In the case of complex arrangement, specify them on the manifold specification sheet. 53 42 SS5Y 05 5 02 Manifold series Stations 5 7 02 53-SY5000 2 stations 53-SY7000 20 20 stations Thread type A, B port size Nil F N T Rc Thread piping G Symbol Port size Applicable series NPT 1/4 53-SY5000 53-SY7000 02 NPTF Warning If a resin tubing is used, take precautions against static electricity.

ASR430F-02-08S(-F20) ASR430F-02-10S(-F20) ASR530F-02-06S(-F20) ASR530F-02-08S(-F20) ASR530F-02-10S(-F20) ASR530F-02-12S(-F20) ASR530F-03-06S(-F20) ASR530F-03-08S(-F20) ASR530F-03-10S(-F20) ASR530F-03-12S(-F20) ASR630F-03-10S(-F20) ASR630F-03-12S(-F20) ASR630F-04-10S(-F20) ASR630F-04-12S(-F20) ASQ430F-02-06S(-F20) ASQ430F-02-08S(-F20) ASQ430F-02-10S(-F20) ASQ530F-02-06S(-F20) ASQ530F-02-08S

Table 3-12 Piping port size Name Port size1 Recommended Recommended piping tightening torque specification Circulating fluid outlet port Rc3/4 28 to 30Nm 1.0MPa and more Circulating fluid return port Rc3/4 28 to 30Nm 1.0MPa and more Facility water inlet port*1 Rc3/4 28 to 30Nm 1.0MPa and more.

2PW Delivery pressure Bonnet option Delivery pressure 1 to 30 psig (0.007 to 0.2 MPa) 2 to 60 psig (0.014 to 0.4 MPa) 2 to 100 psig (0.014 to 0.7 MPa) 5 to 150 psig (0.034 to 1.0 MPa) Code Bonnet Standard Panel installation 4) Code 02 06 10 15 No code P Connections (Inletq, Outletw) 4) Panel mounting hole: dia. 1.56 inch (39.6 mm).

Max. 10 16.1 46.2 M8 x 1 31.1 36 18.5 42.6 [49.6] Approx. 300 (Lead wire length) Pg7 80.5 [82.7] 70.7 [72.9] 90.5 89.6 72.2 65.7 49.7 23.5 10.9 23.5 10.9 23.5 10.9 23.5 10.9 21 21 21 21 25 25 25 25 2 x 3.2 (For mounting) 2 x 3.2 (For mounting) 2 x 3.2 (For mounting) 2 x 3.2 (For mounting) 28 28 28 28 Refer to page 646 for dimensions with connector cable. 630 3 Port Pilot Solenoid Valve

Pivot Bracket Pivot Bracket Pin (For CM2C) Pivot brackets consists of a set of two brackets. 7.5 40 7.5 40 3.4 3.4 6.8 6.8 R3.4 R3.4 6.8 6.8 25 25 R3.4 R3.4 Dd9 d 0.2 17 0.2 17 R11 R11 m m L2 +0.15 +0.05 +0.15 +0.05 CD CD t L1 t 5.2 40 5.2 40 3.2 3.2 57 28 57 28 (mm) (mm) Applicable bore size Part no.

connector 51 22 9.5 18 18 1/4 (Piping port) 28 269 Single Unit/Sub-plate Type 10-SV Dimensions: Series 10-SV3000 2 position single/double [M12 waterproof connector type] 10-SV300(R)-W-02, 03 Directional Control Valves Air Grippers Modular F.

L7 L6 L5 1021-VV5Q11 (L1) 28 (n-1) x 10.5 1.5 A FG + + 0V 24V SMC S E R I A L U N I T MODEL SC (SI No.EX120-STA1) 2 93.5 66 64 ERR T/R RUN 0 1 DIP SW. Drawing shows a SC case.

L7 L6 L5 1021-VV5Q11 (L1) 28 (n-1) x 10.5 1.5 A FG + + 0V 24V SMC S E R I A L U N I T MODEL SC (SI No.EX120-STA1) 2 93.5 66 64 ERR T/R RUN 0 1 DIP SW. Drawing shows a SC case.

AS3001F-08 AN101-01 AN101-01 T1075 x 1 m T0604 x 1 m T0604 x 1 m T1209 x 1 m T1075 x 1 m AS4001F-10 SY7120-02 SY7140-03 AS3001F-06 AS4001F-10 AS3001F-06 AN110-01 AN200-02 T0604 x 1 m T1075 x 1 m T1209 x 1 m T0604 x 1 m T1075 x 1 m T1209 x 1 m AS3001F-06 AS4001F-10 AS4001F-12 SY9120-03 SY9140-04 AS3001F-06 AS4001F-10 AS4001F-12 AN202-02 AN200-02 AN200-02 Conditions [When using SGP (steel

16 SMC 9 9 9 VP7 2-PE port M5 X 0.8 (Not applicable to standard.) 18 18 2.1 5-Rc(PT)1/8,1/4 (P, A, B, R1, R2 port) 2.1 VP4 28 M5 X 0.8 External pilot port (Only external pilot style(R)) VQ 0 1 01 02 L plug connector (L): VQZ225 (R)lLl 0 1 01 02 DIN connector (Y): VQZ225 (R)lYl VQ4 Indicator light VQZ 300 135<137> (Lead wire length) 67.5<68.5> VQD VZS Applicable cord O.D.

