Rated Flow Range: 40 (5 to 40 L/min), Flow Adjustment Valve: None, Thread: Rc, Port Size: 04 (1/2), Output Specification: 1 (OUT1: Analog 1 to 5V), Temperature Sensor: T (OUT2: Analog 1 to 5V, w/Temperature Sensor)
Rated Flow Range: 40 (5 to 40 L/min), Flow Adjustment Valve: None, Thread: Rc, Port Size: 06 (3/4), Output Specification: 1 (OUT1: Analog 1 to 5V), Temperature Sensor: T (OUT2: Analog 1 to 5V, w/Temperature Sensor)
Rated Flow Range: 40 (5 to 40 L/min), Flow Adjustment Valve: None, Thread: F (G), Port Size: 04 (1/2), Output Specification: 1 (OUT1: Analog 1 to 5V), Temperature Sensor: T (OUT2: Analog 1 to 5V, w/Temperature Sensor)
Rated Flow Range: 5 to 40 L/min, Flow Adjustment Valve: None, Thread: NPT, Port Size: 3/4, Output Specification: OUT1: Analog 1 to 5V, Temperature Sensor: OUT2: Analog 1 to 5V, w/Temperature Sensor, Lead Wire: -, Units on Label: -, Bracket: -, Calibration Certificate: -, Made to Order: -
Rated Flow Range: 5 to 40 L/min, Flow Adjustment Valve: None, Thread: G, Port Size: 3/4, Output Specification: OUT1: Analog 1 to 5V, Temperature Sensor: OUT2: Analog 1 to 5V, w/Temperature Sensor, Lead Wire: -, Units on Label: -, Bracket: -, Calibration Certificate: -, Made to Order: -
Rated Flow Range: 5 to 40 L/min, Flow Adjustment Valve: None, Thread: Rc, Port Size: 1/2, Output Specification: OUT1: Analog 1 to 5V, Temperature Sensor: OUT2: Analog 1 to 5V, w/Temperature Sensor, Lead Wire: -, Units on Label: -, Bracket: -, Calibration Certificate: -, Made to Order: -
Rated Flow Range: 5 to 40 L/min, Flow Adjustment Valve: None, Thread: Rc, Port Size: 3/4, Output Specification: OUT1: Analog 1 to 5V, Temperature Sensor: OUT2: Analog 1 to 5V, w/Temperature Sensor, Lead Wire: -, Units on Label: -, Bracket: -, Calibration Certificate: -, Made to Order: -
Rated Flow Range: 5 to 40 L/min, Flow Adjustment Valve: None, Thread: G, Port Size: 1/2, Output Specification: OUT1: Analog 1 to 5V, Temperature Sensor: OUT2: Analog 1 to 5V, w/Temperature Sensor, Lead Wire: -, Units on Label: -, Bracket: -, Calibration Certificate: -, Made to Order: -
Add 10 g for conduit type, 30 g for DIN terminal type, 60 g for conduit terminal type respectively.
PF2W520 PF3W520 PF2W540 PF3W540 PF2W511 PF3W511 PF2W504 PF3W504 Function selection mode Safety Instructions Other functions Sensor connector Mounting and Installation PF2D2 series Lever Warning Installation or Channel scan function Peak / Bottom value display Key-lock function PF2D520 PF2D540 PF2D504 Do not disassemble, modify (including changing the printed circuit board) or repair.
Speed Controller/In-line Type AS2000-N02-X800/AS3000-N03-X800/AS4000-N04-X800 P .G. information Point to Group Specialized Product Flow Characteristics AS3000-N03-X800 AS4000-N04-X800 AS2000-N02-X800 300 800 Flow rate L/min (ANR) Flow rate L/min (ANR) Flow rate L/min (ANR) 1500 250 600 200 1000 150 400 100 500 200 50 0 0 1 2 3 4 5 6 7 9 8 10 0 0 1 2 3 4 5 6 7 9 8 0 0 1 2 3 4 5 6 7 8 Number
f21 n. g!4) 31t1 l,loB thln 8 rtrtlo.n @itact tctoP. DritENsroNs A B c D E F G H J K lul N o P R s T u 3.43 (84 2.43 (72) 1.89 (48) 2.61 {67) 3.54 {so) 1.73 (44) 1.81 (46) 3.54 (90) 1.97 (s0) 0.79 (20) 0.35 (91 5.12 (130) 4.
