This is a legacy product. Please contact us for the latest version.sales@ocaire.com
This is a legacy product. Please contact us for the latest version.sales@ocaire.com
SMC's new PFMB dual color digital flow switch allows for a wide range of flow measurement with one product. The PFMB is suitable for use with air and nitrogen. It's compact and space saving with an integrated flow adjustment valve. The bypass structure limits the contact of moist air with the sensor, reducing degradation of the sensor and helps maintain accuracy. 2-color display improves
Type: Fan Type, Indicator: Charged/Discharged Status / Cleaning / Error, Additional Function: Air Volume Adjustment / Error Signal Output, Air Flow/Consumption Amount(m3/min): 1.8, Ion Balance: ±5V, Ion Balance Adjusting Function: Manual, Operating Pressure Range(MPa): -, Power Supply: DC24V, Options: -, Accessories/options: ordered separately: With power supply cable (3 m) / With
Model: 4.4 m³/min, Input/Output: NPN, Input/Output, Power Supply Cable, AC Adapter: w/Power Supply Cable, 3m, Bracket: w/Bracket, Automatic Cleaning Unit, Louver: w/Adjustable Louver, Filter: -
Model: 31 (4.4 m³/min), Input/Output: NPN, Input/Output, Power Supply Cable, AC Adapter: w/Power Supply Cable, 3m, Bracket: B (w/Bracket), Automatic Cleaning Unit, Louver: W (w/Adjustable Louver)
Model: 21 (1.8 m³/min), Input/Output: NPN, Input/Output, Power Supply Cable, AC Adapter: w/Power Supply Cable, 3m, Bracket: B (w/Bracket), Automatic Cleaning Unit, Louver: W (w/Adjustable Louver)
Flow Adjustment Valve: With Valve, Port Size: Ø8 (5/16") One-touch Fitting, Piping Entry Direction: Straight, Output Specifications: NPN, Analog 1 to 5 V, Option 1: w/Lead Wire w/Connector, Unit Specifications: SI Unit Only, Option 2: With Panel Mount Adapter, Calibration Certificate: -
Flow Adjustment Valve: With Valve, Port Size: NPT1/4, Piping Entry Direction: Bottom, Output Specifications: PNP, PNP, Option 1: w/Lead Wire w/Connector, Unit Specifications: SI Unit Only, Option 2: With Panel Mount Adapter, Calibration Certificate: -
Flow Adjustment Valve: With Valve, Port Size: NPT1/4, Piping Entry Direction: Straight, Output Specifications: NPN, NPN, Option 1: w/Lead Wire w/Connector + Connector Cover, Unit Specifications: SI Unit Only, Option 2: With Panel Mount Adapter, Calibration Certificate: -
Flow Adjustment Valve: With Valve, Port Size: NPT1/4, Piping Entry Direction: Straight, Output Specifications: NPN, Analog 1 to 5 V, Option 1: w/Lead Wire w/Connector + Connector Cover, Unit Specifications: SI Unit Only, Option 2: With Panel Mount Adapter, Calibration Certificate: -
Flow Adjustment Valve: With Valve, Port Size: Ø8 (5/16") One-touch Fitting, Piping Entry Direction: Bottom, Output Specifications: NPN, Analog 1 to 5 V, Option 1: No Lead Wire, Unit Specifications: SI Unit Only, Option 2: With Panel Mount Adapter, Calibration Certificate: -
Flow Adjustment Valve: With Valve, Port Size: Ø8 (5/16") One-touch Fitting, Piping Entry Direction: Bottom, Output Specifications: PNP, Analog 1 to 5 V, Option 1: w/Lead Wire w/Connector + Connector Cover, Unit Specifications: SI Unit Only, Option 2: With Panel Mount Adapter, Calibration Certificate: -
Flow Adjustment Valve: With Valve, Port Size: NPT1/4, Piping Entry Direction: Straight, Output Specifications: PNP, Analog 1 to 5 V, Option 1: w/Lead Wire w/Connector, Unit Specifications: SI Unit Only, Option 2: With Panel Mount Adapter, Calibration Certificate: -
Flow Adjustment Valve: With Valve, Port Size: NPT1/4, Piping Entry Direction: Bottom, Output Specifications: NPN, Analog 1 to 5 V, Option 1: w/Lead Wire w/Connector + Connector Cover, Unit Specifications: SI Unit Only, Option 2: With Panel Mount Adapter, Calibration Certificate: -
Flow Adjustment Valve: With Valve, Port Size: Ø8 (5/16") One-touch Fitting, Piping Entry Direction: Bottom, Output Specifications: NPN, NPN, Option 1: w/Lead Wire w/Connector, Unit Specifications: SI Unit Only, Option 2: With Panel Mount Adapter, Calibration Certificate: -
Flow Adjustment Valve: With Valve, Port Size: NPT1/4, Piping Entry Direction: Straight, Output Specifications: PNP, Analog 4 to 20 mA, Option 1: w/Lead Wire w/Connector, Unit Specifications: SI Unit Only, Option 2: With Panel Mount Adapter, Calibration Certificate: -
Rated Flow Range: 21 (2 to 200 L/min), Flow Adjustment Valve: W (With Flow Adjustment Valve, Rear Ported), Port Size: C8 (ø8), Output Specification: E (Out 1: PNP; Out 2: Analog 1 to 5 V - Analog 0 to 10 V), Lead Wire: W (Lead Wire w/Connector + Rubber Cover for Connector), Unit Specification: M (SI Unit Only), Bracket/Panel Mount Adapter: V (Panel Mount Adapter, w/Flow Adjustment Valve)
Rated Flow Range: 21 (2 to 200 L/min), Flow Adjustment Valve: W (With Flow Adjustment Valve, Rear Ported), Port Size: N2 (NPT1/4), Output Specification: C (Out 1: NPN; Out 2: Analog 1 to 5 V - Analog 0 to 10 V), Lead Wire: W (Lead Wire w/Connector + Rubber Cover for Connector), Unit Specification: M (SI Unit Only), Bracket/Panel Mount Adapter: V (Panel Mount Adapter, w/Flow Adjustment Valve
Rated Flow Range: 10 (0.1 to 10 L/min), Flow Adjustment Valve: W (With Flow Adjustment Valve, Rear Ported), Port Size: N1 (NPT1/8), Output Specification: C (Out 1: NPN; Out 2: Analog 1 to 5 V - Analog 0 to 10 V), Lead Wire: W (Lead Wire w/Connector + Rubber Cover for Connector), Unit Specification: M (SI Unit Only), Bracket/Panel Mount Adapter: V (Panel Mount Adapter, w/Flow Adjustment Valve