Standard Stroke Maximum stroke available (mm) Bore size (mm) Standard stroke (mm) 10 50, 100, 150, 200, 250, 300 500 15 50, 100, 150, 200, 250, 300, 350, 400, 450, 500 750 25 100, 150, 200, 250, 300, 350, 400, 450, 500, 550, 600 1200 The stroke is available in 1 mm increments with the maximum stroke as the upper limit.

Models/Specifications MHS3-16D MHS3-20D MHS3-25D MHS3-32D MHS3-40D MHS3-50D MHS3-63D MHS3-80D MHS3-100D MHS3-125D Model Cylinder bore size (mm) 16 20 25 32 40 50 63 80 100 125 Air Fluid Operating pressure (MPa) 0.2 to 0.6 0.1 to 0.6 Ambient and fluid temperature (C) 10 to 60 0.01 Repeatability (mm) 60 Max. operating frequency (c.p.m.) 120 30 Not required Lubrication Double acting Action 25 750

Maximum acceleration: 2000mm/s Positioning time (sec.) 1500 750 100 10 1 Positioning distance (mm) 151.1 76.1 11.1 2.1 1.2 10 16.1 8.6 2.1 1.2 1.1 100 Speed (mm/s) The value is a guide when SMC's series LCI controller is used and may vary depending on the driver capacity. 7.2 4.2 1.6 1.2 1.1 250 4.3 2.8 1.5 1.2 1.1 500 Values will vary slightly depending on the operating conditions.

OUT1OUT2OUT3OUT4OUT5 AC100~240V Pulse counter M/C Flow control for each branch line For Air P.2 50l/min 10l/min 500l/min 200l/min 100l/min 12000l/min 6000l/min 3000l/min Flow rate measurement range l/min Integrated display type Remote type Output specifications Port size (Rc, NPT, G) 1/8 1/4 3/8 1/2 11/2 1 2 Switch output Analog output Accumulated pulse output Display unit Sensor unit PF2A710 750

Rc NPT G Symbol N M12 3 m lead wire with connector Without lead wire Note) Fixed units: Real-time flow rate: l/min Accumulated flow: l Port size Output specification Port size Applicable model Flow rate (l/min) Symbol Symbol Output specification 100 200 500 50 10 01 02 03 04 1/8 1/4 3/8 1/2 27 NPN open collector 2 outputs PF2A710/750 PF2A711/721 PF2A751 67 PNP open collector 2 outputs

OUT1OUT2OUT3OUT4OUT5 AC100~240V Pulse counter M/C Flow control for each branch line For Air P.2 50l/min 10l/min 500l/min 200l/min 100l/min 12000l/min 6000l/min 3000l/min Flow rate measurement range l/min Integrated display type Remote type Output specifications Port size (Rc, NPT, G) 1/8 1/4 3/8 1/2 11/2 1 2 Switch output Analog output Accumulated pulse output Display unit Sensor unit PF2A710 750

.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 1/8 1/4 3/8 1/2 11/2 1 2 Switch output Analog output Accumulated pulse output Display unit Sensor unit PF2A710 750 711 721 751 703H 706H 712H PF2A510 550 511 521 551 1 to 10 PF2A30 5 to 50 10 to 100 31 20 to 200 50 to 500 150 to 3000 300 to 6000 600

PAT. 17-5-172 33 Flow Switch Series PF, IF For Air Digital Flow Switch/Series PFA Display integral type Output specification Port size (Rc, NPT, G) Flow rate range (l/min) Separate type Display Sensor Switch output Analog output Accumulated pulse output PFA710 750 711 721 751 703H 706H 712H PFA510 550 511 521 551 1 to 10 5 to 50 10 to 100 20 to 200 50 to 500 150 to 3000 300 to 6000 6000 to

VQZ3000 0.9 1.2 Bore size (mm) Cv Cylinder speed (mm/s) Series CJ2 Series CM2 Series CA1 Base mounted (With sub-plate) 6 10 16 20 25 32 40 40 50 63 80 100 150 300 V V VQZ1000 Body width 10 450 0.35 V V V 600 750 150 300 VQZ2000 Body width 15 0.7 450 V V V V V 600 750 150 300 VQZ3000 Body width 18 1.2 450 V V V V V 600 750 Cylinder speed marked with V can be controlled by speed controller.

