Rated Flow Range: 40 (5 to 40 L/min), Flow Adjustment Valve: S (Flow Adjustment Valve), Thread: F (G), Port Size: 06 (3/4), Output Specification: 1 (OUT1: Analog 1 to 5V), Temperature Sensor: T (OUT2: Analog 1 to 5V, w/Temperature Sensor)
Rated Flow Range: 5 to 40 L/min, Flow Adjustment Valve: Flow Adjustment Valve, Thread: G, Port Size: 3/4, Output Specification: OUT1: Analog 1 to 5V, Temperature Sensor: OUT2: Analog 1 to 5V, w/Temperature Sensor, Lead Wire: -, Units on Label: -, Bracket: -, Calibration Certificate: -, Made to Order: -
Vacuum Pressure Switch (Series ZS), Vacuum Pressure Gauge (Series GZ) Timing Chart Example During vacuum release During adsorption When adsorbing and transferring a workpiece, verify at the vacuum pressure switch as much as possible (In addition, visually verify the vacuum gauge, especially when handling a heavy or a hazardous item.).
Vacuum Pressure Switch (Series ZS), Vacuum Pressure Gauge (Series GZ) Timing Chart Example During vacuum release During adsorption When adsorbing and transferring a workpiece, verify at the vacuum pressure switch as much as possible (In addition, visually verify the vacuum gauge, especially when handling a heavy or a hazardous item.).
(full span), GAUGE, VACUUM SERIES, GZ VACUUM GAUGE, JC, GZ 1/8 PORTED, 0.49983 lb
GZ VACUUM GAUGE GZ 1/4 PORTED
Please contact us for the latest version.sales@ocaire.com, GAUGE, VACUUM SERIES, GZ VACUUM GAUGE, JC, GZ 1/8 PORTED, 0.11 lb
Please contact us for the latest version.sales@ocaire.com, GAUGE, VACUUM SERIES, GZ VACUUM GAUGE, JD, GZ 1/8 PORTED, 0.11 lb
Surge voltage suppressor DIN terminal Grommet, L/M plug connector With indicator light GZ LZ,LOZ,MZ,MOZ With surge voltage suppresser (DS) Coil Coil Varistor Coil Coil Varistor With light/surge voltage suppresser (DZ) Non-polar type (U) (-) (+) Coil Varistor (+) (-) Varistor DIN terminal has no polarity.
Please contact us for the latest version.sales@ocaire.com, GAUGE, VACUUM SERIES, GZ VACUUM GAUGE, JD, GZ 1/8 PORTED, 0.36863 lb
Please contact us for the latest version.sales@ocaire.com, GAUGE, VAC, 1/8 PT, VACUUM SERIES, GZ VACUUM GAUGE, JC, GZ 1/8 PORTED, .26655 lb
(full span), GZ 1/8 PORTED, VACUUM SERIES, GZ 1/8 PORTED, 0.20544 lb
Rated Flow Range: 40 (5 to 40 L/min), Flow Adjustment Valve: None, Thread: F (G), Port Size: 06 (3/4), Output Specification: 1 (OUT1: Analog 1 to 5V), Temperature Sensor: None, Lead Wire: Lead Wire w/M8 Connector, 3m, Units on Label: Instantaneous Flow Rate: L/min; Accumulated Flow: L; Temp: °C, Bracket: None, Calibration Certificate: None, Made to Order: X109 (EPDM Seal Material)
Rated Flow Range: 40 (5 to 40 L/min), Flow Adjustment Valve: None, Thread: F (G), Port Size: 06 (3/4), Output Specification: 2 (OUT1: Analog 4 to 20mA), Temperature Sensor: None, Lead Wire: Lead Wire w/M8 Connector, 3m, Units on Label: Instantaneous Flow Rate: L/min; Accumulated Flow: L; Temp: °C, Bracket: None, Calibration Certificate: A (Calibration Certificate)
Rated Flow Range: 40 (5 to 40 L/min), Flow Adjustment Valve: None, Thread: F (G), Port Size: 06 (3/4), Output Specification: 1 (OUT1: Analog 1 to 5V), Temperature Sensor: None, Lead Wire: N (w/o Lead Wire w/M8 Connector), Units on Label: Instantaneous Flow Rate: L/min; Accumulated Flow: L; Temp: °C, Bracket: None, Calibration Certificate: None, Made to Order: X109 (EPDM Seal Material)
Rated Flow Range: 5 to 40 L/min, Flow Adjustment Valve: None, Thread: G, Port Size: 3/4, Output Specification: OUT1: Analog 4 to 20mA, Temperature Sensor: None, Lead Wire: Lead Wire w/M8 Connector, 3m, Units on Label: Instantaneous Flow Rate: L/min; Accumulated Flow: L; Temp: °C, Bracket: None, Calibration Certificate: Calibration Certificate, Made to Order: -
Rated Flow Range: 5 to 40 L/min, Flow Adjustment Valve: None, Thread: G, Port Size: 3/4, Output Specification: OUT1: Analog 1 to 5V, Temperature Sensor: None, Lead Wire: Lead Wire w/M8 Connector, 3m, Units on Label: Instantaneous Flow Rate: L/min; Accumulated Flow: L; Temp: °C, Bracket: None, Calibration Certificate: None, Made to Order: EPDM Seal Material
Rated Flow Range: 5 to 40 L/min, Flow Adjustment Valve: None, Thread: G, Port Size: 3/4, Output Specification: OUT1: Analog 1 to 5V, Temperature Sensor: None, Lead Wire: w/o Lead Wire w/M8 Connector, Units on Label: Instantaneous Flow Rate: L/min; Accumulated Flow: L; Temp: °C, Bracket: None, Calibration Certificate: None, Made to Order: EPDM Seal Material
CS1-F16 CS1-F14 CS1-F12 CA-F05 CA-F10 CA-F04 CA-F08 DBD1-04M BD1-05M BD1-06M BD1-08M BD1-10M BS1-125 BS1-140 BS1-160 CA1-F06 CS1-F16 CS1-F14 CS1-F12 CA1-F05 CA1-F10 CA1-F04 CA1-F08 Head side flange style CA1-C06 CS1-C16 CS1-C14 CS1-C12 CA1-C05 CA1-C10 CA1-C04 CA1-C08 Single clevis -X BA-04 BA-05 BA-06 BA-08 BA-10 Double clevis CA1-D06 CS1-D16 CS1-D14 CS1-D12 CA1-D05 CA1-D10 CA1-D04 CA1-
Bore size [mm] 40 50 63 80 100 Axial foot* CA2-L04 CA2-L05 CA2-L06 CA2-L08 CA2-L10 Flange CA2-F04 CA2-F05 CA2-F06 CA2-F08 CA2-F10 Caution 1. The minimum stroke for mounting varies with the auto switch type and cylinder mounting type. In particular, the center trunnion type needs careful attention.