SMC Corporation of America
Elite Part Number Search
Search Results "LVM10R1-6B-10-Q"

Symbol: Body Ported, 2 Port, N.C., Port 1 IN, Port 2 OUT, Tubing Type, Function: Standard, Voltage: 12 VDC, Wetted Part Material: Plate: PEEK; Diaphragm: FKM, Sub-plate Material, Port Size, Reverse Mounting Prevention Pin: w/o Sub-plate, Option: Manual Override, Lead Wire Length: Plug Connector, 300mm, CE Compliant: CE Compliant

Symbol: Body Ported, 2 Port, N.C., Port 1 IN, Port 2 OUT, Tubing Type, Function: Standard, Voltage: 12 VDC, Wetted Part Material: Plate: PEEK; Diaphragm: FKM, Sub-plate Material, Port Size, Reverse Mounting Prevention Pin: w/o Sub-plate, Option: Manual Override, Lead Wire Length: Plug Connector, 300mm, CE Compliant: CE Compliant

Symbol: Body Ported, 2 Port, N.C., Port 1 IN, Port 2 OUT, Tubing Type, Function: Standard, Voltage: 12 VDC, Wetted Part Material: Plate: PEEK; Diaphragm: FKM, Sub-plate Material, Port Size, Reverse Mounting Prevention Pin: w/o Sub-plate, Option: Bracket + Manual Override, Lead Wire Length: 600mm, CE Compliant: CE Compliant

Symbol: Body Ported, 2 Port, N.C., Port 1 IN, Port 2 OUT, Tubing Type, Function: Standard, Voltage: 12 VDC, Wetted Part Material: Plate: PEEK; Diaphragm: FKM, Sub-plate Material, Port Size, Reverse Mounting Prevention Pin: w/o Sub-plate, Option: Bracket + Manual Override, Lead Wire Length: Plug Connector, w/o Connector, CE Compliant: CE Compliant

Symbol: Body Ported, 2 Port, N.C., Port 1 IN, Port 2 OUT, Tubing Type, Function: Standard, Voltage: 12 VDC, Wetted Part Material: Plate: PEEK; Diaphragm: FKM, Sub-plate Material, Port Size, Reverse Mounting Prevention Pin: w/o Sub-plate, Option: Bracket + Manual Override, Lead Wire Length: Plug Connector, w/o Connector, CE Compliant: CE Compliant

Symbol: Body Ported, 2 Port, N.C., Port 1 IN, Port 2 OUT, Tubing Type, Function: Standard, Voltage: 12 VDC, Wetted Part Material: Plate: PEEK; Diaphragm: FKM, Sub-plate Material, Port Size, Reverse Mounting Prevention Pin: w/o Sub-plate, Option: Bracket + Manual Override, Lead Wire Length: Plug Connector, 300mm, CE Compliant: CE Compliant

Symbol: Body Ported, 2 Port, N.C., Port 1 IN, Port 2 OUT, Tubing Type, Function: Standard, Voltage: 12 VDC, Wetted Part Material: Plate: PEEK; Diaphragm: FKM, Sub-plate Material, Port Size, Reverse Mounting Prevention Pin: w/o Sub-plate, Option: Bracket + Manual Override, Lead Wire Length: Plug Connector, 300mm, CE Compliant: CE Compliant

Symbol: 10R1 (Body Ported, 2 Port, N.C., Port 1 IN, Port 2 OUT, Tubing Type), Function: Standard, Voltage: 6 (12 VDC), Wetted Part Material: B (Plate: PEEK; Diaphragm: FKM)

Symbol: Body Ported, 2 Port, N.C., Port 1 IN, Port 2 OUT, Tubing Type, Function: Standard, Voltage: 12 VDC, Wetted Part Material: Plate: PEEK; Diaphragm: FKM, Sub-plate Material, Port Size, Reverse Mounting Prevention Pin: -, Option: -, Lead Wire Length: -, CE Compliant: -

(C) 55 50 60 70 80 IDU3D to 6D 45 50 55 65 75 IDU8D to 15C 45 50 55 65 70 IDU22C1, 37C1 40 45 50 55 60 IDU55C, 75C Ambient temperature (C) Outlet air pressure dew point (C) 15 10 5 15 10 5 15 10 5 15 5 10 5 15 10 1.35 1.35 0.60 1.35 1.35 0.60 1.35 1.35 0.60 1.35 0.60 1.35 0.60 1.35 1.35 25 1.35 1.05 0.50 1.35 1.05 0.50 1.35 1.10 0.50 1.35 0.60 1.20 0.55 1.35 1.25 30 1.25 0.95 0.45 1.25 0.95

