This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CONTROLLER, ACTUATOR, ELECTRIC ACTUATOR, 2C, LE ACTUATOR, NO SIZE RATING, 1.98416 lb
port 1/8 12(PA) port 18 67 2 x 6.2 (For mounting) NO 2A NC 53 66 12 12 3R NC 1P (1/8) 12(PA) port 11.5 16 115.1 107.1 24 96.5 95.5 32.5 M5 x 0.8 (Breathing hole) 16 X 40 3/8, 1/2 1(P) port 80 03 04 A B For vacuum/VPA744V-13/8, 1/2 2(A) port 40 16 64 3/8, 1/2 3(R) port 24 18 67 2 x 6.2 (For mounting) NO 2A NC 53 66 12 3R NC 1P 1/8 12(PA) port 11.5 16 115.1 24 96.5 95.5 32.5 M5 x 0.8 (Breathing
(For mounting) 2 x 3 (Breathing hole) 70 51 4.4 1P 3EB 5EA 4.4 1/4, 3/8 [1 (P), 5 (EA), 3 (EB) port] 52 1504 5 Port Air Operated Valve VFA3000/5000 Series Single Unit Base Mounted RoHS How to Order Valve VFA 3 1 4 0 Base mounted (VFA1000: Not available) 02 Pilot port direction Series 3 5 VFA3000 VFA5000 Nil: Upward P: Lateral Pilot port Not available with the VFA1000.
1P 80 40 40 40 40 80 AN LECPA ( AN LECPA NPN NPN AP AP PNP PNP (m) () 8 8 8 8 L L 1.5 1 1.5 1 A A 10 10 3 3 3 3 B B 15 15 5 5 5 C C 20 20 5 () () R R S S / P.42 7.3 <> (NPNPNP) LEHF10K2-16 3 - 3.3 9 13 16 10 18 15 8 11 6 ( 12 4 5 7 2 1 3 17 14 1 2 A 3 B 4 + 5 6 + 7 + 8 9 10 A 11 B 12 13 NBR 14 15 16 17 18 ( DC24V) 4 - 4.
Sensor Resolution: 30 μm, Stroke: 20mm, Actuator Cable Length: 1m, Controller: PNP Controller, I/O Cable Length: -, Controller Mounting: -
Sensor Resolution: 30 μm, Stroke: 30mm, Actuator Cable Length: 1m, Controller: PNP Controller, I/O Cable Length: -, Controller Mounting: -
The rod type electric actuator LEY series has various body sizes with thrust equivalent to 16, 25, and 32 bore size. Direct or bracket mountings are available in three directions or types. Thrust, speed and positioning * can be managed with the use of an optional controller. Possible applications include transfer, opening and shutting, pressing, pushing, and press-fitting.Three body sizes
The rod type electric actuator LEY series has various body sizes with thrust equivalent to 16, 25, and 32 bore size. Direct or bracket mountings are available in three directions or types. Thrust, speed and positioning * can be managed with the use of an optional controller. Possible applications include transfer, opening and shutting, pressing, pushing, and press-fitting.Three body sizes
This is a legacy product. Please contact us for the latest version.sales@ocaire.com
Compatible Fluid: Air, Operating Environment: Standard, Type: Air Operating Type, Switching Type: Normally Closed, Connection Type: [Rc (R)] Rc, Plumbing Thread Nominal: 1/8, Driving Type: Pilot Type, Option: -, Pilot number: Single, Number Of Ports: 3, Pilot port piping method: Sub-plate side (internal), Body Type: Base Mounted Type
Size: 25, Bearing Type: M (Sliding Bearing), Motor Mounting: Top Mounting Type, Motor Type: Step Motor (Servo/24VDC), Lead: A (Size 16: 10mm, Size 25: 12mm, Size 32/40: 16mm), Stroke: 50mm, Motor Option: w/o Option, Guide Option: w/o Guide, Actuator Cable Type: w/o Cable, Actuator Cable Length: w/o Cable, Controller Type for (LEC, JXC): 1P (LECP1, PNP, Programless Type)
