Compatible Fluid: Chemical, Operating Environment: Standard, Type: Air Operating Type, Number of Solenoids: Single Solenoid, Switching Type: Normally Closed, Application: Individual Item, Connection Type: Tube Connection, Tube Diameter: φ6.35, Operating Temperature Range(°C): 0~60, Driving Type: Pilot Type, Operating Pressure Difference Range(MPa): 0.3~0.5, Orifice Diameter(Ø): 4, Option:
Compatible Fluid: Vacuum / Chemical, Operating Environment: Standard, Type: Air Operating Type, Number of Solenoids: Single Solenoid, Switching Type: Normally Closed, Application: Individual Item, Connection Type: Tube Connection, Tube Diameter: φ6.35, Operating Temperature Range(°C): 0~60, Driving Type: Pilot Type, Operating Pressure Difference Range(MPa): 0.3~0.5, Orifice Diameter(Ø): 8
Compatible Fluid: Vacuum / Chemical, Operating Environment: Standard, Type: Air Operating Type, Number of Solenoids: Single Solenoid, Switching Type: Normally Open, Application: Individual Item, Connection Type: Tube Connection, Tube Diameter: φ6.35, Operating Temperature Range(°C): 0~60, Driving Type: Pilot Type, Operating Pressure Difference Range(MPa): 0.3~0.5, Orifice Diameter(Ø): 8,
Body Class: 3 (Orifice Dia. ø8), Valve Type: 2 (Double Acting), Applicable Tubing Size: 07 (1/4"), Port B (OUT) Different Dia. Size: Ports A & B Same Size, Pilot Port Thread Type: One Touch Fitting Class 1: ø4, Class 2~5: ø6, Pilot Port Position: None (Position 1), Material: Standard, Option: 1 (With Flow Rate Adjustment)
This is a legacy product. Please contact us for the latest version.sales@ocaire.com VALVE. VALVE. FLUOROPOLYMER. .00000 lb.
LVH series air operated high purity valves are corrosion resistant against acid, alkali and ultra pure water, making the LVH valve the perfect answer to overcome the harsh environments often encountered in wet process applications. Series LVH is a manually operated valve, available in a threaded or integral fitting type.Manually operated, integral fitting valve, Body class: 2 (?4 orifice
Body Class: 2 (Orifice Dia. ø4), Valve Type: 0 (N.C.), Applicable Tubing Size: 07 (1/4"), Port B (OUT) Different Dia. Size: Ports A & B Same Size, Pilot Port Thread Type: One Touch Fitting Class 1: ø4, Class 2~5: ø6, Pilot Port Position: None (Position 1), Material: N (Ammonium Hydroxide Compatible), Option: 1 (With Flow Rate Adjustment)
Body Class: 2 (Orifice Dia. ø4), Valve Type: 0 (N.C.), Applicable Tubing Size: 07 (1/4"), Port B (OUT) Different Dia. Size: Ports A & B Same Size, Pilot Port Thread Type: One Touch Fitting Class 1: ø4, Class 2~5: ø6, Pilot Port Position: None (Position 1), Material: Standard, Option: 1 (With Flow Rate Adjustment)
Body Class: 2 (Orifice Dia. ø4), Valve Type: 1 (N.O.), Applicable Tubing Size: 07 (1/4"), Port B (OUT) Different Dia. Size: Ports A & B Same Size, Pilot Port Thread Type: One Touch Fitting Class 1: ø4, Class 2~5: ø6, Pilot Port Position: None (Position 1), Material: N (Ammonium Hydroxide Compatible)
Body Class: 2 (Orifice Dia. ø4), Valve Type: 0 (N.C.), Applicable Tubing Size: 07 (1/4"), Port B (OUT) Different Dia. Size: Ports A & B Same Size, Pilot Port Thread Type: One Touch Fitting Class 1: ø4, Class 2~5: ø6, Pilot Port Position: None (Position 1), Material: N (Ammonium Hydroxide Compatible)
Body Class: 3 (Orifice Dia. ø8), Valve Type: 0 (N.C.), Applicable Tubing Size: 07 (1/4"), Port B (OUT) Different Dia. Size: Ports A & B Same Size, Pilot Port Thread Type: One Touch Fitting Class 1: ø4, Class 2~5: ø6, Pilot Port Position: None (Position 1), Material: Standard, Option: 2 (With By-Pass)
This product is obsolete. Please contact us for the latest version.sales@ocaire.com VALVE. VALVE. FLUOROPOLYMER. .21087 lb.
LVH series air operated high purity valves are corrosion resistant against acid, alkali and ultra pure water, making the LVH valve the perfect answer to overcome the harsh environments often encountered in wet process applications. Series LVH is a manually operated valve, available in a threaded or integral fitting type.Manually operated, integral fitting valve, Body class: 2 ( 4 orifice
Body Class: 2 (Orifice Dia. ø4), Valve Type: 0 (N.C.), Applicable Tubing Size: 07 (1/4"), Port B (OUT) Different Dia. Size: Ports A & B Same Size, Pilot Port Thread Type: One Touch Fitting Class 1: ø4, Class 2~5: ø6, Pilot Port Position: None (Position 1), Material: Standard, Option: 2 (With By-Pass)
Body Class: Class 2, Stations: 2 Stations, Tubing Size-P Port/L Conn.: 1/4, Tubing Size-P Port/R Conn.: -
Body Class: Class 2, Stations: 3 Stations, Tubing Size-P Port/L Conn.: 1/4, Tubing Size-P Port/R Conn.: -
Body Class: Class 2, Stations: 4 Stations, Tubing Size-P Port/L Conn.: 1/4, Tubing Size-P Port/R Conn.: -
Body Class: Class 2, Stations: 5 Stations, Tubing Size-P Port/L Conn.: 1/4, Tubing Size-P Port/R Conn.: -
Body Class: Orifice ø4, Valve Type: Normally Closed, Tube Size: 1/4", Pilot Port: Body Class 2 - M5 Thread; Body Class 3, 4, 5 - Rc1/8, Material: Body PFA, Actuator Endplate PPS, Diaphragm PTFE, Option: Flow Rate Adjustment
Body Class: Orifice ø4, Valve Type: Normally Open, Tube Size: 1/4", Pilot Port: Body Class 2 - M5 Thread; Body Class 3, 4, 5 - Rc1/8, Material: Body PFA, Actuator Endplate PPS, Diaphragm PTFE, Option: Flow Rate Adjustment