Symbol: 10R1 (Body Ported, 2 Port, N.C., Port 1 IN, Port 2 OUT, Tubing Type), Function: Standard, Voltage: 6 (12 VDC), Wetted Part Material: B (Plate: PEEK; Diaphragm: FKM), Sub-plate Material, Port Size, Reverse Mounting Prevention Pin: w/o Sub-plate, Option: 1 (Bracket)

Symbol: 10R1 (Body Ported, 2 Port, N.C., Port 1 IN, Port 2 OUT, Tubing Type), Function: Standard, Voltage: 6 (12 VDC), Wetted Part Material: B (Plate: PEEK; Diaphragm: FKM), Sub-plate Material, Port Size, Reverse Mounting Prevention Pin: w/o Sub-plate, Option: 3 (Bracket + Manual Override)

Symbol: 10R1 (Body Ported, 2 Port, N.C., Port 1 IN, Port 2 OUT, Tubing Type), Function: Standard, Voltage: 6 (12 VDC), Wetted Part Material: B (Plate: PEEK; Diaphragm: FKM), Sub-plate Material, Port Size, Reverse Mounting Prevention Pin: w/o Sub-plate, Option: 2 (Manual Override)

Symbol: 10R1 (Body Ported, 2 Port, N.C., Port 1 IN, Port 2 OUT, Tubing Type), Function: Standard, Voltage: 6 (12 VDC), Wetted Part Material: B (Plate: PEEK; Diaphragm: FKM), Sub-plate Material, Port Size, Reverse Mounting Prevention Pin: w/o Sub-plate, Option: None, Lead Wire Length: 6 (600mm)

Symbol: 10R1 (Body Ported, 2 Port, N.C., Port 1 IN, Port 2 OUT, Tubing Type), Function: Standard, Voltage: 6 (12 VDC), Wetted Part Material: B (Plate: PEEK; Diaphragm: FKM), Sub-plate Material, Port Size, Reverse Mounting Prevention Pin: w/o Sub-plate, Option: None, Lead Wire Length: K (Plug Connector, 300mm)

Symbol: 10R1 (Body Ported, 2 Port, N.C., Port 1 IN, Port 2 OUT, Tubing Type), Function: Standard, Voltage: 6 (12 VDC), Wetted Part Material: B (Plate: PEEK; Diaphragm: FKM), Sub-plate Material, Port Size, Reverse Mounting Prevention Pin: w/o Sub-plate, Option: None, Lead Wire Length: KO (Plug Connector, w/o Connector)

Symbol: 10R1 (Body Ported, 2 Port, N.C., Port 1 IN, Port 2 OUT, Tubing Type), Function: Standard, Voltage: 6 (12 VDC), Wetted Part Material: B (Plate: PEEK; Diaphragm: FKM), Sub-plate Material, Port Size, Reverse Mounting Prevention Pin: w/o Sub-plate, Option: None, Lead Wire Length: KOZ (Plug Connector, w/o Connector)

Symbol: 10R1 (Body Ported, 2 Port, N.C., Port 1 IN, Port 2 OUT, Tubing Type), Function: Standard, Voltage: 6 (12 VDC), Wetted Part Material: B (Plate: PEEK; Diaphragm: FKM), Sub-plate Material, Port Size, Reverse Mounting Prevention Pin: w/o Sub-plate, Option: None, Lead Wire Length: KZ (Plug Connector, 300mm)

Symbol: Body Ported, 2 Port, N.C., Port 1 IN, Port 2 OUT, Tubing Type, Function: Standard, Voltage: 12 VDC, Wetted Part Material: Plate: PEEK; Diaphragm: FKM, Sub-plate Material, Port Size, Reverse Mounting Prevention Pin: w/o Sub-plate, Option: Bracket, Lead Wire Length: -, CE Compliant: -

Symbol: Body Ported, 2 Port, N.C., Port 1 IN, Port 2 OUT, Tubing Type, Function: Standard, Voltage: 12 VDC, Wetted Part Material: Plate: PEEK; Diaphragm: FKM, Sub-plate Material, Port Size, Reverse Mounting Prevention Pin: w/o Sub-plate, Option: Bracket + Manual Override, Lead Wire Length: -, CE Compliant: -