SMC Corporation of America
Elite Part Number Search
Search Results "RDLQD50TN-50M-F-M9BL"

Developed to be combined with our extensive line of fittings, the addition of the TILM tube provides a complete solution for your piping equipment needs., FLUOROPOLYMER,TUBING NAT 50M, TUBING, FLUORO. TL/TIL, TD/TID, TH/TIH, H09, 9.64 lb

Size, Body, Valve Type: 50M (Size: 2; Body Mat'l: Resin; Port Size ø10 One-touch Fitting; Orifice Dia: 7, N.O.), Voltage and Electrical Entry: F (24VDC; Grommet w/Surge Voltage Suppressor)

If the variable orifice is closed (turn the adjustment knob counterclockwise), all LED's are off. d When opening the variable orifice (turn the adjustment knob clockwise) the LED's will light up in the following order: Red 1, Red 2, Green 1, Green 2 f When the LED Green 1 is on, the output is energized.

Set value correction by auto shift function Supply pressure normal Supply pressure drop Supply pressure increase F Reset function P-1 C-5 C-5 (P-3) (Differential) Pressure This function clears and resets the zero value on the display of measured (differential) pressure within 7%F.S. of the factory adjusted value.

SW RESET RUN2 RUN1 OV INPUT 6 7 5 8 4 + 9 3 SET UP A 2 B 1 0 C D 1 E F 0 to 10V V R 1 OUTPUT SET UP BALANCE CONTROLLER VYU5-D 2 V R 2 OV ERR.

(Example) D-Y7NWL Impact resistance . 1,000m/s (102G) Insulation resistance . 50M or more at 500VDC (between lead wire and case) Withstand voltage . 1000VAC for 1 min. (between lead wire and case) Ambient temperature ... 10 to 60C (14 to 140F) Enclosure .

(Example) D-Y7NWL Impact resistance . 1,000m/s (102G) Insulation resistance . 50M or more at 500VDC (between lead wire and case) Withstand voltage . 1000VAC for 1 min. (between lead wire and case) Ambient temperature ... 10 to 60C (14 to 140F) Enclosure .

Install a filter strainer of about 50m on the inlet side of the piping. 4. Preparation before piping Before piping is connected, it should be thoroughly blown out with air (flushing) or washed to remove chips, cutting oil and other debris from inside the pipe. 5. Always tighten threads with the proper tightening torque.

with 12 VDC, 600 or less with 24 VDC Power supply voltage 12 to 24 VDC (ripple 10% or less) Current consumption 20 mA or less (without load) Enclosure IP65 Operating temperature range Operating: 0 to 50C, Stored: 25 to 85C in stock (with no condensation and freezing) Environmental resistance Voltage resistance 1000 VAC for 1 min. between external terminals and case Insulation resistance 50M

300 or less with 12VDC, 600 or less with 24VDC Power supply voltage 12 to 24VDC (ripple 10% or less) Current consumption 20mA or less (without load) Enclosure IP65 Operating temperature range Operating: 0 to 50C, Stored: 25 to 85C in stock (no freeze nor condensation) Environmental resistance Voltage resistance 1000VAC for 1 min between external terminals and case Insulation resistance 50M

If driving a load such as a relay that generates a surge voltage, use a switch with a built-in contact protection circuit or use a contact protection box. 1) For an auto switch without a contact protection circuit, use a contact protection box when the wire length is 50m or longer.

This is a legacy product, and replaced byMDWBF63-150-M9BL MNB CYLINDER WITH FINELOCK . 63MM MNB DBL-ACT AUTO-SW. ACTUATOR. 63MM MNB DBL-ACT AUTO-SW. 13.62456 lb. PE .

This is a legacy product, and replaced byMXH10-15Z-M9BL, CYL, COMPACT SLIDE TABLE *LQA, ACTUATOR, 10MM MXU DBL-ACT AUTO-SW, .50540 lb

This is a legacy product, and replaced byCY1SG25-500BZ-M9BL, CYL, RODLESS, SLIDER, SW CAP, ACTUATOR, CY1S GUIDED CYLINDER, IM, 25MM CY1S SLIDE BEARING, 7.73454 lb

This is a legacy product, and replaced byMKB32-10LZ-M9BL

Vacuum Valve, Application: Single Item Operating, Installation Method: Direct, Number of Ports: 2-Port Valve, Switching Type: 2-Position Normally Closed, Piping Opening: Flange, Flange Type: NW, Flange Size Nominal: 40, Seal Type: Bellows Seal, Valve Type: Angle type, Indicator: With indicator, Pilot Port Direction: Flange surface, left, Temperature Range(°C): 5 to 60, Switch Part Number: D-M9BL

Vacuum Valve, Application: Single Item Operating, Installation Method: Direct, Number of Ports: 2-Port Valve, Switching Type: 2-Position Normally Closed, Piping Opening: Flange, Flange Type: NW, Flange Size Nominal: 50, Seal Type: Bellows Seal, Valve Type: Angle type, Indicator: With indicator, Pilot Port Direction: Flange surface, left, Temperature Range(°C): 5 to 60, Switch Part Number: D-M9BL

Ball Screw Lead: 6mm, Stroke: 50mm, Origin Switch: Yes (Cable Length 0.3m), Auto Switch: M9BL--Solid State, Gen. Purpose, 2 Wire, Horizontal, 3M, Quantity 1: 2 pcs.

Ball Screw Lead: 12mm, Stroke: 75mm, Origin Switch: Yes (Cable Length 0.3m), Auto Switch: M9BL--Solid State, Gen. Purpose, 2 Wire, Horizontal, 3M, Quantity 1: 4 pcs.

Ball Screw Lead: 6mm, Stroke: 100mm, Origin Switch: Yes (Cable Length 0.3m), Auto Switch: M9BL--Solid State, Gen. Purpose, 2 Wire, Horizontal, 3M, Quantity 1: 3 pcs.