Model: 20 (1500 L/min), Pressure Range: 5 (0.005~0.9MPa), Power Voltage: 0 (24VDC), Input Signal: 0 (Current Style 4~20mADC), Monitor Output: 4 (Analog Output 4~20mA Sink Requires a Sourcing Type Analog Input Module), Thread: F [G(PF)], Port Size: 2 [1/4 (1000,2000,3000)], Accessory: None, Cable Connector: L (Right Angle Style 3m), Pressure Display Unit: MPa, Options: X256 (Analog Current

Model: 20 (1500 L/min), Pressure Range: 5 (0.005~0.9MPa), Power Voltage: 0 (24VDC), Input Signal: 0 (Current Style 4~20mADC), Monitor Output: 4 (Analog Output 4~20mA Sink Requires a Sourcing Type Analog Input Module), Thread: N (NPT), Port Size: 2 [1/4 (1000,2000,3000)], Accessory: None, Cable Connector: N (w/oCable Connector), Pressure Display Unit: 4 (PSI), Options: X256 (Analog Current

Model: 10 (200 L/min [ANR]), Pressure Range: 3 (0.005~0.5MPa), Power Voltage: 0 (24VDC), Input Signal: 0 (Current Style 4~20mADC), Monitor Output: 4 (Analog Output 4~20mA Sink Requires a Sourcing Type Analog Input Module), Thread: N (NPT), Port Size: 2 [1/4 (1000,2000,3000)], Accessory: None, Cable Connector: N (w/oCable Connector), Pressure Display Unit: 4 (PSI), Options: X256 (Analog Current

Model: 30 (4000 L/min), Pressure Range: 5 (0.005~0.9MPa), Power Voltage: 0 (24VDC), Input Signal: 0 (Current Style 4~20mADC), Monitor Output: 4 (Analog Output 4~20mA Sink Requires a Sourcing Type Analog Input Module), Thread: F [G(PF)], Port Size: 3 [3/8 (2000,3000)], Accessory: None, Cable Connector: N (w/oCable Connector), Pressure Display Unit: 3 (Bar), Options: X256 (Analog Current Output

Model: 10 (200 L/min [ANR]), Pressure Range: 5 (0.005~0.9MPa), Power Voltage: 0 (24VDC), Input Signal: 0 (Current Style 4~20mADC), Monitor Output: 4 (Analog Output 4~20mA Sink Requires a Sourcing Type Analog Input Module), Thread: Rc(PT), Port Size: 2 [1/4 (1000,2000,3000)], Accessory: None, Cable Connector: N (w/oCable Connector), Pressure Display Unit: 4 (PSI), Options: X256 (Analog Current

This is a legacy product. Please contact us for the latest version.sales@ocaire.com

Size: 2 (200), Piping and Mounting: 0 (Side Ported Body Mount), No.of Positions: 0 (3 Position Closed Center), Thread: N (NPT), Port Size: 02 (1/4)

Size: 2 (200), Piping and Mounting: 0 (Side Ported Body Mount), No.of Positions: 0 (3 Position Closed Center), Thread: F [G(PF)], Port Size: 02 (1/4)

Main Body Shape: Block Horizontal Type, Number of Ports: 4-Port, Number of Switching Positions: 3-Position Closed Center, Operation Status Retention: Retention, Switching Operation: Manual Lever, Effective Sectional Area(mm2): 10.15, Effective Sectional Area Class(mm2): Up to 15, Pipe Port Type: G, Plumbing Thread Nominal: 1/4, Mounting Method: Bottom, Plumbing Type

Main Body Shape: Block Horizontal Type, Number of Ports: 4-Port, Number of Switching Positions: 3-Position Closed Center, Operation Status Retention: Retention, Switching Operation: Manual Lever, Effective Sectional Area(mm2): 10.15, Effective Sectional Area Class(mm2): Up to 15, Pipe Port Type: NPT, Plumbing Thread Nominal: 1/4, Mounting Method: Bottom, Plumbing Type

Size: 2 (200), Piping and Mounting: 0 (Side Ported Body Mount), No.of Positions: 0 (3 Position Closed Center), Thread: N (NPT), Port Size: 02 (1/4), Rod Handle: R (Handle Position 180° Change)

Size: 2 (200), Piping and Mounting: 0 (Side Ported Body Mount), No.of Positions: 0 (3 Position Closed Center), Thread: F [G(PF)], Port Size: 02 (1/4), Rod Handle: R (Handle Position 180° Change)

Size: 200, Piping and Mounting: Side Ported Body Mount, No.of Positions: 3 Position Closed Center, Thread: F [G(PF)], Port Size: 1/4, Rod Handle: Handle Position 180° Change, Made to Order: -

Main Body Shape: Block Horizontal Type, Number of Ports: 4-Port, Number of Switching Positions: 3-Position Closed Center, Operation Status Retention: Retention, Switching Operation: Manual Lever, Effective Sectional Area(mm2): 10.15, Effective Sectional Area Class(mm2): Up to 15, Pipe Port Type: NPT, Plumbing Thread Nominal: 1/4, Mounting Method: Bottom, Plumbing Type

Series VH rotary hand valve's compact design and variety of flow rates make it ideal for a wide range of applications requiring manual directional control. The slide ring design makes the VH valve easy to operate while offering a high tolerance to contamination with its "self-cleaning, wiping action"., HAND VALVE, VALVE, VH HAND VALVE, FF, VH BODY PT 1/4NPT, .92325 lb

Series VH rotary hand valve's compact design and variety of flow rates make it ideal for a wide range of applications requiring manual directional control. The slide ring design makes the VH valve easy to operate while offering a high tolerance to contamination with its "self-cleaning, wiping action"., HAND VALVE, VALVE, VH HAND VALVE, FF, VH BODY PT 1/4NPT, .99206 lb

Series VH rotary hand valves compact design and variety of flow rates make it ideal for a wide range of applications requiring manual directional control. The slide ring design makes the VH valve easy to operate while offering a high tolerance to contamination with its "self-cleaning, wiping action"., HAND VALVE, REVERSE, VALVE, VH HAND VALVE, FF, VH BODY PT 1/4NPT, 0.92181 lb

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, 3-WAY HAND VALVE, VALVE, VH HAND VALVE, FF, VH BODY PT 1/4NPT, .00000 lb

Series ITV electro-pneumatic and electronic vacuum regulators control air/vacuum pressure steplessly in proportion to an electric signal. They are light weight in design with a bright and easy to read LED display. The monitor output is available either as analog output or switch output. The ITV series is IP65 equivalent.Controls air pressure in proportion to an electric signal., Available

Series ITV electro-pneumatic and electronic vacuum regulators control air/vacuum pressure steplessly in proportion to an electric signal. They are light weight in design with a bright and easy to read LED display. The monitor output is available either as analog output or switch output. The ITV series is IP65 equivalent.Controls air pressure in proportion to an electric signal., Available