SMC Corporation of America
Elite Part Number Search
Search Results "MGPM40-50-HN-A93L"

Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 200, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Guided, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, End Locking: [Included] Presence, Cushion: Rubber Bumper on Both Ends, Port thread type: NPT, Auto Switches: A93,

Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 300, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Guided, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, End Locking: [Included] Presence, Cushion: Rubber Bumper on Both Ends, Port thread type: Rc, Auto Switches: A93, Lead

Bore Size: 40mm, Port Type: Rc (PT), Stroke: 50mm, Lock Position: Rear Locking, Manual Override: Non-locking Type, Auto Switch: Y7BA--Solid State, Water Resist., 2 Wire, Horizontal, Lead Wire or Prewired Connector: 3m, Number: -

Bore Size: 40mm, Port Type: Rc (PT), Stroke: 50mm, Lock Position: H (Rear Locking), Manual Override: N (Non-locking Type), Auto Switch: M9BV--Solid State, Gen. Purpose, 2 Wire, Vertical, Lead Wire or Prewired Connector: Z (5m)

Bore Size: 40mm, Port Type: Rc (PT), Stroke: 50mm, Lock Position: H (Rear Locking), Manual Override: N (Non-locking Type), Auto Switch: M9BW--Solid State, 2-color Indication, 2 Wire, Horizontal, Lead Wire or Prewired Connector: SDPC (0.5m Cord Length, M12-4 Pin Connector)

Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 50, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Guided, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, End Locking: [Included] Presence, Cushion: Rubber Bumper on Both Ends, Port thread type: NPT, Auto Switches: M9BV,

Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 50, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Guided, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, End Locking: [Included] Presence, Cushion: Rubber Bumper on Both Ends, Port thread type: NPT, Auto Switches: M9BW,

Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 50, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Guided, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, End Locking: [Included] Presence, Cushion: Rubber Bumper on Both Ends, Port thread type: NPT, Auto Switches: Y7B, Lead

Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 50, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Guided, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, End Locking: [Included] Presence, Cushion: Rubber Bumper on Both Ends, Port thread type: NPT, Auto Switches: Without

Bore Size: 40mm, Port Type: Rc (PT), Stroke: 50mm, Lock Position: H (Rear Locking), Manual Override: N (Non-locking Type), Auto Switch: P4DW--Solid State, 2-color Indication, Magnetic Field Resist., 2 Wire, Lead Wire or Prewired Connector: SC (0.3m Cord Length, M12-4 Pin Connector, 3 & 4 Out)

Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 50, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Guided, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, End Locking: [Included] Presence, Cushion: Rubber Bumper on Both Ends, Port thread type: NPT, Auto Switches: M9BV,

Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 50, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Guided, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, End Locking: [Included] Presence, Cushion: Rubber Bumper on Both Ends, Port thread type: NPT, Auto Switches: M9BW,

Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 50, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Guided, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, End Locking: [Included] Presence, Cushion: Rubber Bumper on Both Ends, Port thread type: NPT, Auto Switches: Y7B, Lead

Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 50, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Guided, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, End Locking: [Included] Presence, Cushion: Rubber Bumper on Both Ends, Port thread type: NPT, Auto Switches: Without

Bore Size: 40mm, Port Type: Rc (PT), Stroke: 50mm, Lock Position: Rear Locking, Manual Override: Non-locking Type, Auto Switch: P4DW--Solid State, 2-color Indication, Magnetic Field Resist., 2 Wire, Lead Wire or Prewired Connector: 0.3m Cord Length, M12-4 Pin Connector, 3 & 4 Out, Number: -

lo switches Bore sizel E--6,"'"-l IE ro.m I IE re '. 1 Port location on head cover stroke (l00ihs o Standard 50, 100, 150,200 50, 100, 150, 200, 300.400, 500,600 50, 100, 150. 200,300,400, 500,600,700,400 Doub e actino Sinole aclino sorinq relurn Sinale aclinq sprinq extend Se Caralog N301 ior slandard stroke Lenglhs on lypes otherrhan single rod 'lnrermedate shkes can b nanufacrured upon

' Dire.sioB olfFr ll'a. lle abole a t1e same ds hN u the basic tps (ar th6 bn).

' Dire.sioB olfFr ll'a. lle abole a t1e same ds hN u the basic tps (ar th6 bn).

40-140'F(5-m'c 2 -20 inch/sec {50 -500 mm/sec) 2 -30 jnch/sec (50-750 mm/sec) Not required (prelubricated at factory) Standard Stroke LLst Owhen mounting, completelyflush the piping and be careful that dust and chips do not erterthe cylinder. )Load of piston rod should always be aligned parallel with the cylinder axis.

40-140'F(5-m'c 2 -20 inch/sec {50 -500 mm/sec) 2 -30 jnch/sec (50-750 mm/sec) Not required (prelubricated at factory) Standard Stroke LLst Owhen mounting, completelyflush the piping and be careful that dust and chips do not erterthe cylinder. )Load of piston rod should always be aligned parallel with the cylinder axis.