Body Class: Orifice Diameter ø10, Valve Type: Normally Closed, Applicable Tube OD: 1/2, Port B OUT: Ports A & B Same Size, Pilot Port: Body Class 2 - M5 Thread; Body Class 3, 4, 5, 6 - Rc1/8, Material: Body: PFA, Actuator Endplate: PPS, Diaphragm: PTFE, Option: Indicator, Specification: -, Z: -

Body Class: Orifice Dia. ø10, Valve Type: N.C., Applicable Tubing Size: 1/2", Port B (OUT) Different Dia. Size: Ports A & B Same Size, Pilot Port Thread Type: One Touch Fitting Class 1: ø4, Class 2~5: ø6, Pilot Port Position: None (Position 1), Material: Standard, Option: With Flow Rate Adjustment

Body Class: Orifice Dia. ø10, Valve Type: N.C., Applicable Tubing Size: 1/2", Port B (OUT) Different Dia. Size: Ports A & B Same Size, Pilot Port Thread Type: One Touch Fitting Class 1: ø4, Class 2~5: ø6, Pilot Port Position: None (Position 1), Material: Ammonium Hydroxide Compatible, Option: -

Body Class: Orifice Dia. ø10, Valve Type: N.C., Applicable Tubing Size: 1/2", Port B (OUT) Different Dia. Size: Ports A & B Same Size, Pilot Port Thread Type: One Touch Fitting Class 1: ø4, Class 2~5: ø6, Pilot Port Position: None (Position 1), Material: Ammonium Hydroxide Compatible, Option: With Flow Rate Adjustment

Body Class: ø10 Orifice, Valve Type: N.C., Fitting Type: LQ2 Body Class: 2, 3, 4, 5, Fitting Size: Tubing O.D. 1/2, Pilot Port Thread: LQ1 Integral Fitting, 1/8" (3mm), Pilot Port Direction: Direction 1, Option 1: Flow Rate Adjustment, Option 2: -

Body Class: ø10 Orifice, Valve Type: N.C., Fitting Type: LQ2 Body Class: 2, 3, 4, 5, Fitting Size: Tubing O.D. 1/2, Pilot Port Thread: LQ1 Integral Fitting, 1/8" (3mm), Pilot Port Direction: Direction 1, Option 1: Indicator, Option 2: -

Body Class: ø10 Orifice, Valve Type: N.C., Fitting Type: LQ2, Body Class: 2, 3, 4, 5, Tube Size: 1/2", Output Tube Size: None, Pilot Connection: LQ1 Integral Fitting, 1/8" (3mm), Pilot Port Direction: Direction 1, Option 1: None, Option 2: for High Temperature

Body Class: ø10 Orifice, Valve Type: N.C., Fitting Type: LQ2, Body Class: 2, 3, 4, 5, Tube Size: 1/2", Output Tube Size: None, Pilot Connection: LQ1 Integral Fitting, 1/8" (3mm), Pilot Port Direction: Direction 1, Option 1: Flow Rate Adjustment, Option 2: -

Body Class: ø10 Orifice, Valve Type: N.C., Fitting Type: LQ2, Body Class: 2, 3, 4, 5, Tube Size: 1/2", Output Tube Size: None, Pilot Connection: LQ1 Integral Fitting, 1/8" (3mm), Pilot Port Direction: Direction 1, Option 1: High Back Pressure w/Flow Rate Adjustment, Option 2: -

Body Class: ø10 Orifice, Valve Type: N.C., Fitting Type: LQ2, Body Class: 2, 3, 4, 5, Tube Size: 1/2", Output Tube Size: None, Pilot Connection: LQ1 Integral Fitting, 1/8" (3mm), Pilot Port Direction: Direction 1, Option 1: High Back Pressure w/By-pass, Option 2: -

Body Class: ø10 Orifice, Valve Type: N.C., Fitting Type: LQ2, Body Class: 2, 3, 4, 5, Tube Size: 1/2", Output Tube Size: None, Pilot Connection: LQ1 Integral Fitting, 1/8" (3mm), Pilot Port Direction: Direction 1, Option 1: High Back Pressure w/Flow Rate Adjustment & By-pass, Option 2: -

Body Class: ø10 Orifice, Valve Type: N.C., Fitting Type: LQ2, Body Class: 2, 3, 4, 5, Tube Size: 1/2", Output Tube Size: None, Pilot Connection: LQ1 Integral Fitting, 1/8" (3mm), Pilot Port Direction: Direction 1, Option 1: High Back Pressure w/Indicator, Option 2: -

Body Class: ø10 Orifice, Valve Type: N.C., Fitting Type: LQ2, Body Class: 2, 3, 4, 5, Tube Size: 1/2", Output Tube Size: None, Pilot Connection: LQ1 Integral Fitting, 1/8" (3mm), Pilot Port Direction: Direction 1, Option 1: Flow Rate Adjustment & By-pass, Option 2: -

Body Class: ø10 Orifice, Valve Type: N.C., Fitting Type: LQ2, Body Class: 2, 3, 4, 5, Tube Size: 1/2", Output Tube Size: None, Pilot Connection: LQ1 Integral Fitting, 1/8" (3mm), Pilot Port Direction: Direction 1, Option 1: High Back Pressure, 0.42 MPa, Option 2: -

High purity chemical valves, series LVC with integral fittings eliminate the possibility of residual liquid in pipe threads. In addition, the body has been designed for smooth flow with minimal internal dead space. Special diaphragm construction insures gentle opening and closing preventing the formation of micro-bubbles. A unique guide ring on the piston rod eliminates lateral motion of

LVH series air operated high purity valves are corrosion resistant against acid, alkali and ultra pure water, making the LVH valve the perfect answer to overcome the harsh environments often encountered in wet process applications. Series LVH is a manually operated valve, available in a threaded or integral fitting type.Manually operated, integral fitting valve, Body class: 2 ( 4 orifice

This is a legacy product. Please contact us for the latest version.sales@ocaire.com VALVE RSTRCTD. VALVE. FLUOROPOLYMER. .00000 lb.

Series LVQ is a 2 port chemical valve with a non-metallic exterior. A high density PVDF housing offers increased chemical resistance and the special diaphragm construction insures gentle opening and closing preventing the formation of micro-bubbles. The LVQ guide ring eliminates lateral motion of the poppet, which reduces internal leakage.2 port chemical valve, Viper series (standard type

Body Class: 4 (Orifice Diameter ø10), Valve Type: 0 (Normally Closed), Applicable Tube OD: 13 (1/2), Port B OUT: Ports A & B Same Size, Pilot Port: Body Class 2 - M5 Thread; Body Class 3, 4, 5, 6 - Rc1/8, Material: Body PFA, Actuator Endplate PPS, Diaphragm PTFE, Option: 4 (Indicator), Specification: V (Vacuum)

Body Class: Orifice Diameter ø10, Valve Type: Normally Closed, Applicable Tube OD: 1/2, Port B OUT: Ports A & B Same Size, Pilot Port: Body Class 2 - M5 Thread; Body Class 3, 4, 5, 6 - Rc1/8, Material: Body PFA, Actuator Endplate PPS, Diaphragm PTFE, Option: Indicator, Specification: Vacuum, Z: -