Size: 25, Bearing Type: M (Sliding Bearing), Motor Mounting: Top Mounting Type, Motor Type: Step Motor (Servo/24VDC), Lead: B (Size 16: 5mm, Size 25: 6mm, Size 32/40: 8mm), Stroke: 50mm, Motor Option: w/o Option, Guide Option: w/o Guide, Actuator Cable Type: w/o Cable, Actuator Cable Length: w/o Cable, Controller Type for (LEC, JXC): 1P (LECP1, PNP, Programless Type)
Size: 32, Bearing Type: L ( Ball Bushing Bearing), Motor Mounting: D (In-line Type), Motor Type: Step Motor (Servo/24VDC), Lead: A (Size 16: 10mm, Size 25: 12mm, Size 32/40: 16mm), Stroke: 150mm, Motor Option: w/o Option, Guide Option: w/o Guide, Actuator Cable Type: w/o Cable, Actuator Cable Length: w/o Cable, Controller Type for (LEC, JXC): 1P (LECP1, PNP, Programless Type)
Size: 25, Motor Mounting Position: D (In-line Type), Motor: Step Motor (Servo 24 VDC), Lead Screw: B (Size 16: 5mm, Size 25: 6mm, Size 32/40: 8mm), Stroke: 150mm, Motor Option: None, Rod End Thread: Female, Mounting: Both Ends Tapped (Standard), Actuator Cable: Without Cable, Actuator Cable Length: Without Cable, Controller Type - LEC, JXC: 1P (LECP1, PNP, Programless Type)
Size: 25, Motor Mounting Position: Top Mounting, Stroke: 1500, Motor Option: w/o Option, Stroke Adjustment Unit: None, Actuator Cable Type: w/o Cable, Actuator Cable Length: w/o Cable, Controller Type - LEC, JXC: 1P (LECP1, Programless Type, PNP)
Size: 32, Motor Mounting Position: Top Mounting, Stroke: 1500, Motor Option: w/o Option, Stroke Adjustment Unit: None, Actuator Cable Type: w/o Cable, Actuator Cable Length: w/o Cable, Controller Type - LEC, JXC: 1P (LECP1, Programless Type, PNP)
Size: 25, Motor Mounting Position: L (Symmetric, Top Mounting), Stroke: 600, Motor Option: w/o Option, Actuator Cable Type: w/o Cable, Actuator Cable Length: w/o Cable, Controller Type - LEC, JXC: 1P (LECP1, Programless Type, PNP)
Size: 40, Motor Mounting Position: Top, Motor: Step Motor (Servo 24 VDC), Lead Screw: C (Size 16: 2.5mm, Size 25: 3mm, Size 32/40: 4mm), Stroke: 200mm, Motor Option: None, Rod End Thread: Female, Mounting: Both Ends Tapped (Standard), Actuator Cable: Without Cable, Actuator Cable Length: Without Cable, Controller Type - LEC, JXC: 1P (LECP1, PNP, Programless Type)
Size: 10, Motor Size: Standard, Lead Screw Type, mm: LEPS6: 8; LEPS10: 10, Stroke: 50mm, Motor Cable Mounting Direction: Top Entry, Actuator Cable Type: None, Actuator Cable Length, m: No Cable, Controller Type - LEC, JXC: LECP1, Programless Type, PNP, I/O Cable Length for LEC: -, Controller Mounting: -, Communication Plug Connector or I/O Cable Length for JXC: -
Size: 6, Motor Size: Standard, Lead Screw Type, mm: LEPS6: 4; LEPS10: 5, Stroke: 25mm, Motor Cable Mounting Direction: Top Entry, Actuator Cable Type: None, Actuator Cable Length, m: No Cable, Controller Type - LEC, JXC: LECP1, Programless Type, PNP, I/O Cable Length for LEC: -, Controller Mounting: -, Communication Plug Connector or I/O Cable Length for JXC: -