Magnet: None, Mounting: E (Double End), Bore Size: 150 (1 1/2"), Stroke: 0100 (1"), Cushion: None, Auto Switch: None, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Temperature Option: XB6 (High Temperature), Stainless Steel Option: X6009 (All Stainless Steel)
Action Appiicable bore size air cylinder Double acting "'32,"'40, "'50 f6 63, .080,.0100 C95K1 Non-lube Specifications lMPa~1 0. 2kgflcm2 Bore size "'3~ r'''40 1 "'50 " )2>'6a I ,ii~o l %100 . ~ , I Action Double acting single rod Fluid Air Proof pressure 217 psi (15.3kgf/cml1) , Max. operating pressure 145 psi {10.2kgf/cm2 } t Min. opecsting pressure 7 pSI {0.5kgf/cm2} JIS Symbol Double
Magnet: None, Mounting: L (Foot), Cushion: N (Rubber Bumper), Bore Size: 32 (1 1/4"), Stroke: 0100 (1")
Magnet: None, Mounting: Foot, Cushion: Rubber Bumper, Bore Size: 1 1/4", Stroke: 1", Auto Switch: -, Lead Wire or Prewired Connector: -, Number: -
This is a legacy product. Please contact us for the latest version.sales@ocaire.com
This is a legacy product. Please contact us for the latest version.sales@ocaire.com
Magnet: None, Mounting: L (Axial Foot), Cushion: N (Urethane Cushion), Bore Size: 32mm, Stroke: 0100 (1"), Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Made to Order: XC6
Magnet: None, Mounting: L (Axial Foot), Cushion: N (Urethane Cushion), Bore Size: 32mm, Stroke: 0100 (1"), Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Made to Order: XC37
Magnet: None, Mounting: Axial Foot, Cushion: Urethane Cushion, Bore Size: 32mm, Stroke: 1", Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Made to Order: XC37
Magnet: None, Mounting: Axial Foot, Cushion: Urethane Cushion, Bore Size: 32mm, Stroke: 1", Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Made to Order: XC6
Mounting: L (Axial Foot Style), Cushion: N (Urethane Cushion), Bore Size: 32 (1 1/4"), Stroke: 1000 (10"), Temperature Resistant: XB6 [Heat Resistant, (-10 to150°C)]
Mounting: L (Axial Foot Style), Cushion: N (Urethane Cushion), Bore Size: 32 (1 1/4"), Stroke: 0500 (5"), Temperature Resistant: XB6 [Heat Resistant, (-10 to150°C)]
Mounting: Axial Foot Style, Cushion: Urethane Cushion, Bore Size: 1 1/4", Stroke: 10", Temperature Resistant: XB6 [Heat Resistant, (-10 to150°C)]
Magnet: None, Mounting: Foot, Cushion: Rubber Bumper, Bore Size: 1 1/4", Stroke A: 1 1/2", +: +, Stroke B: 1", Stroke Adjustment: None, Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Stroke Options: Dual Stroke, Single Rod
Range Setting Enabled Section 2 Output Signal Selection 1 0 to 3 0 After restart Setup Pn50E 2 Output Signal Selection 2 0 to 3 0100 After restart Setup Pn50F 10-19 10 List of Parameters (contd) Parameter Name Setting Units Factory When Classification Profile Reference Size No.
Modbus RTU protocol (Hexadecimal notation) Request data 01 08 0 1234 ED7C Response data (normal response) 01 08 0 1234 ED7C (Binary notation) Response data 0001 1000 0 0 0001 0010 0011 0100 1110 1101 0111 1100 Response data (normal response) 0001 1000 0 0 0001 0010 0011 0100 1110 1101 0111 1100 For correspondence between ASCII notation and ASCII hexadecimal notation, refer to the 8.4 ASCII
-XAl Change of rod end shape -XB6 Heat resistant cylinder (10 to 150C) * Not available with switch & with air cushion VMounted on the product. vPlease order separately.
Example 1) ASCII mode Received function code: 04(0 0100)ASCII code 30h34h Abnormal function code: 84(1000 0100)ASCII code 38h34h Example 2) RTU mode Received function code:04 (0 0100) Abnormal function code:84 (1000 0100) 2) Error Code Assign error code below. 01: Function code of a command is outside the standard. 02: The specified address of register is outside the range. 03: Data field
Example 1) ASCII mode Received function code: 04(0 0100) ASCII code 30h, 34h Abnormal function code: 841000 0100 ASCII code 38h, 34h Example 2) RTU mode Receive function code: "04" (0 0100) Abnormal function code: "84" (1000 0100 2) Error Code Assign error code below. 01 : Function code of a command is outside the standard 02 : The specified address of register is outside the range. 03 :