H 2 position double: VQ525 3 position closed center: VQ535 3 position exhaust center: VQ545 3 position pressure center: VQ555 3 position double check: VQ565 0 1 0 1 0 1 0 1 G H G H G H G H 194.5 (200) 121.3 53 73.2 (78.7) Indicator light 213 121.3 91.5 13.5 (Port B) 59.5 53 (Port A)17.5 13.5 (Port B) 59.5 (Port A) 17.5 Indicator light SMC 2 4 2 4 SMC A B A B 53 40 66 162 50 41 37 31.5 18
H 2 position double: VQ525 3 position closed center: VQ535 3 position exhaust center: VQ545 3 position pressure center: VQ555 3 position double check: VQ565 0 1 0 1 0 1 0 1 G H G H G H G H 194.5 (200) 121.3 53 73.2 (78.7) Indicator light 213 121.3 91.5 13.5 (Port B) 59.5 53 (Port A)17.5 13.5 (Port B) 59.5 (Port A) 17.5 Indicator light SMC 2 4 2 4 SMC A B A B 53 40 66 162 50 41 37 31.5 18
N01 Connection NPT 1/8 N02 Connection NPT 1/4 Port size N03 Connection NPT 3/8 Option specifications Application Size Symbol N04 Connection NPT 1/2 IRV3000 IRV2000 IRV1000 F01 Connection G 1/8 01 02 03 04 1/8 1/4 3/8 1/2 F02 Connection G 1/4 F03 Connection G 3/8 F04 Connection G 1/2 Accessory (Option) Part No. Part no.
\ ZL3: 390 g ZL6 Max. 60% reduction*3 Suction: 100 L ZL1 Silencer Pressure switch for vacuum with energy saving function *3 ZL112 (Existing model): 450 g \ ZL1: 180 g Max. suction flow rate: 300 L/min (ANR) ZL3 Series Max. suction flow rate: 100 L/min (ANR) ZL1 Series Series Vacuum pressure [kPa] Max. suction flow rate [L/min (ANR)] Air consumption [L/min (ANR)] Weight*6 [g] Page ZL1 84 100
N06 NPT3/4 5/16(inch) N04 2xNPT1/2 6) 5 DC24V *1G JIS B0202 ISO1603 ISO1179 8) Z 7 L L 0.3(m) 11) A NPN LO B PNP M M 0.3(m) MO 12) 9) M SI (kPa) D P (:psi) E 10) 14 GN (G) B G *7ZL212 27mm ZL212 (2 /1 , 4 ) E (2 ) F (2 ) V (1 ) 13 G 2m) W (2m) 5 No.ZL3-OM00801-A 2. 2.1 (1/P) (2/V) ZL3 ZL6 (3/E) // / (G) (2/V) 2.2 ZL6 1 ZL6 (ZL6-SC1-A) 2), 6 No.ZL3-OM00801-A 3. 3.1
Port size 10 8 6 12 1/8" 1/4" 3/8" 5/32" 3/16" 5/16" 4 ASD230F-M5 ASD330F-01 ASD430F-02 ASD530F-02 ASD530F-03 ASD630F-04 M5 x 0.8 R 1/8 R 1/4 R 1/4 R 3/8 R 1/2 ASD230F-U10/32 ASD330F-N01 ASD430F-N02 ASD530F-N02 ASD530F-N03 ASD630F-N04 10-32 UNF NPT 1/8 NPT 1/4 NPT 1/4 NPT 3/8 NPT 1/2 Specifications Fluid Air Proof pressure 1.5 MPa Max. operating pressure 1 MPa Min. operating pressure
Metric Inch Model Port size 6 8 10 12 1/8" 5/32" 3/16" 1/4" 5/16" 3/8" 4 ASD230F-M5 ASD330F-01 ASD430F-02 ASD530F-02 ASD530F-03 ASD630F-04 M5 X 0.8 R(PT)1/8 R(PT)1/4 R(PT)1/4 R(PT)3/8 R(PT)1/2 ASD230F-U10/32 ASD330F-N01 ASD430F-N02 ASD530F-N02 ASD530F-N03 ASD630F-N04 10-32 UNF NPT1/8 NPT1/4 NPT1/4 NPT3/8 NPT1/2 Specifications Proof pressure 1.5MPa Max. operating pressure 1MPa JIS symbol
Rated Flow Range: 40 (5 to 40 L/min), Flow Adjustment Valve: w/o Flow Adjustment Valve, Thread: F (G), Port Size: 06 (3/4), Output Specification/Temperature Sensor: 1T (Out 1 Flow Rate: Analog 1 to 5 V; Out 2 Temperature: Analog 1 to 5 V; Temperature Sensor: w/Temperature Sensor), Lead Wire: w/Lead Wire and M8 Connector, 3 m, Unit Specification: G [Instantaneous Flow: L/min (gal/min), Temperature