N03 2 Minimum C Factor of a Supply Valve Model C[dm3/(sbar)] ZH05A 0.12 ZH07A 0.23 ZH10A 0.47 ZH13A 0.80 ZH15A 1.06 ZH18A 1.53 ZH20A 1.88 ZH18DA-11-N03-13 ZH18DA-N03-N03-N03 1 ZH20DA-10-04-12 ZH20DA-03-04-04 ZH20DA-11-N04-13 ZH20DA-N03-N04-N04 t 2.
Applicable model 84 84 03 FGD-CV002-04 06 03 FGD-CV003-04 06 03 FGD-CV004-04 06 03 FGD-CV001-04 06 32 32 FGDT/F FGDT/F FGDC/E FGDC/E Note 1) Same as standard product except for cover assembly Note 2) 03, 04, and 06 indicate the relevant port sizes (Rc3/8, 1/2, 3/4).
) 3/4B (06) 1B (08) 1 1/4B (10) 1 1/2B (12) 2B (16) 2 1/2B (20) 3B (24) 1/2B (04) 3/4B (06) 1B (08) 1 1/4B (10) 1 1/2B (12) 2B (16) 1/2 3/4 1 1 1/4 1 1/2 2 22.2 27.7 34.5 43.9 49.1 61.1 77.1 90.0 2.7 2.7 2.7 5.1 5.1 5.0 10.3 10.3 1/2B (04) 3/4B (06) 1B (08) 1 1/4B (10) 1 1/2B (12) 2B (16) 2 1/2B (20) 3B (24) 22.2 27.7 34.5 43.9 49.1 61.1 77.1 90.0 56 56 56 76 76 76 101 101 71 71 71 104 104
Status (2): The circulating fluid temperature becomes within the set range of "AS.04". "AS.04" alarm monitoring starts. Status (3): The circulating fluid temperature exceeds the threshold of "AS.06", but the alarm will not be generated as it has returned within the 600 sec range of the "AS.23: Range over detecting timer".
Status (2): The circulating fluid temperature becomes within the set range of "AS.04". "AS.04" alarm monitoring starts. Status (3): The circulating fluid temperature exceeds the threshold of "AS.06", but the alarm will not be generated as it has returned within the 600 sec range of the "AS.23: Range over detecting timer".
Status (2): The circulating fluid temperature becomes within the set range of "AS.04". "AS.04" alarm monitoring starts. Status (3): The circulating fluid temperature exceeds the threshold of "AS.06", but the alarm will not be generated as it has returned within the 600 sec range of the "AS.23: Range over detecting timer".
Status (2): The circulating fluid temperature becomes within the set range of "AS.04". "AS.04" alarm monitoring starts. Status (3): The circulating fluid temperature exceeds the threshold of "AS.06", but the alarm will not be generated as it has returned within the 600 sec range of the "AS.23: Range over detecting timer".
Status (2): The circulating fluid temperature becomes within the set range of "AS.04". "AS.04" alarm monitoring starts. Status (3): The circulating fluid temperature exceeds the threshold of "AS.06", but the alarm will not be generated as it has returned within the 600 sec range of the "AS.23: Range over detecting timer".
7) IS1000M-60 IS1000M-50 Y510-(02) 03 IS1000M-20 IS1000M-30 IS1000M-40 IS1000M-50 IS1000M-60 Y610-03 (04) Y610-(03) 04 T-interface Note 6) Note 7) Y110-M5 Y110-M5 VHS20-01 02 VHS50-06 10 3-port valve for residual pressure release Note 7) VHS30-02 03 VHS40-06 01 E200-02 03 02 E300-03 04 E600-06 10 E100-M5 Piping adapter Note 7) E500-06 E100-M5 01 IS1000E-2002 03 02 IS1000E-3003 04 Pressure
How to Order Sub-plates 04 P VQ5000 Electrical entry Port size Replacement of pilot valve assembly (Voltage) Refer to pages 2-6-40 to 2-6-41 for pilot valve assembly part numbers. Refer to page 2-6-3 for replacement method. 04 Rc 1/2 Porting specifications P S Plug-in conduit terminal Plug lead Note1) For bottom ported, port size is Rc 1/2.
