SMC Corporation of America
Elite Part Number Search
Search Results "NCDGFN40-2100-A93"

Cooling Capacity: Cooling Capacity: 2100/2400W, 50/60 Hz, Cooling Method: Water-cooled Refrigeration, Thread: Rc, Option: B + T

Cooling Capacity: Cooling Capacity: 2100/2400W, 50/60 Hz, Cooling Method: Water-cooled Refrigeration, Thread: Rc, Option: Automatic Water Supply Function

Cooling Capacity: Cooling Capacity: 2100/2400W, 50/60 Hz, Cooling Method: Water-cooled Refrigeration, Thread: Rc, Option: J + M

Cooling Capacity: Cooling Capacity: 2100/2400W, 50/60 Hz, Cooling Method: Water-cooled Refrigeration, Thread: NPT w/PT-NPT Conversion Fitting Set, Option: Earth Leakage Breaker

Cooling Capacity: Cooling Capacity: 2100/2400W, 50/60 Hz, Cooling Method: Water-cooled Refrigeration, Thread: NPT w/PT-NPT Conversion Fitting Set, Option: B + J

Cooling Capacity: Cooling Capacity: 2100/2400W, 50/60 Hz, Cooling Method: Water-cooled Refrigeration, Thread: NPT w/PT-NPT Conversion Fitting Set, Option: B + M + T

Cooling Capacity: Cooling Capacity: 2100/2400W, 50/60 Hz, Cooling Method: Water-cooled Refrigeration, Thread: NPT w/PT-NPT Conversion Fitting Set, Option: B + J + T

Cooling Capacity: Cooling Capacity: 2100/2400W, 50/60 Hz, Cooling Method: Air-cooled Refrigeration, Thread: NPT w/PT-NPT Conversion Fitting Set, Option: J + M

Cooling Capacity: Cooling Capacity: 2100/2400W, 50/60 Hz, Cooling Method: Air-cooled Refrigeration, Thread: Rc, Option: G + J

Cooling Capacity: Cooling Capacity: 2100/2400W, 50/60 Hz, Cooling Method: Water-cooled Refrigeration, Thread: Rc, Option: M + T

Cooling Capacity: Cooling Capacity: 2100/2400W, 50/60 Hz, Cooling Method: Water-cooled Refrigeration, Thread: G w/PT-G Conversion Fitting Set, Option: M + T

Cooling Capacity: Cooling Capacity: 2100/2400W, 50/60 Hz, Cooling Method: Air-cooled Refrigeration, Thread: G w/PT-G Conversion Fitting Set, Option: M + T

Cooling Capacity: Cooling Capacity: 2100/2400W, 50/60 Hz, Cooling Method: Air-cooled Refrigeration, Thread: G w/PT-G Conversion Fitting Set, Option: J + M

Cooling Capacity: Cooling Capacity: 2100/2400W, 50/60 Hz, Cooling Method: Air-cooled Refrigeration, Thread: G w/PT-G Conversion Fitting Set, Option: G + T

Cooling Capacity: Cooling Capacity: 2100/2400W, 50/60 Hz, Cooling Method: Water-cooled Refrigeration, Thread: G w/PT-G Conversion Fitting Set, Option: M [Applicable to DI Water (Deionized Water) Piping]

Cooling Capacity: Cooling Capacity: 2100/2400W, 50/60 Hz, Cooling Method: Water-cooled Refrigeration, Thread: NPT w/PT-NPT Conversion Fitting Set, Option: Fixed SI Unit

2100 kHz ?1Voltage input (12 VDC or 24 VDC)10.8 to 13.2 VDC, 60 mAPreset output, Cylinder stop output, BCD outputCompare/Hold/One-shot (100 ms fixed pulse)Separate 5 point output/Binary code output5 ms or less (for normal output)RS-232CNPN open collector Max 30 VDC, 50 mA ?390 to 264 VAC20 VA or lessBetween case and AC line: 1500 VAC for 1 min.

2100 kHz ?1Voltage input (12 VDC or 24 VDC)10.8 to 13.2 VDC, 60 mAPreset output, Cylinder stop output, BCD outputCompare/Hold/One-shot (100 ms fixed pulse)Separate 5 point output/Binary code output5 ms or less (for normal output)RS-232CNPN open collector Max 30 VDC, 50 mA ?321.6 to 26.4 VDC10 W or lessBetween case and AC line: 1500 VAC for 1 min.

2100 kHz ?1Voltage input (12 VDC or 24 VDC)10.8 to 13.2 VDC, 60 mAPreset output, Cylinder stop outputCompare/Hold/One-shot (100 ms fixed pulse)Separate 5 point output/Binary code output5 ms or less (for normal output)RS-232CNPN open collector Max 30 VDC, 50 mA90 to 264 VAC20 VA or lessBetween case and AC line: 1500 VAC for 1 min.

2100 kHz ?1Voltage input (12 VDC or 24 VDC)10.8 to 13.2 VDC, 60 mAPreset output, Cylinder stop output, BCD outputCompare/Hold/One-shot (100 ms fixed pulse)Separate 5 point output/Binary code output5 ms or less (for normal output)RS-232CPNP open collector Max 30 VDC, 50 mA ?390 to 264 VAC20 VA or lessBetween case and AC line: 1500 VAC for 1 min.