AS2201F-01-06-X214 AS2301F-01-06-X214 RS H A AS2201F-01-06-X214 AS2301F-01-06-X214 AS2201F-02-06-X214 AS2301F-02-06-X214 RZQ 3. When disassembling to replace the seals and wear ring, refer to the separate disassembly instructions. AS3201F-02-08-X214 AS3301F-02-08-X214 AS3201F-02-08-X214 AS3301F-02-08-X214 MI W S 4.

AS2201F-01-06-X214 AS2301F-01-06-X214 RS H A AS2201F-01-06-X214 AS2301F-01-06-X214 AS2201F-02-06-X214 AS2301F-02-06-X214 RZQ 3. When disassembling to replace the seals and wear ring, refer to the separate disassembly instructions. AS3201F-02-08-X214 AS3301F-02-08-X214 AS3201F-02-08-X214 AS3301F-02-08-X214 MI W S 4.

Dimension L 21 273 22 285.5 23 298 24 310.5 25 323 26 335.5 27 348 28 360.5 29 373 30 385.5 No. Dimension L 31 398 32 410.5 33 423 34 435.5 35 448 36 460.5 37 473 38 485.5 39 498 40 510.5 50 Series SQ1000/2000 Manifold Options for SQ1000/SQ2000 Negative COM specifications The following valve part numbers are for negative COM specifications.

Snap rings (2) PC-01 PC-02 PC-03 PC-03 PC-05 Snap rings (2) PC-01 PC-02 PC-03 PC-03 PC-05 Clevis (1) RCS-015 RCS-02 RCS-03 RCS-04 RCS-05 Pin (1) PS-015 PS-02 PS-03 PS-03 PS-05 Clevis (1) RCD-015 RCD-02 RCD-03 RCD-04 RCD-05 Pin (1) PS-015 PS-02 PS-03 PS-03 PS-05 056 (9/16") 075 (3/4") 106 (1-1/16") 150 (1-1/2") 200 (2"), 250 (2-1/2") 056 (9/16") 075 (3/4") 106 (1-1/16") 150 (1-1/2") 200 (2

(Supply puressure: 0.3 to 0.5 MPa) Facility water outlet port *1 Rc1 36 to 38Nm 1.0 MPa or more Automatic fluid fill port Rc3/8 28 to 30Nm (Automatic fluid fill pressure: 0.2 to 0.5 MPa Overflow port Rc1 36 to 38Nm ID 25 mm or more Length 5m or less Tank drain port Rc3/4 28 to 30Nm ID 19 mm or more *1: Water cooled type only.

Model VQZ100 VQZ200 VQZ300 AN110-01 AN200-02 AN200-02 AN200-02 AN110-01 Port plug VVQZ100-CP (For VQZ100) This is used when changing piping location.

Valve mounting direction ( ) 02 2 stations Single solenoid coil is located on the opposite side of the A, B port. -: : Single solenoid coil is located on same side as the A, B port.

-04 (S) 4 7.2 9.6 12 1/8 13 (12.7) ASN AQ 24 AS231FS1-02-06 (S) 6 11.2 19 33.8 21.4 43.9 14.2 26 AS231FS1-02-08 (S) 8 13.2 34.9 23.5 46 15.6 27 AS231FS1-02-10 (S) 10 15.9 20.9 38.1 24.7 47.3 17 28 AS331FS1-02-06 (S) 6 8.2 16.5 29.9 17.5 40.1 13.3 1/4 17 (17.5) 12.9 13 49.7 48.3 44.2 42.8 21.5 16.2 ASV 49 AS331FS1-02-08 (S) 8 13.2 37.1 23.5 59.9 14.2 50 AS331FS1-02-10 (S) 10 15.9 17.4 23 41.2

(W0): SYJ3240-W0-M5 M plug connector (M): SYJ3240-M-M5 Approx. 300 (Lead wire length) 41.5 [48.5] 26.1 46 M8 x 1 28.5 52.6 [59.6] Approx. 300 (Lead wire length) 98.6[103] 79 [83.4] R1 P R2 R1 P R2 R1 P R2 10 10 10 10 10 10 96.8 28 28 69 28 82 14 14 14 5 5 5 Refer to the page 91 for dimentions with connector cable. 9 Series SYJ3000 3 Position Closed Center/Exhaust Center/Pressure Center