SMC Corporation of America
Elite Part Number Search
Search Results "NCDA1L250-6000"

Delivery Pressure: P [50 to 6000 psig (0.34 to 41.4 MPa)], Relieving: 1 (Self-relieving, Standard), Material: B (Brass), Ports: 4P (4 Ports), Connections: 4 (NPT 1/4 Inch), Gauge Port, Inlet: 60 [6000 psig (41 MPa)], Gauge Port, Outlet: 20 [2000 psig (14 MPa)], Pressure Gauge Unit: psig/bar (or None in Case of no Gauge), Main Valve Seat Material: Vespel®, Standard, O-ring Material: VitonÂ

Delivery Pressure: P [50 to 6000 psig (0.34 to 41.4 MPa)], Relieving: 1 (Self-relieving, Standard), Material: C (300 SS Series), Ports: 4P (4 Ports), Connections: 4 (NPT 1/4 Inch), Gauge Port, Inlet: 60 [6000 psig (41 MPa)], Gauge Port, Outlet: 20 [2000 psig (14 MPa)], Pressure Gauge Unit: psig/bar (or None in Case of no Gauge), Main Valve Seat Material: Vespel®, Standard, O-ring Material

Delivery Pressure: P [50 to 6000 psig (0.34 to 41.4 MPa)], Relieving: 1 (Self-relieving, Standard), Material: B (Brass), Ports: 4P (4 Ports), Connections: 4 (NPT 1/4 Inch), Gauge Port, Inlet: Q [10000 psig (70 MPa)], Gauge Port, Outlet: 60 [6000 psig (41 MPa)], Pressure Gauge Unit: psig/bar (or None in Case of no Gauge), Main Valve Seat Material: Vespel®, Standard, O-ring Material: VitonÂ

, 2" , NPN or PNP open collector, 1 output + analog , Flow rate (l/min): 150~3000, 300~6000, 600~12000, DIGITAL FLOW SW, INTEG SENSOR, INSTRUMENTATION, IF/PFA FLOW SWITCH, JB, IF/PFA 1 1/2 INCH NPT VERSION, 3.99153 lb, ModelMeasured fluidDetection typeRated flow range Note 1)Minimum set unit Note 1)Note 2)Display unitsOperating pressure rangeProof pressurePressure lossAccumulated

.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Weight (kg) 0.05 0.075 AC4000/5000/5500/6000 AR4000/5000/6000 AW4000 Applicable model C Part no.: 1305104-1A C1 Attachment: With cover ring assembly Part no.: 1305104-3A Note 1) Indicates the condition at the lower pressure limit.

PAT. 17-5-172 33 Flow Switch Series PF, IF For Air Digital Flow Switch/Series PFA Display integral type Output specification Port size (Rc, NPT, G) Flow rate range (l/min) Separate type Display Sensor Switch output Analog output Accumulated pulse output PFA710 750 711 721 751 703H 706H 712H PFA510 550 511 521 551 1 to 10 5 to 50 10 to 100 20 to 200 50 to 500 150 to 3000 300 to 6000 6000 to

Flow capacity (l/min (ANR)) Oil mist concentration at outlet side 300 750 1500 2200 3500 Filtration (m) Port size Rc Model AM150 AM250 AM350 AM450 AM550 1 8 1 4 3 8 1 4 3 8 1 2 3 8 1 2 3 4 Max. 1.0 mg/m3 (ANR) ( 0.8 ppm) , , , , , , , , , 1 1 0.3 1 2 3 4 3 4 1, 1 2 1 , 2 AM650 6000 AM850 12000 1 2 Can produce with auto drain type, drain piping type.

70C (Application of rated voltage) Temperature rise Power consumption DC Holding Inrush 5.6VA(50Hz), 5.0VA(60Hz) 12VA(50Hz), 10.5VA(60Hz) 3.4VA(50Hz), 2.3VA(60Hz) 7.5VA(50Hz), 6VA(60Hz) 1.8W 4.8W Apparent power AC Non-locking push style Others (Option) Manual override Non-locking push style 4.2-5 VNA Flow Characteristics Air How to Read The Graph In the sonic flow region: For a flow of 6000

, 2" , NPN or PNP open collector, 1 output + analog , Flow rate (l/min): 150~3000, 300~6000, 600~12000, DIGITAL FLOW SW, INTEG SENSOR, INSTRUMENTATION, IF/PFA FLOW SWITCH, JB, IF/PFA 1 1/2 INCH NPT VERSION, 4.23287 lb, ModelMeasured fluidDetection typeRated flow range Note 1)Minimum set unit Note 1)Note 2)Display unitsOperating pressure rangeProof pressurePressure lossAccumulated

Rated Flow Range: 06 (60 to 6000 l/min), Thread Type: N (NPT), Port Size: 14 (1 1/2), Output Specification: L4 [Out: IO-Link, Switch Output (N/P); Func: Analog Current Output <-> External Input; Monitor Unit Model: PFG310 Series], Lead Wire: Q (Lead Wire and M12-M12 Connector, 3m), Unit Specification: M (SI Unit Only), Calibration Certificate: A (Made to Order)

CY36 Consult with SMC in case a bracket with weight exceeding the above value is to be mounted. 28 27 26 25 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 1000 2000 3000 4000 5000 6000 CY315 Note 1) According to the dead weight deflection in the figure on the right, provide clearance so that the cylinder does not touch the mounting surface or the load, etc., and is able

For Air (Orifice diameter: 10 mm, 15 mm, 20 mm, 25 mm) How to read the graph The sonic range pressure to generate a flow rate of 6000 L/min (ANR) is as follows.

