Do not drop, bump, or apply excessive impacts (300 m/s2 or more for reed switches and 1000 m/s2 or more for solid state switches) while handling. Although the body of the switch may not be damaged, the inside of the switch could be damaged and cause a malfunction. 2. Do not carry a cylinder by the auto switch lead wires. Never carry a cylinder by its lead wires.
Do not drop, bump, or apply excessive impacts (300 m/s2 or more for reed switches and 1000 m/s2 or more for solid state switches) while handling. Although the body of the switch may not be damaged, the inside of the switch could be damaged and cause a malfunction. 2. Do not carry a cylinder by the auto switch lead wires. Never carry a cylinder by its lead wires.
Do not drop, bump, or apply excessive impacts (300 m/s2 or more for reed switches and 1000 m/s2 or more for solid state switches) while handling. Although the body of the switch may not be damaged, the inside of the switch could be damaged and cause a malfunction. 2. Do not carry a cylinder by the auto switch lead wires. Never carry a cylinder by its lead wires.
rate: 50% Stroke 300 mm Series MB, CA2 Pressure 0.5 MPa Load rate: 50% Stroke 500 mm Average speed (mm/s) Series 800 700 600 500 400 300 200 100 0 Perpendicular, upward actuation SY3140-01 Horizontal actuation 800 700 600 500 400 300 200 100 0 SY5140-02 800 700 600 500 400 300 200 100 0 SY7140-03 800 700 600 500 400 300 200 100 0 SY9140-04 Cylinder is in extending.
Standard length is 300 mm, but the following lengths are also available.
Standard length is 300 mm, but the following lengths are also available.
72 64 [65.3] 123 87.8 [90.4] 103.8 [106.4] (Lead wire length) 300 41.6 300 54 [60.5] (Lead wire length) [ ] for AC Other dimensions are the same as the grommet style
cable L: With lead wire (Length 300 mm) M: With lead wire (Length 300 mm) M: Common exhaust for the pilot and main valve + + + D: Push-turn locking slotted type + R port P, E port H: Lead wire length 600 mm Pilot valve exhaust is centralized to main valve.
Non-locking push type Manual override Lubrication Mounting orientation Shock/Vibration resistance (m/s2) (2) Not required Unrestricted 300/50 Dustproof Note 1) Based on dynamic performance test, JIS B 8374-1981.
Body Ported Bore size Series CJ2 Pressure 0.5 MPa Load factor 50% Stroke 60 mm Series CM2 Pressure 0.5 MPa Load factor 50% Stroke 300 mm Series MB/CA1 Pressure 0.5 MPa Load factor 50% Stroke 500 mm Average speed (mm/s) Series 6 10 16 20 25 32 40 40 50 63 80 100 800 700 600 500 400 300 200 100 0 Perpendicular, upward actuation Horizontal actuation VQZ1121-C6 Courtesy of Steven Engineering,
[87.1] (Lead wire length) 300 57.1 [ ] for AC Other dimensions are the same as the grommet
Standard length is 300 mm, but the following lengths are also available.
Lubrication Not required Mounting orientation Unrestricted 300/50 Note 2) Impact/Vibration resistance (m/s2) Note 1) In the case of single type, be certain that pressure within operating pressure range be supplied to supply port, because return pressure is introduced from supply port {1(P)} for activation.
0 100 200 300 0 100 200 300 0 Detection distance (m) Detection distance (m) Detection distance (m) Example 1) When requiring 300m detection, select the detection nozzle of 1.0 with supply pressure 0.2MPa.
Conversion example for a 8[mm] lead actuator driven at an acceleration of 3000 [mm/sec2] Acceleration/Deceleration time constant (ms) = {3000 (r/min) 60 (S) } 8 (mm) 1000 3000 (mm/s2) Rated Motor Rotation Speed (mm/s) Acceleration time constant/deceleration time constant (ms) = {Rated rotation speed (r/min) 60 (S) } x screw lead (mm) x 1000 Acceleration/deceleration speed (mm/s2) *Note)
acceleration, in X, Y, Z directions, for 2 hours each (De-energized) 300 m/s2 in X, Y, Z directions, 3 times each (De-energized) 3% F .S. or less (Based on 25C) 4.8 (4.4 in the end) resin piping (Applicable to I.D. 4 air tubing) Resin pipe: Nylon, Piston area of sensor: Silicon Environmental resistance Vibration resistance Impact resistance Temperature characteristics Port size Material
0 50 100 150 200 250 0 0 50 50 100 100 0.5 s 0.5 s 150 150 1 s 1 s 200 200 2 s 250 250 2 s 5 s 5 s 300 300 421 IZS40/41/42 Series Note) Static neutralization features are based on the data using the charged plate (size: 150 mm x 150 mm, capacitance: 20 pF) as defined in the U.S.
size 15 Symbol 40mm Nil 20, 25, 32, 40 TN TF Standard Stroke Note 1) Bore size (mm) Standard stroke (mm) Maximum stroke availabe (mm) 50, 100, 150, 200, 250, 300, 350 400, 450, 500 15 1000 Note 2) 20 1500 100, 150, 200, 250, 300, 350, 400, 450 500, 600, 700, 800 25, 32 3000 100, 150, 200, 250, 300, 350, 400, 450 500, 600, 700, 800, 900, 1000 40 3000 Note 1) Contact SMC if the maximum stroke
Indicator light Lead wire Flexible fluorine resin heavy-duty cable, 6, 0.5mm2, 2 cores, 300 mm Impact resistance Switch part : 1000 m/s2, Connector part : 300 m/s2 Insulation resistance 50 M or more at 500 VDC (between lead wire and case) Withstand voltage 1000 VAC for 1 minute (between lead wire and case) Ambient temperature 10 to 60C Enclosure IEC529 standard IP67, JIS 0920 Watertight