SYJ700 SYJ7000 SYJ7000 3 A B Assy SYJ700-3-1A(-Q) SYJ700-3-2A(-Q) SYJ700 SYJ700 M3 : 0.8N.m O 21 No.SYJ300-OMU0003 Assy SYJ72(R)(-Q)) (SYJ74(R)(-Q)) SYJ700-10-1A M3 : 0.8N.m :SYJ700-10-2A , (SYJ700-5-3) SYJ700-10-1AAss'y CE SYJ700-10-2A-1-Q SYJ700-10-2A-2Q 22 No.SYJ300-OMU0003 Assy 5 G V111 T S (DC24V,12V) Z *W R () U () 5 DC24V *AC S *RU DC *Z 6 DC12V V DC6V S DC5V G 300m
BAR NOZZLE, 300M, OTHERS, IZS/IZF IONIZER, 22, IZSE30 NO SIZE RATING
BENDER TUBE NOZZLE, 300M, OTHERS, IZS/IZF IONIZER, 22, IZSE30 NO SIZE RATING
LONG NOZZLE, 300M, OTHERS, IZS/IZF IONIZER, 22, IZSE30 NO SIZE RATING
BENDER TUBE NOZZLE, 300M, OTHERS, IZS/IZF IONIZER, 22, IZSE30 NO SIZE RATING, 0.70706 lb
Part Number Description: AUTO-SWITCH 300M SWITCH WIRE Product Line: A Product Line Description: ACTUATOR Family Code: 572 Family Description: AUTO-SWITCH ACCESSORY Class Code: 22 Part Code: 1 Reference Code: K This is a custom made item that is NOT returnableClick here to report information errorImage shown may not match exact part number
Auto Switch Common Specifications Auto switch style Solid state switch Reed switch Current leakage 3 wire: 100 A or less, 2 wire: 1mA or less None Operating time 1ms or less (3) 1.2ms Shock resistance 300m/s 2 1000m/s 2 Insulation resistance 50 M or more at 500MV DC (between lead wire and the case) 1000V AC/min. (between lead wire and the case) 1500V AC/min.
IP40 Operating: 0 to 50C, Stored: 20 to 70C (with no condensation and no freezing) Operating/Stored: 35 to 85%RH (with no condensation) 1000VAC or more, 50/60Hz for 1 minute between live parts and case 50M or more between live parts and case (at 500VDC) 10 to 150 Hz at whichever is smaller of 1.5mm amplitude or 100m/s2 acceleration, in X, Y, Z directions, for 2 hours each (de-energized) 300m
10 24VAC, DC or less 50mA MDSUB7, MDSUB20 D-R8 D-R801L D-R802L PLC 48VAC, DC 40mA 100VAC, DC 20mA D-S7 D-S791L D-S792L ACCESSORIES AUTO SWITCH POSITION SETTING PLC 5, 12, 24VDC 150mA D-S99 D-S991L D-S992L D-T7 D-T791L D-T792L PLC 24VDC 5~150mA D-T99 D-T991L D-T992L Response time . 1.2ms Ambient temperature . 5~60C Shock resistance Length of lead wire . 0.5m (standard) Reed switch type . 300m
G4*IE ilhr ilnrl|0ric H0rd Rc$i$rilrc0 $gnigS CIIZBP Grommet Sequence Controller DC24V 'K wtr 40mA Nol Available (o) 1.2mA RED LED at OFF Auto Switch Without lndicator Grommet Relay, Sequence Conlroller 100v 20mA D-P70 Surge Suppressor Nol available 1Q or less Lead wire oil proof, flame retardant (VW-1), heary insu aled cable o6.8, 0.75 mm,, 2 wirc (while and black). 0.sm. lmoact oroof. 300m
Do not drop, apply excessive impact (more than 300m/s2 for reed switch, more than 1000m/s2 for solid-state switch) when handling. Damage could occur to the inside as well as the body. 2.Do not pull the lead wire wiih excessive force. Do not pull the lead wile to move the cylinder.
3 cors (red, white. blackJ, 2 cores (rcd back), 0.5m long x 300m/S,{30.6G} Min. 50MQ (between lead wne and cas)as neasurd with a 500VOC a lnsulation reslsiancs 15mVAC ior l min.
Series MELSEC-A AJ71PT32-S3, AJ71T32-S3 A1SJ71PT32-S3 Max. 64 stations, connected to remote I/O stations (Max. 512 points). 16 outputs, 2 stations occupied. T unit Can be connected with PLC I/O card for serial transmission. EX300-TMB1For models of Mitsubishi Electric Corp. EX300-TTA1For models of OMRON Corp. EX300-TFU1For models of Fuji Electric Company Ltd.
No. of output points, 16 points Master station: PLC made by Mitsubishi Electric Corporation Series MELSEC-A AJ71PT32-S3, AJ71T32-S3 A1SJ71PT32-S3 Max. 64 stations, connected to remote I/O stations (Max. 512 points). No. of output points, 16 points. No. of sta. occupied, 2 stations Stations are counted from station 1 on the D side.
MELSECNET/MINI-S3 Data Link System Master unit: AJ71PT32-S3 AJ71T32-S3 A1SJ71PT32-S3 16 outputs, 2 occupied stations Connect to the I/O card of transmission PLC manufacturers to enable serial transmission. EX300-TMB1for Mitsubishi Electric Corporation EX300-TTA1.for OMRON corporation EX300-TFU1.for Fuji Electric Co., Ltd. EX300-T001.
Item Specification MELSECNET/MINI-S3 Data Link System Master unit: AJ71PT32-S3 AJ71T32-S3 A1SJ71PT32-S3 16 outputs, occupying two stations Connection to T unit PLC manufacturer's I/O card enables serial transmission. EX300-TMB1 ... for Mitsubishi Electric Corporation EX300-TTA1 ... for OMRON Corporation EX300-TFU1 ... for Fuji Electric Co., Ltd. EX300-T001 ...
ERR Item Specifications MELSECNET/MINI-S3 Data Link System Master unit : AJ71PT32-S3 AJ71T32-S3 A1SJ71PT32-S3 No. of output points, 16 points, No. of stations. occupied, 2 stations Connection to T unit PLC manufacturers I/O card enables serial transmission. EX300-TMB1 for Mitsubishi Electric Corporation EX300-TTA1 for OMRON Corporation EX300-TFU1 for Fuji Electric Co., Ltd.
EX300-T001General purpose MELSECNET/MINI-S3 Data Link System Master unit: AJ71PT32-S3 AJ71T32-S3 A1SJ71PT32-S3 No. of output point, 16 points No. of sta. occupied, 2 stations Each T unit has 32 control points.
Series MELSEC-A AJ71PT32-S3, AJ71T32-S3 A1SJ71PT32-S3 Max. 64 stations, connected to remote I/O stations (Max. 512 points). 16 outputs, 2 stations occupied.
A Controller type Motor type Power supply voltage Symbol Type AC servo motor (S2) Capacity Encoder LECSA1-S1 LECSA1-S3 LECSA2-S1 LECSA2-S3 LECSA2-S4 LECSB1-S5 LECSB1-S7 LECSB2-S5 LECSB2-S7 LECSB2-S8 AC servo motor (S2) 100 to 120 VAC 50/60 Hz S1 S3 S4 S5 S7 S8 100 W B Pulse input type (For absolute encoder) AC servo motor (S3) Pulse input type (For incremental encoder) Incremental AC servo