SMC Corporation of America
Elite Part Number Search
Search Results "MXQ25-40C-M9BWL"

Bore Size: 20mm, Port Thread: M Thread: 6 to 15 Bore; Rc: 20 to 63 Bore, Symmetric Type: Standard, Stroke: 40mm, Adjuster: C (Both Side Adjusters/Metal Stoppers), Auto Switch: M9BW--Solid State, 2-color Indication, 2 Wire, Horizontal, Lead Wire or Prewired Connector: L (3m)

with the product as accessories. 5 Bernoulli Gripper ZNC Series Specifications Model ZNC20 ZNC30 ZNC40 ZNC60 ZNC80 Lifting force [N]*1, *3 5.2 10.7 13.8 28.3 65 Air consumption [L/min] (ANR)*2, *3 131 138 182 182 255 Type Bernoulli Fluid Air Operating pressure 0.1 to 0.5 MPa Proof pressure 0.75 MPa Aluminum 5 to 80C (0 to 50C) Ambient and operating temperatures*4 Body material Resin 5 to 40C

Arbitrary address Vendor ID 7 h (SMC Corporation) Product type 2 Bh (Generic Device) Product code DEh Serial communication USB2.0 (Full Speed 12 Mbps) Memory Flash-ROM LED indicator PWR, RUN, USB, ALM, NS, MS, L/A, 100 Lock control Forced-lock release terminal *4 Communication Cable length Actuator cable: 20 m or less Cooling system Natural air cooling Operating temperature range 0C to 40C

or less Isobutyl alcohol Note 1), 2) Temperature 40C or less Isopropyl alcohol Temperature 40C or less Note 1), 2) Hydrochloric acid Concentration 30% or less Note 2) Hydrogen peroxide Concentration 5% or less, Temperature 50C or less Nitric acid (except fuming nitric acid) Concentration 10% or less, Temperature 40C or less Note 2) Deionized water Sodium hydroxide (Caustic soda) Concentration

Fluid temperature and ambient temperature ranges are; 0 to 40C for ionizer, 0 to 50C for feedback sensor and auto balance sensor (high accuracy type), 0 to 40C for AC adapter, and 0 to 45C for remote controller. Do not use the sensor in locations where the temperature may change suddenly even if the ambient temperature range is within the specified limits, resulting in condensation. 2.

Time A (EQY25/Battery-less absolute) B Ambient temperature Pushing force set value [%] Duty ratio [%] Continuous pushing time [min] Duty ratio = A/B x 100 [%] 40C or less 50 or less 100 [Pushing force set value] is one of the step data input to the controller.

.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Motor capacity 200W 100W 200W 100W 5 to 40C 5 to 50C 5 to 40C 5 to 50C Operating temperature range Electric power 640VA 300VA 640VA 300VA Control system AC software servo/PTP control Position detection system Incremental encoder Home position return direction

.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Motor capacity 200W 100W 200W 100W 5 to 40C 5 to 50C 5 to 40C 5 to 50C Operating temperature range Electric power 640VA 300VA 640VA 300VA Control system AC software servo/PTP control Position detection system Incremental encoder Home position return direction

.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Motor capacity 200W 100W 200W 100W 5 to 40C 5 to 50C 5 to 40C 5 to 50C Operating temperature range Electric power 640VA 300VA 640VA 300VA Control system AC software servo/PTP control Position detection system Incremental encoder Home position return direction

5 to 40C 5 to 40C 5 to 40C Electric energy 180VA 640VA 300VA 300VA 640VA 100VA 300VA 640VA 640VA 300VA 180VA 300VA Control system AC software servo/PTP control Position detection system Incremental encoder Home position return function Maximum positioning point setting With magnet switch as adjacent switch, and encoder Z phase signal as home position signal.

Fluid Set pressure range Hysteresis ZY Air 0 to 101 kPa 3% Full span or less 3% Full span (5 to 40C) 5% Full span (0 to 60C) 12 to 24 VDC (Ripple 10% or less) M5 x 0.8 Note) If not operated within the specified range of pressure and temperature, trouble may be caused. ZQ 1% Full span Accuracy ZF Voltage Port size ZP ZCU AMJ Misc.

The base oil of grease in the cylinder may seep out of the tube, cover, or crimped part depending on the operating conditions (ambient temperature 40C or more, pressurized condition, low frequency operation). CS1 Releasing the Lock Warning CS2 1.

Allowable voltage range [V] Rated voltage [A] Single phase 200 to 230 VAC (50/60 Hz) Single phase 170 to 253 VAC Single phase 100 to 120 VAC (50/60 Hz) Single phase 85 to 132 VAC 1.5 24 VDC 21.6 to 26.4 VDC 0.5 6 inputs 4 outputs 1 M (when differential receiver), 200 k (when open collector) 0 to 65535 (Pulse command unit) 3 rotations Parameter setting USB communication 32 to 104F (0 to 40C

or less 65 or less 100 40C or less 95 or less 100 LEY32 Without Load 800 Lead 4: LEY32C Model Pushing speed [mm/s] Pushing force (Setting input value) Model Pushing speed [mm/s] Pushing force (Setting input value) 700 Lead 8: LEY32B 1 to 4 20% to 65% 1 to 4 40% to 95% 600 LEY25 LEY25A 5 to 20 35% to 65% 5 to 20 60% to 95% Lead 16: LEY32A 500 21 to

Solenoid valve part number Allowable voltage range [Ambient and fluid temperatures: 5C or higher and 40C or lower] LPV21-mm-T4 LPV21-6mm-T6(A) LPV22-mmm-T4A LPV22-mmm-T6A 7. Do not use the switch unless the equipment operates normally.

The specified ambient temperature range for ionizer is 0 to 50C, and for AC adapter is 0 to 40C. Avoid sudden temperature changes even within specified ambient temperature range, as it may cause condensation. 2. Do not use this product in an enclosed space. This product utilizes a corona discharge phenomenon.

The specified ambient temperature range is 0 to 40C.

Arbitrary address Vendor ID 7 h (SMC Corporation) Product type 2 Bh (Generic Device) Product code DEh Serial communication USB2.0 (Full Speed 12 Mbps) Memory Flash-ROM LED indicator PWR, RUN, USB, ALM, NS, MS, L/A, 100 Lock control Forced-lock release terminal *4 Communication Cable length Actuator cable: 20 m or less Cooling system Natural air cooling Operating temperature range 0C to 40C

Use the air dryer with an ambient temperature lower than 104F (40C). Avoid installation on machines for transporting, such as trucks, ships, etc.

Auto current down, Power down input Function Connector Connection method 5 to 40C Operating environment 35 to 85% (with no condensation) Connectors (receptacle, female terminal) Cable should be arranged by customer. Accessories CE marking 1. The combination of Series LC6D and Series LX has been certified for CE marking.