)/For AFF75A to AFF220A AFF75A AFF125A AD402-03-2 G46-15-02 AFF150A AFF220A Applicable model Auto drain (2 pcs. each) Pressure gauge (2 pcs. each) Companion flange (2 pcs. each) Anchor bolt (3 pcs. each) AI-2S 2BJIS 10KFF 3BJIS 10KFF 4BJIS 10KFF Model AFF2B AFF4B AFF8B AFF11B AFF22B AFF37B AFF75B AFF75A AFF125A AFF150A AFF220A Model Note) Rated flow (l/min (ANR)) 300 750 1500 2200 3500 6000

AMD150 AMD250 AMD350 AMD450 AMD550 AMD650 AMD850 Model Note) 200 500 1000 2000 3500 6000 12000 Rated flow (l /min (ANR)) Port size (Nominal size B) 1 8 1 4 3 8 1 4 3 8 1 2 3 8 1 2 3 4 1 1 2 3 4 1 3 4 1 1 1 2 1 2 1 2 , , , , , , , , , , , Weight (kg) 0.38 0.55 0.9 1.4 2.1 4.2 10.5 Note) Max. flow capacity at a pressure of 0.7 MPa. Max. flow varies depending on operating pressure.

AME150 AME250 AME350 AME450 AME550 AME650 AME850 Model Note) 200 500 1000 2000 3500 6000 12000 Rated flow (l/min (ANR)) Port size (Nominal size B) 1 8 1 4 3 8 1 4 3 8 1 2 3 8 1 2 3 4 1 1 2 3 4 1 3 4 1 1 1 2 1 2 1 2 , , , , , , , , , , , Weight (kg) 0.38 0.55 0.9 1.4 2.1 4.2 10.5 Note) Max. flow capacity at a pressure of 0.7 MPa. Max. flow varies depending on operating pressure.

AMF250 AMF350 AMF450 AMF550 AMF650 AMF850 AMF150 Model Note) 500 1000 2000 3500 6000 12000 200 Rated flow (l/min (ANR)) Port size (Nominal size B) , , , , , , , , , 1 8 1 4 3 8 1 4 3 8 1 2 3 8 1 2 3 4 1 1 2 3 4 1 3 4 1 1 1 2 1 2 1 2 , , 0.38 0.55 0.9 1.4 2.1 4.2 10.5 Weight (kg) Note) Max. flow capacity at a pressure of 0.7 MPa. Max. flow varies depending on operating pressure.

Model AMG150 AMG250 AMG350 AMG450 AMG550 AMG650 AMG850 Model Note) Rated flow (l /min (ANR)) 300 750 1500 2200 3500 6000 12000 Port size (Nominal size B) , , , , , , , , , , , 1 8 1 4 3 8 1 4 3 8 1 2 3 8 1 2 3 4 1 1 2 3 4 1 3 4 1 1 1 2 1 2 1 2 Weight (kg) 0.38 0.55 0.9 1.4 2.1 4.2 10.5 Note) Max. flow capacity at a pressure of 0.7 MPa. Max. flow varies depending on operating pressure.

AMH250 AMH350 AMH450 AMH550 AMH650 AMH850 AMH150 Model Note) 500 1000 2000 3500 6000 12000 200 Rated flow (l/min (ANR)) Port size (Nominal size B) 1 8 1 4 3 8 1 4 3 8 1 2 3 8 1 2 3 4 1 1 2 3 4 1 3 4 1 1 1 2 1 2 1 2 , , , , , , , , , , , 0.38 0.55 0.9 1.4 2.1 4.2 10.5 Weight (kg) Note) Max. flow capacity at pressure of 0.7 MPa. It varies depending on operating pressure.

Fan motor Outlet thermometer Model Selection (Flow Capacity l/min (ANR)) HAA7 HAA15 HAA22 HAA37 Model Outlet side air (COOL AIR) 50C 70C 100C 1000 1500 700 2200 4000 1500 3300 6000 2200 5700 13000 Inlet air temperature 4300 Cooling side air Cooler Conditions: Outlet temperature 40C, Ambient temperature 32C, Air pressure 0.7 MPa Drain 14-15-1 2 Series HAA How to Order Precautions 15 10 D 1

HA Accessory (Option) AT HAW2 HAW7 HAW22 HAW37 HAW55 HAW75 HAW110 Applicable model Screw flange (With companion flange) HAWF-141 HAWF-142 HAWF-200 HAWF-200 ID Auto-drain AD402-04 AD600-06 AD600-10 AMG Model Selection (Flow Capacity l/min (ANR)) AFF HAW2-04 HAW7-06 HAW22-14 HAW37-14 HAW55-20 HAW75-20 HAW110-30 Model 1000 70C 100C 180C 50C 2000 6000 12000 15000 22000 30 Inlet air temperature