VQZ3000 VFS VS 0.7 0.9 VS7 Bore size (mm) Cylinder speed (mm/s) Base mounted (With sub-plate) Cv Series CJ2 Series CM2 Series CA1 6 10 16 20 25 32 40 40 50 63 80 100 150 300 VQZ1000 Body width 10 450 0.3 V V V 600 750 150 300 VQZ2000 Body width 15 0.6 450 V 600 V V 750 150 300 VQZ3000 Body width 18 0.9 450 V V V V V 600 750 Cylinder speed marked with can be controlled by speed controller

Action Single acting, Single rod Fluid Air Proof pressure 1.5 MPa Max. operating pressure 1.0 MPa Min. operating pressure Rubber bumper Spring return: 0.18 MPa Spring extend: 0.23 MPa Ambient and fluid temperature Without auto switch: 20C to 80C (No freezing) With auto switch: 10C to 60C (No freezing) Lubricant Not required (Non-lube) Stroke length tolerance +1.4 0 mm Piston speed 50 to 750

Standard Stroke Maximum manufacturable stroke (mm) Bore size (mm) Standard stroke (mm) 10 50, 100, 150, 200, 250, 300 500 15 50, 100, 150, 200, 250, 300, 350, 400, 450, 500 750 25 100, 150, 200, 250, 300, 350, 400, 450, 500, 550, 600 1200 The stroke is available in 1 mm increments with the maximum stroke as the upper limit.

The load kinetic energy can be obtained by the following equation: 5 a 1 Rush speed into cushion (mm/s) 100 50 200 500 750 M Also, selection can be made by using the graph above. Example) Find the maximum load weight when using a cylinder with 32, stroke 500 mm, with rear plate as a lifter at an average speed of a 300 mm/s.

st 1 600 st 400 st 500 st st: Stroke (mm) 0.5 100 st 200 st 300 st 0 0 50 100 150 200 250 300 350 400 450 500 550 600 Allowable end load F (N) MGGM100Stroke 4 (Slide bearing type) 3.5 3 1300 st Deflection Y (mm) 2.5 1200 st 1100 st 2 1000 st 1.5 900 st 800 st 1 600 st 700 st st: Stroke (mm) 400 st 500 st 0.5 100 st 200 st 300 st 0 0 100 50 150 200 250 300 350 400 450 500 550 600 650 700 750

Static Neutralization Characteristics e Potential Amplitude IZS40, 41 Supply pressure: 0.3 MPa With high speed de-ionizing cartridge With energy saving type de-ionizing cartridge 2000 2000 1750 1750 Potential amplitude (V) Potential amplitude (V) 1500 1500 1250 1250 1000 1000 1 Hz 1 Hz 30 Hz 750 750 30 Hz 500 500 250 250 0 0 0 500 1,000 1,500 2,000 0 500 1,000 1,500 2,000 Installation distance

10 to 1500 psig (0.07 to 10.3 MPa) 15 to 2500 psig (0.1 to 17.2 MPa) 25 to 4000 psig (0.17 to 27.6 MPa) 50 to 6000 psig (0.34 to 41.4 MPa) 100 to 10 psig (0.7 to 69 MPa) Operating Parameters Delivery pressure Gas Source pressure Select compatible materials of construction for the gas SS body (Material code C or S): 69 MPa (10 psig) 2), Brass body (Material code B): 41.4 MPa (6000 psig) 750

inlet Ventilation air outlet 715 40 or less 954 330 10 1538 A 1026 984 627 677 Anchor bolt mounting position (View A) For piping port sizes, refer to the Parts Description on page 330. 328 HRL Series Dual Channel Refrigerated Thermo-chiller for Lasers Dimensions HRL300-Am-20 Ventilation air inlet Ventilation air inlet Ventilation air outlet 850 40 or less 1079 330 10 1839 A 1145 1109 700 750

25~600 1100 900 100 25~750 25~600 1100 850 4-2 CEU2 NPN P PNP 15 4-3 CE1-R 5 5m 10 10m C 15 15m 20 20m A B CD E F G () 16 5. 5-1 17 18 5-2 19 5-3 20 6. 6-1 1 3 4 7 5 2 6 8 9 10 11 6-2 1 11 10 9 2 3 4 5 6 7 8 12 AC DC LCD 21 7. 7-1 7-1-1 1 ISO VG32 060 1m 7-1-2 M4 DIN [050] [25%85%] [1055Hz 0.75mmXYZ 2 ] 7-2 7-2-1 AC100V15AC85VAC115V 50/60Hz DC24V100.4A 2 0.75mm

Stroke [mm] 100 to 500 100 to 500 200 to 600 Horizontal 10 20 20 30 40 45 30 50 60 Work load [kg] Note1) Vertical 4 8 15 5 10 20 7 15 30 Up to 400 1500 900 450 1500 1000 500 1500 1000 500 401 to 500 1200 720 360 1500 1000 500 1500 1000 500 501 to 600 900 540 270 1200 1000 500 1500 1000 500 601 to 700 700 420 210 930 620 310 1410 940 470 Speed [mm/s] Note2) Stroke 701 to 800 550 330 160 750

900 200 900 100 900 50 900 8 150 1000 75 1000 300 1000 200 1000 75 1000 9 200 1200 100 1200 400 1200 250 1200 100 1200 10 250 1400 125 1400 500 1400 300 1400 125 1400 11 300 1600 150 1600 600 1600 400 1600 150 1600 12 350 1800 175 1800 700 1800 500 1800 175 1800 13 400 2000 200 2000 800 2000 540 2000 200 2000 14 450 2500 225 2500 900 2500 600 2500 225 2500 15 700 3000 360 3000 1100 3000 750