2 Without sub-plate 1 4 3 8 1 2 4 JIS Symbol Note) A M5 01 02 02 03 04 04 06 10 10 12 14 20 Note) M5 1 8 1 4 1 4 3 8 1 2 1 2 3 4 1 Note) Note) 3 Body ported 5 1 1 11 4 7 1 4 11 2 1 2 2 9 Note) Only bracket or foot may be mounted. 14-10-2 3 E-P HYREG Series VY1 Standard Specifications 02 03 04 04 06 10 02 03 04 VY1A0 0 1-M5 VY1B0 0 1M 0 5 1 VY110 0 10 0 1 2 VY120 0 10 0 1 2 VY130 0 1VY140
14, 38, 12 67 36 36 NAK6000-N06, 10 34, 1 95 50 50 H O W T O O R D E R ( N ) A K 2 0 0 0 S E R I E S 000 (N)AK P O R T S I Z E M O D E L 01 1/8 02 1/4 03 3/8 04 1/2 06 3/4 10 1 P O R T T H R E A D 2 1/4 4 1/2 6 1 Nil Rc(PT)* N NPT F G(PF)* * Remove N when ordering Courtesy of Steven Engineering, Inc. !
7) IS1000M-60 IS1000M-50 Y510-(02) 03 IS1000M-20 IS1000M-30 IS1000M-40 IS1000M-50 IS1000M-60 Y610-03 (04) Y610-(03) 04 T-interface Note 6) Note 7) Y110-M5 Y110-M5 VHS20-01 02 VHS50-06 10 3-port valve for residual pressure release Note 7) VHS30-02 03 VHS40-06 01 E200-02 03 02 E300-03 04 E600-06 10 E100-M5 Piping adapter Note 7) E500-06 E100-M5 01 IS1000E-2002 03 02 IS1000E-3003 04 Pressure
AS2001FM-04-X12 Ex.) AS2001FM-04-X21 AQ Note 1) Not particle-free ASV Throttle Valve (Without Check Valve) X214 AK Ex.) AS2001FM-04-X214 VCHC ASR ASQ Needle Valve/Flow Rate Characteristics Note) The flow rate characteristics are representative values.
Also, take measures to prevent ingress of water and foreign matter from the breathing port of the diaphragm. 5-5-10 1 3 Port Air Operated Valve Series VGA342 How to Order SA 04 VGA342 A VA Port size Passage A Normally closed (N.C.) B Normally open (N.O.) Thread type Nil Rc F G N NPT T NPTF 04 1/2 06 3/4 10 1 SA VA JIS Symbol VM N.C. N.O.
M3 M3x0.5 M5 M5x0.8 01 18 02 14 03 38 04 12 Courtesy of Steven Engineering, Inc. !
A White Normally Open B Red Normally Closed Mounting & Wiring ZSE ISE IFW50--01 to 04/11 to 14/21 to 24 Caution PSE 1. Mount a switch, so that the liquid flow is in the same direction as that of the arrow on the body. 2. The flow switch can be installed either horizontally or vertically. 3.
type: White color L type: Black color (Mounting hole) B C D E F G H Model A 3 8 Rc3 8 Rc3 8 Rc3 8 ZH18DS-03-03-03 ZH18DL-03-03-03 ZH20DS-03-04-04 ZH20DL-03-04-04 Rc 133 52.45 42 19 3.5 19 20.95 20.95 133 52.45 42 19 3.5 19 151.1 60.95 47.7 19 3.5 24 26.75 151.1 60.95 47.7 19 3.5 24 26.75 I J K L M N O Model 3 8 Rc3 8 Rc3 8 Rc1 2 Rc1 2 ZH18DS-03-03-03 ZH18DL-03-03-03 ZH20DS-03-04-04 ZH20DL
-X538 34.4 75.2 118.7 262.7 AW40-04G-A Y400T-A E400-04-A VP744-5DZ1-04-X555 34.4 75.2 160.2 304.2 AW40-04G-A Y400T-A E400-04-A 17 VP500/700-X536, X538, X555 Specific Product Precautions Be sure to read this before handling.
Metric sizes Type 04 06 08 10 12 4 6 8 10 12 2 Elbow Control type 0 1 Meter-out Meter-in Port size M5 01 02 03 04 M5 x 0.8 1/8 1/4 3/8 1/2 With One-touch fitting Clean specifications Metal parts material Q G Brass (electoless nickel plated) Stainless steel 304 Needle Valve/Flow Characteristics AS121FP-M5 AS221FP-01 AS221FP-02 08,10 06,08 06 04 04 AS321FP-03 AS421FP-04 12 10 10,12 08 06 15